2. Press
RC
ADR
to select the address of the receiver you want to
control, and press
.
•
Every time you press
RC
ADR
, it cycles from “ALL (All the addresses)
→
1
→
2
→
3
→
4
→
5
→
6”.
•
If it corresponds to the receiver’s address setting, the buzzer sounds.
Note
•
Set the address of the receiver as instructed in the operating instructions of your
receiver. Do not set by yourself. Contact the dealer where the product was
purchased.
■
For wall mounted type indoor unit
< Setting the address of the indoor unit >
1. Press [Emergency Operation] of the indoor unit for 4 seconds or longer.
• OPERATION lamp, TIMER lamp, and then STANDBY lamp repeatedly light one after the other for 1 second
each to indicate the unit is ready for address setting.
Checking Addresses
1. Press with one end of an unfolded paper clip
(or a similar object that can fit).
• Its current address appears on the display for 5 seconds.
• If this address corresponds to the address of a receiver, the buzzer
sounds. (If it is on ALL, the buzzer will always sound.)
• If it is on ALL, it can be operated regardless of receiver addresses.
Point the remote controller at the receiver you wish to operate and
transmit.
RC
ADR
Matching Up Addresses
■
If not wall mounted type indoor unit
< Setting Remote Controller Addresses >
1. Press with one end of an unfolded paper clip
(or a similar object that can fit) for 4 seconds or longer.
• The current address number starts blinking.
RC
ADR
Address
1
2
1, 2
Address
< Setting Remote Controller Addresses >
2. Set the address for the remote controller following the procedure under the section
“
■
If not wall mounted type indoor unit” (see this section noted above).
• Repeat Step 2 under “
■
If not wall mounted type indoor unit” if you are setting more units.
• The address setting ready status of the indoor unit ends if data transmission is not received from the remote
controller for 3 minutes.
• Press [Emergency Operation] on the receiver to end the address setting ready status of the indoor unit.
8-10
SM830276-00_欧州向け R32シングル TD&SM.indb 10
19/02/18 11:16:04
Содержание S-50PU2E5B
Страница 12: ... MEMO Xi SM830276 00_欧州向け R32シングル TD SM indb 12 19 02 26 15 26 22 ...
Страница 160: ...1 14 8 MEMO SM830276 00_欧州向け R32シングル TD SM indb 8 2019 02 27 11 55 39 ...
Страница 176: ... MEMO 2 16 SM830276 00_欧州向け R32シングル TD SM indb 16 19 02 28 13 23 00 ...
Страница 182: ... MEMO 3 6 SM830276 00_欧州向け R32シングル TD SM indb 6 19 02 26 10 39 17 ...
Страница 238: ... MEMO 5 38 SM830276 00_欧州向け R32シングル TD SM indb 38 19 02 28 13 29 52 ...
Страница 316: ...201903 SM830276 00_欧州向け R32シングル TD SM indb 1 19 02 15 8 52 12 ...