Properly insulate the area around the fan to minimize 
building heat loss and gain. Loose fill or batt 
insulation can be placed directly over the fan housing 
in the attic. Our fans do not create excessive heat 
that is a common problem with recessed light fixtures 
or some competitor’s fan/light combination. Our 
efficient, cool-running motors do not create enough 
ambient heat to be subjected to these limitations. 
The ducting from this fan to the outside of the building 
has a strong effect on the air flow, noise and energy 
use of the fan. Use the shortest, straightest duct routing 
possible for best performance, and avoid installing the 
fan with smaller ducts than recommended. Insulation 
around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve 
their rated air flow.

4 inches roof jack, wall cap,
or soffit vent with backdraft damper

Mechanically connect duct to termination
and seal with mastic or approved foil 
faced tape

2-3 ft straight run before elbow

In attic installation, 
caulk box to drywall 

Short piece of flexible duct helps
alignment and absorbs sound. 
Clamps plus mastic or approved
foil faced tape at all flex joints

Insulation

Foil tape tightly covers all metal
duct joints (glue PVC joints)

Model No. 

Air

direction

Voltage

(V)

Frequency

(Hz)

Duct

diameter

(inches)

Air volume

at 0.1” WG

(CFM)

Noise

(sones)

Speed

(rpm)

Power

(W)

Weight
lb. (k  )

Exhaust

Exhaust

80

80

110

110

0.5

0.5

<0.3

<0.3

824

984

824

984

6.5

11.1

6.5

11.1

9.3(4.2)

9.5(4.3)

120

120

60

60

4 or 6 

4 or 6 

HVI Certified performance based on HVI Procedures 915, 916, 920.

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. 
Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit
require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA).

RG-C811A

RG-C811HA

11

2

3

Remove dust and dirt from fan body 
using a vacuum cleaner.

Using a cloth dampened with kitchen detergent, 
remove any dirt from fan body. Wipe dry with clean 
cloth. Reinstall grille after finishing.

2

3

Maintenance of unit

Gloves

1

1

Clean grille. (Don’t put into hot water. Use non-abrasive
kitchen detergent, wipe dry with clean cloth.)

NOTE: The grille should be dry after cleaning. 

MAINTENANCE (CLEANING) (CONTINUED)

SPECIFICATIONS

PRODUCT SERVICE

Drywall

Drywall

PRACTICAL GUIDE TO INSTALLATION

Vacuum
cleaner

Gloves

Содержание RG-C811A

Страница 1: ...e risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions WARNING CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury Denotes a hazard that could result in property damage The following symbols are used to classify and describe the t...

Страница 2: ...trical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel Ducted exhaust fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the applica...

Страница 3: ...r ventilation Do not connect multiple units in parallel If two or more units are connected to one switch in parallel the units may not function Do not install the unit where ducts are configured as shown in below Bend close to duct adaptor Squeezed duct Successive bending Excessive bending Adaptor DESCRIPTION These products use a sirocco fan driven by a DC motor powered by an integral transformer ...

Страница 4: ... Blade Grille Junction box Adaptor PCB box Pick A Flow switch Fan body Damper Flex Z Fast bracket Unit inches mm RG C811HA RG C811A UNPACKING DIMENSIONS SUPPLIED ACCESORIES 12 304 10 1 4 260 3 7 8 100 5 7 8 151 7 1 2 190 13 330 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 10 5 8 270 3 3 8 86 7 8 23 5 1 1 2 37 4 1 2 114 13 330 10 1 4 261 3 7 8 100 12 304 10 1 4 260 3 7 8 100 5 ...

Страница 5: ...tion box Neutral White Black Live Fan Ground wire Green DC Motor Fan body Main control circuit Main control circuit Humidity sensor Selector Timer Humidity setting Humidity preset selector Timer preset selector Selector indications on blower unit Factory setting is around 50 Timer preset selector positions 13 330 10 1 4 261 3 7 8 100 Part name Part name No No Blade Grille Junction box Adaptor PCB ...

Страница 6: ...es to protect hands during the installation Remove the tape placed on the damper and adaptor before installation Failure to do so will cause the product to work inefficiently and create a loud noise OPERATION RG C811HA only INSTALLATION RETROFIT FEATURES Power switch Conden sation sensor Product ON OFF Stop Run Environment humidity Humidity trigger setting about 5 RH Delay 1 operation The product ...

Страница 7: ...apping screws Flex Z Fast bracket position can be adjusted from 16 to 24 406mm to 610mm between joists Install Flex Z Fast bracket Joist 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 2 Joist Flex Z Fast bracket Joist Align the edge of Flex Z Fast with the edge of the ceiling opening on the side where the adapter will be installed Drywall Flex Z Fast bracket 1 Joist Drywall Joist INSTALLATION...

Страница 8: ...he screw does not strip or come in contact with Flex Z Fast bracket 2 3 Insert circular exhaust duct 1 2 4 Remove screw from junction box cover to remove the knock out hole and secure conduit or stress relief to junction box knock out hole Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape A 4 inch circular duct is needed to connect to...

Страница 9: ...ring the installation Remove the tape placed on the damper and adaptor before installation Failure to do so will cause the product to work inefficiently and create a loud noise 1 Install Flex Z Fast bracket Flex Z Fast bracket position can be adjusted from 16 to 24 406mm to 610mm between joists Unit inches mm Joist Bend down 4 tabs 1 2 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 1 2 Align ...

Страница 10: ...r over 140 F 60 C Do not use cleaning sprays solvents or water on or near the sensor 10 Follow steps from RETROFIT Installation 1 Follow the steps 4 to 7 on INSTALLATION RETROFIT Remove grille 1 Gloves Slot Grille Mounting spring 1 Remove grille by pulling down one mounting spring then pull the other Extend Joist 3 4 2 Tapping screws ST4 2X20 3 4 Extend bracket to the other joist Install bracket t...

Страница 11: ...ps alignment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Insulation Foil tape tightly covers all metal duct joints glue PVC joints Model No Air direction Voltage V Frequency Hz Duct diameter inches Air volume at 0 1 WG CFM Noise sones Speed rpm Power W Weight lb k Exhaust Exhaust 80 80 110 110 0 5 0 5 0 3 0 3 824 984 824 984 6 5 11 1 6 5 11 1 9 3 4 2 9 5 4 3...

Страница 12: ... how long an implied warranty lasts so the above exclusions or limitation may not apply to you Obtain Product Information and Operating Assistance locate your nearest distributor or make Customer Service and Literature requests by visiting our Web Site at us panasonic com ventfans or send your request by E mail to ventfans us panasonic com You may also contact us directly at 1 866 292 7299 Monday ...

Отзывы: