No.
Abnormal Items
Error
Display
Method of Detection
1
REST SW abnormal
F15
Under normal operation (Self-Diagnostic Mode
inclusive), this error occurs when the REST SW
not detected within the specified time and shall
memorized.
2
Transmission error between
CD servo LSI and micon
F26
Under normal operation (Self-Diagnostic Mode
inclusive), this error occurs when the selection
to CD and SENSE=’H’ is detected and SENSE=’L’
detected within a fail safe time (20ms) after system
command transmission was sent.
3
CLAMP SW abnormal
F16
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-0A error is detected.
4
BOTTOM SW abnormal
F17
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-09 error is detected.
5
POSITION SW abnormal
F27
Refer tp CR20 control specification section 5-2
[ERROR CODE] table M-05 ~ M-08 error is detected.
6
SW1 abnormal
F28
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-02 ~ M-08 error is detected.
7
SW2 abnormal
F29
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-02 ~ M-08 error is detected.
8
OPEN SW abnormal
H15
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-01 error is detected.
12.3. Power Supply related error detection
No.
Abnormal Items
Error
Display
Method of Detection
1
POWER AMP output
abnormal
F61
During normal operation, if DCDET 1/2 becomes
normal POWER OFF process shall not be executed,
PCNT shall be switched to ‘L’ immediately. GOODBYE
shall not be displayed and the error display F61
displayed instead.
2 seconds after the F61 display, ECONO shall be
‘L’ and FL display shall be turned off.
The error content shall be memorized when the
abnormality occurs and can be displayed in the
mecha self-diagnostic mode described later.
13. Self-Diagnostic Function
13.1. Self-diagnostic display
This unit is equipped with a self-diagnostic display function which, if a problem occurs, will
display an error code corresponding to the problem.
Use this function when performing maintenance on the unit.
13.2. How to enter the Self-Diagnostic Function
60
Содержание SA-AK520E
Страница 10: ...8 Accessories Remote Control Transmitter FM Indoor Antenna AC Power Supply Cord For E EG ony 10 ...
Страница 13: ... Disassembly of Rear Panel Step 3 Remove 8 screws Step 4 Detach wire at CN305 Fan 13 ...
Страница 84: ...23 Parts Location and Replacement Parts List Notes 84 ...
Страница 87: ...87 ...
Страница 88: ...23 1 2 Deck Mechanism Parts List 88 ...
Страница 90: ...90 ...
Страница 91: ...23 2 2 CD Loading Mechanism Parts List 91 ...
Страница 94: ...94 ...
Страница 95: ...95 ...
Страница 96: ...23 3 2 Cabinet Parts List 96 ...
Страница 125: ...PRT0401 D K J N L 125 ...
Страница 158: ......