Overall frequency reponse (+3, -6
dB at DECK OUT)
NORMAL (TYPE I)
35- Hz - 14 kHz
HIGH (TYPE II)
35- Hz - 14 kHz
S/N
50dB (A weighted)
Wow and flutter
0.18 % (WRMS)
Fast forward and rewind time
Approx. 120 seconds with C-60
cassette tape
■
CD Section
Sampling frequency
44.1kHz
Decoding
16 bit linear
Frequency response
20 Hz - 20 kHz (+1, -2 dB)
Wow and flutter
Below measurable limit
Digit filter
8 fs
D/A converter
MASH (1 bit DAC)
■
General
1
Before Use
2
2
Before Repair and Adjustment
2
3
Protection Circuitry
2
4
Accessories
3
5
Handling Precautions For Traverse Deck
4
6
Precaution of Laser Diode
4
7
Operation Procedures
6
8
Self-Diagnostic Display Function
8
9
Description of Error Code
9
Power supply
AC 110V/127V/220V/230-240V,
50/60Hz
Power consumption
188 W
Standby
ECO
0.8 W
NORMAL
12 W
Dimensions (WxHxD)
270 x 330 x 339 mm
Weight
8.8 kg
Notes :
1. Specifications are subject to change without notices.
Weight and dimensions are approximate.
2. Total harmonic distortion is measured by the digital spectrum
analyzer.
■
System: SC-AK78 (GC)
Music Center : SA-AK78 (GC)
Front Speaker : SB-AK78 (GC)
Center Speaker : SB-PC70 (GC)
Surround Speaker : SB-PS70 (GC)
10 CD Test Mode Function
10
11 Measurements and Adjustments
11
12 Terminal Function of IC’s
13
13 Block Diagram
16
14 Schematic Diagram
26
15 Printed Circuit Board
47
16 Wiring Connection Diagram
57
17 Troubleshooting Guide
59
18 Parts Location and Replacement Parts List
60
CONTENTS
Page
Page
1 Before Use
Be sure to disconnect the mains cord before adjusting the voltage selector. Use a minus (-) screwdriver to set the voltage selector
(on the rear panel) to the voltage setting for the area in which the unit will be used. (If the power supply in your area is 117V or
120V, set to the “127V” position.) Note that this unit will be seriously damaged if this setting is not made correctly. (There is no
voltage selector for some countries; the correct voltage is already set.)
2 Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C566 - C569, C591 through a 10
Ω
, 5W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
• •
Current consumption at AC 110V, 127V, 220V, 230-240V, 50 Hz in NO SIGNAL mode should be ~620mA, ~590mA, ~330mA
and ~300mA respectively.
3 Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
2
SA-AK78
Содержание SA-AK78
Страница 6: ......
Страница 7: ...7 SA AK78 ...
Страница 34: ...34 SA AK78 ...
Страница 57: ...16 Wiring Connection Diagram 57 SA AK78 ...
Страница 58: ...58 SA AK78 ...
Страница 59: ...17 Troubleshooting Guide 59 SA AK78 ...
Страница 61: ...18 1 1 Deck Mechanism Parts Location 18 1 Mecanismo do Deck Montado RD JMD034 Z 61 SA AK78 ...
Страница 62: ...62 SA AK78 ...
Страница 64: ...18 2 CD Loading Mechanism RD DAC024 Z 18 2 1 CD Loading Mechanism Parts Location 64 SA AK78 ...
Страница 65: ......
Страница 67: ...18 3 1 Cabinet Parts Location 18 3 Cabinet 67 SA AK78 ...
Страница 68: ...68 SA AK78 ...
Страница 69: ......