This appliance is intended to be used 

by expert or trained users in shops,in 

light industry and on farms, or for 

commercial use by lay persons.
This air conditioner has no ventilator 

for intaking fresh air from outdoors. 

You must open doors or windows 

frequently when you use gas or 

oil heating appliances in the same 

room, which consume a lot of oxygen 

from the air. Otherwise there is a risk 

of suffocation in an extreme case.
Keep the 

fi

 re alarm and the air outlet 

at least 1.5m away from the unit.
Do not cool or heat the room too 

much if babies or invalids are 

present.
Do not turn the air conditioner on 

and off from the power mains switch. 

Use the ON/OFF operation button.
Do not stick anything into the air 

outlet of the outdoor unit. This 

is dangerous because the fan 

is rotating at high speed.
Do not touch the air inlet or the 

sharp aluminum 

fi

 ns of the 

outdoor unit. You may get 

injured.
Do not stick any object 

into the FAN CASE. You 

may be injured and the 

unit may be damaged.

Provide a power outlet to be 

used exclusively for each unit, 

and a power supply disconnect, 

circuit breaker and earth leakage 

breaker for overcurrent protection 

should be provided in the 

exclusive line.
Provide a power outlet 

exclusively for each unit, and full 

disconnection means having a 

contact separation in all poles 

must be incorporated in the 

fi

 xed 

wiring in accordance with the 

wiring rules.
To prevent possible hazards 

from insulation failure, the 

unit must be grounded.
Do not use modi

fi

 ed 

cord, joint cord, 

extension cord or 

unspeci

fi

 ed cord to prevent 

overheating and 

fi

 re. 

Stop using the product when any 

abnormality/failure occurs and 

disconnect the power plug or turn 

off the power switch and breaker.

(Risk of smoke/

fi

 re/electric shock)

Examples of abnormality/failure:

• The ELCB trips frequently.

• The product sometimes does not 

start when turned on.

• The power is sometimes disconnected 

when the cord is moved.

• Burnt odor or abnormal noise is 

detected during operation.

• The body is deformed or 

abnormally hot.

• Water leaks from the indoor unit.

• Power cord or plug becomes 

abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running 

immediately even if it is switched 

on for operation.

• The fan does not stop even if the 

operation is stopped.

Contact immediately your local 

dealer for maintenance/repair.

Do not sit or step on the unit. 

You may fall down accidentally.

CAUTION

• The compressor may occasionally stop during thunderstorms.

This is not a mechanical failure. The unit automatically 

recovers after a few minutes.

• The English text is the original instructions. Other languages 

are translation of the original instructions.

Important Information Regarding

The Refrigerant Used

This product contains 

fl

 uorinated greenhouse gases covered 

by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
GWP

(1)

 value: 1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required 

depending on European or local legislation. Please contact 

your local dealer for more information.

NOTICE

00_P07-T11600A_YS0214-0.indb   3

00_P07-T11600A_YS0214-0.indb   3

3/5/2014   2:00:55 PM

3/5/2014   2:00:55 PM

  04/11/2016

Содержание S-60PE1R5A

Страница 1: ...Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan P07 T11600A Ducted E1 type Model No INDOOR UNIT Ducted Type S 60PE1R5A S 71PE1R5A S 100PE1R5A S 125PE1R5A S 140PE1R5A OUTDOOR UNIT Single Split Single phase PE1 Type U 60PE1R5A U 71PE1R5A U 100PE1R5A U 125PE1R5A U 140PE1R5A Single Split 3 phase PE1 Type U 100PE1R8A U 125PE1R8A U 140PE1R8A 04 11 2016 ...

Страница 2: ...hands Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Refrigerant gas leakage may cause fire For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isol...

Страница 3: ... insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips frequently The product sometimes does no...

Страница 4: ...n Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under the foll...

Страница 5: ... operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically DRY oper...

Страница 6: ...ogged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperature settings See Tips for Energy Saving The room is exposed to direct sunlight in cooling mode Doors or windows are open The air filter is clogged See Maintenance Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in c...

Страница 7: ...nger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is rotating for a while even though operation stops Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Dust is discharged Dust accumulated inside the indoor unit is discharged At the initial high speed operation the fan sometimes rotat...

Страница 8: ...site http panasonic net Printed in China Panasonic Corporation 2014 P07 T11600A YS0214 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 04 11 2016 ...

Отзывы: