WARNING

To reduce the risk of fire, electric shock or injury to persons, observe the following:

Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the 
manufacturer.

burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and
safety standards such as those published by the National Fire Protection Association (NFPA), and the 
American Society of Heating, Refrigerating and Air-Conditioning Engineers 

(ASHRAE) and the local code

authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means 
to prevent power from being switched on accidentally. When the service disconnecting means cannot be 
locked, securely fasten a prominent warning device, such as a tag, to the service panel.   

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction. 

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel 

Ducted exhaust fans must always be vented to the outdoors.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and 
connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

These models are UL listed for tub and shower enclosures.

If this product is no longer to be used, it must be removed from the ceiling to prevent it from falling.

Do not install with a method which is not approved in the instructions.

This product must be properly grounded.

Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic
distortion which can cause a humming noise in the motor.

Do not disassemble the unit for reconstruction. It may cause fire or electric shock.

The ceiling joist must be able to withstand a static load of at least five times the weight of the product. 

2

GENERAL SAFETY INFORMATION (CONTINUED)

Содержание RG-C811A

Страница 1: ...e risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions WARNING CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury Denotes a hazard that could result in property damage The following symbols are used to classify and describe the t...

Страница 2: ...trical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel Ducted exhaust fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the applica...

Страница 3: ...r ventilation Do not connect multiple units in parallel If two or more units are connected to one switch in parallel the units may not function Do not install the unit where ducts are configured as shown in below Bend close to duct adaptor Squeezed duct Successive bending Excessive bending Adaptor DESCRIPTION These products use a sirocco fan driven by a DC motor powered by an integral transformer ...

Страница 4: ... Blade Grille Junction box Adaptor PCB box Pick A Flow switch Fan body Damper Flex Z Fast bracket Unit inches mm RG C811HA RG C811A UNPACKING DIMENSIONS SUPPLIED ACCESORIES 12 304 10 1 4 260 3 7 8 100 5 7 8 151 7 1 2 190 13 330 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 10 5 8 270 3 3 8 86 7 8 23 5 1 1 2 37 4 1 2 114 13 330 10 1 4 261 3 7 8 100 12 304 10 1 4 260 3 7 8 100 5 ...

Страница 5: ...tion box Neutral White Black Live Fan Ground wire Green DC Motor Fan body Main control circuit Main control circuit Humidity sensor Selector Timer Humidity setting Humidity preset selector Timer preset selector Selector indications on blower unit Factory setting is around 50 Timer preset selector positions 13 330 10 1 4 261 3 7 8 100 Part name Part name No No Blade Grille Junction box Adaptor PCB ...

Страница 6: ...es to protect hands during the installation Remove the tape placed on the damper and adaptor before installation Failure to do so will cause the product to work inefficiently and create a loud noise OPERATION RG C811HA only INSTALLATION RETROFIT FEATURES Power switch Conden sation sensor Product ON OFF Stop Run Environment humidity Humidity trigger setting about 5 RH Delay 1 operation The product ...

Страница 7: ...apping screws Flex Z Fast bracket position can be adjusted from 16 to 24 406mm to 610mm between joists Install Flex Z Fast bracket Joist 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 2 Joist Flex Z Fast bracket Joist Align the edge of Flex Z Fast with the edge of the ceiling opening on the side where the adapter will be installed Drywall Flex Z Fast bracket 1 Joist Drywall Joist INSTALLATION...

Страница 8: ...he screw does not strip or come in contact with Flex Z Fast bracket 2 3 Insert circular exhaust duct 1 2 4 Remove screw from junction box cover to remove the knock out hole and secure conduit or stress relief to junction box knock out hole Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape A 4 inch circular duct is needed to connect to...

Страница 9: ...ring the installation Remove the tape placed on the damper and adaptor before installation Failure to do so will cause the product to work inefficiently and create a loud noise 1 Install Flex Z Fast bracket Flex Z Fast bracket position can be adjusted from 16 to 24 406mm to 610mm between joists Unit inches mm Joist Bend down 4 tabs 1 2 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 1 2 Align ...

Страница 10: ...r over 140 F 60 C Do not use cleaning sprays solvents or water on or near the sensor 10 Follow steps from RETROFIT Installation 1 Follow the steps 4 to 7 on INSTALLATION RETROFIT Remove grille 1 Gloves Slot Grille Mounting spring 1 Remove grille by pulling down one mounting spring then pull the other Extend Joist 3 4 2 Tapping screws ST4 2X20 3 4 Extend bracket to the other joist Install bracket t...

Страница 11: ...ps alignment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Insulation Foil tape tightly covers all metal duct joints glue PVC joints Model No Air direction Voltage V Frequency Hz Duct diameter inches Air volume at 0 1 WG CFM Noise sones Speed rpm Power W Weight lb k Exhaust Exhaust 80 80 110 110 0 5 0 5 0 3 0 3 824 984 824 984 6 5 11 1 6 5 11 1 9 3 4 2 9 5 4 3...

Страница 12: ... how long an implied warranty lasts so the above exclusions or limitation may not apply to you Obtain Product Information and Operating Assistance locate your nearest distributor or make Customer Service and Literature requests by visiting our Web Site at us panasonic com ventfans or send your request by E mail to ventfans us panasonic com You may also contact us directly at 1 866 292 7299 Monday ...

Отзывы: