Precautions for Use

Installation

This air conditioner must be installed properly by quali

fi

 ed 

installation technicians in accordance with the Installation 

Instructions provided with the unit.

Before installation, check that the voltage of the electric sup-

ply in your home or of

fi

 ce is the same as the voltage shown 

on the nameplate.

WARNING

Avoid the following locations for installation.

Locations where smoke or combustible gas exists.

Also locations of extremely high temperature such as a 

greenhouse.

Locations where excessively high heat-generating ob-

jects are placed.

Attention:

Avoid installing the outdoor unit where salty sea water can 

splash directly onto it or in sulphurous air near a spa.

(To protect the air conditioner from heavy corrosion)

Wiring

All wiring must conform to the local electrical codes.

(Consult your dealer or a quali

fi

 ed electrician for details.)

Each unit must be properly grounded with a ground (or 

earth) wire or through the supply wiring.

Wiring must be done by a quali

fi

 ed electrician.

Operation Preparation

Turn the power mains on 5 hours before 

the start of operation.

(For warm-up)

Leave the power mains ON for continuous use.

ON

NOTE

Pull off the power plug from a receptacle, or switch off the 

breaker, or switch off the power disconnecting mean to isolate 

the air conditioner from the main power supply when not in use 

for a long time.

Operation Condition

Use this air conditioner under the following temperature range.

 

Indoor temperature range:

Cooling mode  14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT)

Heating mode  16°C ~ 30°C (*DBT)

 

Outdoor temperature range:

Cooling mode  -15°C ~ 46°C (*DBT)

Heating mode  -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT)

*DBT: Dry bulb temperature

*WBT: Wet bulb temperature

Information for Users on Collection and Disposal of 
Old Equipment and Used Batteries

[Information on Disposal in other Countries 

outside the European Union] 

These symbols are only valid in the European 

Union. If you wish to discard these items, 

please contact your local authorities or dealer 

and ask for the correct method of disposal.

Pb

Note for the battery symbol (bottom two 

symbol examples):

This symbol might be used in combination with 

a chemical symbol. In this case it complies 

with the requirement set by the Directive for 

the chemical involved.

00_P07-T11600A_YS0214-0.indb   4

00_P07-T11600A_YS0214-0.indb   4

3/5/2014   2:00:56 PM

3/5/2014   2:00:56 PM

  04/11/2016

Содержание S-60PE1R5A

Страница 1: ...Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan P07 T11600A Ducted E1 type Model No INDOOR UNIT Ducted Type S 60PE1R5A S 71PE1R5A S 100PE1R5A S 125PE1R5A S 140PE1R5A OUTDOOR UNIT Single Split Single phase PE1 Type U 60PE1R5A U 71PE1R5A U 100PE1R5A U 125PE1R5A U 140PE1R5A Single Split 3 phase PE1 Type U 100PE1R8A U 125PE1R8A U 140PE1R8A 04 11 2016 ...

Страница 2: ...hands Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Refrigerant gas leakage may cause fire For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isol...

Страница 3: ... insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips frequently The product sometimes does no...

Страница 4: ...n Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under the foll...

Страница 5: ... operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically DRY oper...

Страница 6: ...ogged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperature settings See Tips for Energy Saving The room is exposed to direct sunlight in cooling mode Doors or windows are open The air filter is clogged See Maintenance Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in c...

Страница 7: ...nger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is rotating for a while even though operation stops Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Dust is discharged Dust accumulated inside the indoor unit is discharged At the initial high speed operation the fan sometimes rotat...

Страница 8: ...site http panasonic net Printed in China Panasonic Corporation 2014 P07 T11600A YS0214 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 04 11 2016 ...

Отзывы: