background image

∫ 

Preventing unnecessary recording 

(Voice activated system: VAS)

VAS detects silence and pauses recording automatically.
The voice mark flashes while VAS is waiting for a sound to record.

1 Press and hold [

$

FOLDER /

%

MENU

] while stopped.

2 Within 10 seconds, press [

$

FOLDER /

%

MENU

] until 

“      ”

is displayed.

3 Within 10 seconds, press [

9

] to select 

“On”.

4 Within 10 seconds, press [

1

].

VAS is now on.

To turn the function off:

Press [

:

] to select “OFF” in step 3 and press [

1

].

5

4

1

Press [

$

FOLDER / 

%

MENU] to

select the folder to record into.

2

Press [REC].

Recording begins and the record-
ing indicator lights

.

The meter shows the 
recording level.

3

Press [STOP].

Recording stops.
The display changes in the following order:

Recording time

Total number
of files

File number

∫ 

Recording through the external microphone 
(not included)

Plug the external microphone into the [MIC (PLUG IN POWER)] jack.
Then follow steps 1-3 as illustrated above.

You can use a condenser microphone without a built-in power supply.
Plug type: 3.5 mm (

1

8

in.) monaural

∫ 

Checking available recording time

Press [

$

FOLDER /

%

MENU] while recording.

Press again to restore the display.

When you are not recording, the meter gives you an idea 
of how much memory is left.  It reduces from right to left
as the memory reduces.
When the remaining memory becomes very low, the meter
will flash.

Files can be stored in 4 separate “folders” (A,B,C,D).  Each
folder can hold up to 99 files.
Total recording time depends on the recording mode.

B

M

S

HQ

H

0

  ・  

50

  ・ 

100

  

B

M

S

HQ

H

HQ

B

Note 

.

The recording being made can be lost if the unit receives a
shock (e.g. it is dropped), or if the batteries and cover come
loose.

Leave VAS (below) off when recording important files.

Date

Time Length 

External microphone jack

[MIC (PLUG IN POWER)]

Built-in
microphone

Recording
indicator

This display also appears when the remaining
time becomes very short.  Press [

$

FOLDER /

%

MENU] to show the normal recording 

display.

Recording

∫ 

Changing microphone sensitivity

MIC SENSEMIC SENSE

H

L

MIC SENSEMIC SENSE

H

L

[H] (High): (Factory setting)

Relatively soft sounds are
recorded.

[L] (Low): Only relatively louder

sounds are recorded. 
Use when recording close
to the mouth.

Changing recording mode

Press [REC MODE].

Recording mode changes each time you press the button.

“FULL”

is displayed when there is no time or file numbers left.

Erase unnecessary files to continue recording. (page 7)

B

HQ

M

D

REC

DATE

B

HQ

REC

DATE

PM

B

HQ

HQ

M

S

H

B

B

HQ

0

  ・  

50

  ・ 

100

PM

Meter

HQ

A

Available recording time

(Combined time of all the files)

105 minutes

33 minutes

16 minutes

SP (Standard play)

HQ (High quality)

(factory setting)

LP (Long play)

Recording mode

HQ  

SP  

LP

^_____-- n

Содержание RR-QR120

Страница 1: ... adapts To establish a safe level Start your volume control at a low set ting Slowly increase the sound until you can hear it comfortably and clearly and without distortion Once you have established a comfort able sound level Set the dial and leave it there Care and Use EST 1924 P PC RR US320 0 50 100 REC FOLDER MENU MODE ERASE H REC STOP VOL L MIC SENSE MICROPHONE USB This manual was printed with...

Страница 2: ...for thirty seconds after you remove the batteries or they go flat The settings revert to the factory setting after this time The flash memory preserves files and file information 2 1 HOLD FULL EMPTY FLAT Two AAA R03 LR03 UM 4 not included batteries Replace the batteries when the indicator flashes Inserting the batteries Long life alkaline batteries are recommended If rechargeable batteries are to ...

Страница 3: ... to left as the memory reduces When the remaining memory becomes very low the meter will flash Files can be stored in 4 separate folders A B C D Each folder can hold up to 99 files Total recording time depends on the recording mode B M S HQ H 0 50 100 B M S HQ H HQ B Note The recording being made can be lost if the unit receives a shock e g it is dropped or if the batteries and cover come loose Le...

Страница 4: ... recording 2 Time of recording 3 Length of recording 4 Number of files 3Press 1 Playback starts Play time B HQ M S H Plug in firmly RQT6222 4Adjust the volume Editing FOLDER MENU ERASE Erasing files 1 Press FOLDER MENU to select the folder 2 Press and hold ERASE 3 Within 10 seconds press 9 to select the file The display changes in the following order 4 Within 10 seconds press ERASE The selected fi...

Страница 5: ...ou can Save and edit sound files you have recorded with the unit Convert sound files into text using Dragon NaturallySpeakingR Preferred version 5 0 speech recognition software Only included in For details read the PDF and installation manual for Voice Editor 2 and Dragon NaturallySpeakingR Preferred version 5 0 Connection PC appears when connected and flashes when transferring data Do not disconn...

Страница 6: ... George McVay Drive McAllen TX 78503 In Puerto Rico contact the Panasonic Sales Company Tel 787 750 4300 Fax 787 768 2910 When shipping the unit carefully pack and send it prepaid adequately insured and preferably in the original carton Include a letter detailing the complaint and provide a day time phone number where you can be reached IF REPAIR IS NEEDED DURING THE WARRANTY PERIOD THE PURCHASER ...

Отзывы: