Fig. 11
15.1.5 Bias Voltage Check
1. Connect an electrical voltmeter. (Cf. Fig. 9) (Cf. Fig. 12)
2. Set the function to “TAPE” position.
3. Insert a normal blank cassette tape (QZZCRA).
4. While pressing and holding down [REC ( / )] button, press [TAPE ( )] button to pause the recording mode.
(Repeat pressing the buttons till the recording pause mode is activated.)
5. Check that the output level is within the standard range.
Standard Range: 14 ± 4mV
Fig. 12
15.1.6 Bias Frequency Check
1. Connect a digital frequency counter (Figure 13).
2. Set the function to “TAPE” position.
3. Insert a normal blank cassette tape (QZZCRA) and press “REC” mode on main unit.
4. Check that the output frequency is within the standard range.
Fig. 13
Standard Value: 98 ±8 kHz
Содержание SA-PM29P
Страница 10: ...8 Operation Procedures ...
Страница 11: ......
Страница 12: ...9 Information on MP3 WMA ...
Страница 13: ......
Страница 17: ......
Страница 28: ......
Страница 35: ......
Страница 38: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 50: ...11 24 Handling of cassette tape jam z Follow the Step 1 Step 6 of Item 11 2 ...
Страница 51: ......
Страница 60: ...16 Block Diagram 16 1 CD Servo Block 16 2 Main Block ...
Страница 89: ...19 8 Transformer P C B ...
Страница 101: ...20 Wiring Connection Diagram ...
Страница 104: ...21 Illustration of IC s Transistors and Diodes ...
Страница 111: ...23 Troubleshooting Flowchart CD Section Circuit ...
Страница 112: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ...25 Additional Contents 1 25 1 Voltage Measurement ...