Panasonic S-LINK V Скачать руководство пользователя страница 7

7

1) HML0 + 00 to HML0 + 3F: Data area

Relationship between “Computer I/O address” and “S-LINK V address”

Computer I/O address

(hexadecimal)

S-LINK V

 address

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

HML0 + 00

7

6

5

4

3

2

1

0

HML0 + 01

15

14

13

12

11

10

9

8

HML0 + 02

23

22

21

20

19

18

17

16

HML0 + 03

31

30

29

28

27

26

25

24

HML0 + 04

39

38

37

36

35

34

33

32

HML0 + 05

47

46

45

44

43

42

41

40

HML0 + 06

55

54

53

52

51

50

49

48

HML0 + 07

63

62

61

60

59

58

57

56

HML0 + 08

71

70

69

68

67

66

65

64

HML0 + 09

79

78

77

76

75

74

73

72

HML0 + 0A

87

86

85

84

83

82

81

80

HML0 + 0B

95

94

93

92

91

90

89

88

HML0 + 0C

103

102

101

100

99

98

97

96

HML0 + 0D

111

110

109

108

107

106

105

104

HML0 + 0E

119

118

117

116

115

114

113

112

HML0 + 0F

127

126

125

124

123

122

121

120

HML0 + 10

135

134

133

132

131

130

129

128

HML0 + 11

143

142

141

140

139

138

137

136

HML0 + 12

151

150

149

148

147

146

145

144

HML0 + 13

159

158

157

156

155

154

153

152

HML0 + 14

167

166

165

164

163

162

161

160

HML0 + 15

175

174

173

172

171

170

169

168

HML0 + 16

183

182

181

180

179

178

177

176

HML0 + 17

191

190

189

188

187

186

185

184

HML0 + 18

199

198

197

196

195

194

193

192

HML0 + 19

207

206

205

204

203

202

201

200

HML0 + 1A

215

214

213

212

211

210

209

208

HML0 + 1B

223

222

221

220

219

218

217

216

HML0 + 1C

231

230

229

228

227

226

225

224

HML0 + 1D

239

238

237

236

235

234

233

232

HML0 + 1E

247

246

245

244

243

242

241

240

HML0 + 1F

255

254

253

252

251

250

249

248

HML0 + 20

263

262

261

260

259

258

257

256

HML0 + 21

271

270

269

268

267

266

265

264

HML0 + 22

279

278

277

276

275

274

273

272

HML0 + 23

287

286

285

284

283

282

281

280

HML0 + 24

295

294

293

292

291

290

289

288

HML0 + 25

303

302

301

300

299

298

297

296

HML0 + 26

311

310

309

308

307

306

305

304

HML0 + 27

319

318

317

316

315

314

313

312

HML0 + 28

327

326

325

324

323

322

321

320

HML0 + 29

335

334

333

332

331

330

329

328

HML0 + 2A

343

342

341

340

339

338

337

336

HML0 + 2B

351

350

349

348

347

346

345

344

HML0 + 2C

359

358

357

356

355

354

353

352

HML0 + 2D

367

366

365

364

363

362

361

360

HML0 + 2E

375

374

373

372

371

370

369

368

HML0 + 2F

383

382

381

380

379

378

377

376

HML0 + 30

391

390

389

388

387

386

385

384

HML0 + 31

399

398

397

396

395

394

393

392

HML0 + 32

407

406

405

404

403

402

401

400

HML0 + 33

415

414

413

412

411

410

409

408

HML0 + 34

423

422

421

420

419

418

417

416

HML0 + 35

431

430

429

428

427

426

425

424

HML0 + 36

439

438

437

436

435

434

433

432

HML0 + 37

447

446

445

444

443

442

441

440

HML0 + 38

455

454

453

452

451

450

449

448

Содержание S-LINK V

Страница 1: ...2018 3 panasonic net id pidsx global Flexible Wire saving Link S LINK V PCI Bus S LINK V Control Board SL VPCI Instruction Manual CMJE SLVPCI No 0062 88V...

Страница 2: ...e Take care that wrong wiring will damage the product Wiring This product has been developed produced for industrial use only In case noise generating equipment switching regulator inverter motor etc...

Страница 3: ...Remarks 7 F G Frame ground 6 24V External power supply input 5 0V 4 24V Brown 3 0V Blue 2 D White 1 G Black Tightening torque of the terminal screws 0 5 to 0 6 N m Terminal block connector MSTB2 5 7 S...

Страница 4: ...nts ON OFF OFF OFF 320 points ON OFF OFF ON 352 points ON OFF ON OFF 384 points ON OFF ON ON 416 points ON ON OFF OFF 448 points ON ON OFF ON 480 points ON ON ON OFF 512 points ON ON ON ON ON 1 7 8 5...

Страница 5: ...during no transmission Blinking interval differs depending on the transmission speed A mode Fast C mode Slow 7 Busy indicator Orange It lights up during the system setting or transmission process con...

Страница 6: ...6 S LINK V I O unit connected node number R HML0 47 Not usable 04 HML0 48 Error No Error state R HML0 49 Command execution request register Communication frame confirmation Error No clear Default Syst...

Страница 7: ...2 HML0 19 207 206 205 204 203 202 201 200 HML0 1A 215 214 213 212 211 210 209 208 HML0 1B 223 222 221 220 219 218 217 216 HML0 1C 231 230 229 228 227 226 225 224 HML0 1D 239 238 237 236 235 234 233 23...

Страница 8: ...s the first address of the affected S LINK V I O unit is indicated When each bit is 1 output of S LINK V output unit of the address short circuits or the I O driv ing power breaks down In case Bank ch...

Страница 9: ...data area to the information corresponding to the bank number SL VPCI The internal circuit switches to the bank change over response register and then writes in the bank number User s computer It read...

Страница 10: ...on When setting is done by a program I Os can be set in units of 16 In this case set all the I O set ting switches to input 0 ON If the change is done by program it is automatically changed within 1 t...

Страница 11: ...rval shorter than the S LINK V system response delay time the data may not be transmitted After the output data is written if 1 is written into HML0 49 bit 0 and the next output data is written in aft...

Страница 12: ...an interruption occurrence Only clearance of the interruption can be carried out 1 0 1 0 Command execution request register Command completion response register The order of priority for each command...

Страница 13: ...In case bit 1 is 1 an interruption occurs and in case it is 0 an interruption does not occur If the input change interruption is effective an interruption occurs when the input signal of S LINK V inp...

Страница 14: ...ntents of error check by 5 HML0 48 Error No Error state Occurrence Interruption Error In order to clear the interruption 6 Command execution request register 7 Command completion response register are...

Страница 15: ...ency 0 75mm amplitude in X Y and Z directions for two hours each Shock resistance Note 5 98m s2 acceleration approx 10G in X Y and Z directions for three times each Grounding method Bracket Floating S...

Страница 16: ...practice at the time of purchase or contract 4 Failure caused by use which deviates from the conditions environment given in the product catalogue or specifications 5 In case this product is used by...

Отзывы: