199
WHEN CONNECTING TO THE COOLING / HEATING SELECTOR
It is possible to secure the cooling, heating and fanning operation connection with the Cooling / Heating Selector.
Follow the procedure for the connection set up below.
1. Connect the wiring (4-wire) to points 1 through 4 on the upper part of the terminal block.
Secure the wiring with the cord clamp located on the right side of the terminal block.
2. Connect the wiring to the Cooling / Heating Selector on the terminal block.
The Cooling / Heating Selector is sold separately as an option.
Model No: CZ-RD1
Refer to the installation manual provided with the Cooling / Heating Selector for further details on the installation.
WHEN CONNECTING TO THE FORCED STOP INPUT
With the Forced Stop input, it is possible to override the air conditioning operation to force a stop if a signal is
received from a fire alarm device, etc.
Connect the wiring (2-wire) to points 5 and 6 on the upper part of the terminal block.
Secure the wiring with the cord clamp located on the right side of the terminal block.
Содержание S-22KA1E5
Страница 4: ...4 23 6 Heating 430 24 Exploded View and Replacement Parts List451 24 1 Indoor Unit 451...
Страница 12: ...12...
Страница 40: ...40 4 1 2 S 56KA1E5 S 63KA1E5 S 71KA1E5...
Страница 41: ...41 4 2 60 x 60 Cassette Type Indoor Unit 4 2 1 S 22YA1E5 S 28YA1E5 S 36YA1E5 S 45YA1E5 S 56YA1E5...
Страница 42: ...42 4 3 95 x 95 Cassette Type Indoor Unit 4 3 1 S 63UA1E5 S 71UA1E5 S 90UA1E5...
Страница 43: ...43 4 4 Slim Hide Away Type Indoor Unit 4 4 1 S 22NA1E5 S 28NA1E5 S 32NA1E5 S 36NA1E5 S 45NA1E5 S 56NA1E5...
Страница 44: ...44 4 5 Low Static Pressure Hide Away Type Indoor Unit 4 5 1 S 45MA1E5 S 56MA1E5...
Страница 45: ...45 4 5 2 S 63MA1E5 S 71MA1E5 S 90MA1E5...
Страница 51: ...51 7 Wiring Connection Diagram 7 1 Wall Mounted Type Indoor Unit KA1E5 Series...
Страница 52: ...52 7 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series...
Страница 53: ...53 7 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series...
Страница 54: ...54 7 4 Slim Hide Away Type Indoor Unit NA1E5 Series...
Страница 55: ...55 7 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series...
Страница 56: ...56 7 6 Outdoor Unit LA1E5 Series...
Страница 57: ...57 8 Electronic Circuit Diagram 8 1 Wall Mounted Type Indoor Unit KA1E5 Series...
Страница 58: ...58...
Страница 59: ...59 8 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series...
Страница 60: ...60...
Страница 61: ...61 8 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series...
Страница 62: ...62...
Страница 63: ...63 8 4 Slim Hide Away Type Indoor Unit NA1E5 Series...
Страница 64: ...64...
Страница 65: ...65 8 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series...
Страница 66: ...66...
Страница 67: ...67 8 6 Outdoor Unit LA1E5 Series...
Страница 68: ...68...
Страница 70: ...70 9 1 3 Receiver PCB CN DISP 9 1 4 Error Code Display PCB CN CODE...
Страница 74: ...74 9 6 Outdoor Unit LA1E5 Series 9 6 1 Main PCB...
Страница 75: ...75 9 6 2 Noise Filter PCB CN TH1 CN OPT4 CN OPT3 CN V1 CN V2 CN OPT1 CN PWR CN OPT2 CN RY1 CN HOT...
Страница 76: ...76 9 6 3 Capacitor PCB DCN IN DCN OUT DCP IN DCP OUT...
Страница 195: ...195...
Страница 201: ...201...