Chapter 4
Settings — [DISPLAY OPTION] menu
104 - ENGLISH
3) Press the <ENTER> button.
f
The
[MEASURED MODE]
screen is displayed.
4) Press
as
to select [MEASURED DATA].
5) Press the <ENTER> button.
f
The
[MEASURED DATA]
screen is displayed.
6)
Measure the current luminance (Y) and the chromaticity coordinates (x, y) using the colorimeter.
7) Press
as
to select a color, and press
qw
to adjust the setting.
f
Set [AUTO TESTPATTERN] to [ON] to display a test pattern of selected colors.
8)
Once all the input is completed, press the <MENU> button.
f
The
[MEASURED MODE]
screen is displayed.
9) Press
as
to select [TARGET DATA].
10) Press the <ENTER> button.
f
The
[TARGET DATA]
screen is displayed.
11) Press
as
to select a color and press
qw
to input coordinates for desired colors.
f
By setting [AUTO TESTPATTERN] to [ON], the test pattern for the selected color is displayed.
12)
Once all the input is completed, press the <MENU> button.
Note
f
Colors are not displayed properly when target data is a color outside the region of this projector.
f
Set the [AUTO TESTPATTERN] to [ON] to automatically display a test pattern for use in adjusting the selected adjustment colors.
f
The [AUTO TESTPATTERN] setting will change in conjunction with the setting in the [ADVANCED MENU] menu
→
[EDGE BLENDING]
→
[ON]/[USER]
→
[AUTO TESTPATTERN].
f
When using a colorimeter or similar instrument to take measurement, measure the colors displayed in [AUTO TESTPATTERN].
f
It is recommended to enter the value between [1000] and [32768] in [Y(RELATIVE)] of [WHITE] in the
[MEASURED DATA]
screen. For
each value ([Y(RELATIVE)] of [BLACK], [RED], [GREEN], and [BLUE]), enter the relative value for the [Y(RELATIVE)] value of [WHITE]
based on the luminance (Y) of each color measured using the colorimeter.
f
A difference in the color coordinates of target data and measurement value obtained from an instrument may occur for certain instrument
and measurement environment used.
[COLOR CORRECTION]
Colors can be adjusted and registered for each input signal format.
1) Press
as
to select [COLOR CORRECTION].
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Standard setting.
[USER]
For each signal format of RGB signal and YC
B
C
R
/YP
B
P
R
signal, six colors of red, green, blue, cyan,
magenta, and yellow can be adjusted and registered. Press the <ENTER> button and set the details.
Adjustment is possible within the range of -31 to +31.
[SCREEN SETTING]
Set the screen size.
Correct to the optimum image position for the set screen when the aspect ratio of a projected image is changed.
Set as necessary for the screen in use.
1) Press
as
to select [SCREEN SETTING].
2) Press the <ENTER> button.
f
The
[SCREEN SETTING]
screen is displayed.
3) Press
qw
to switch the [SCREEN FORMAT] item.
f
The items will switch each time you press the button.
Содержание PT-RZ120BEJ
Страница 55: ...ENGLISH 55 Chapter 3 Basic Operations This chapter describes basic operations to start with...
Страница 158: ...158 ENGLISH Chapter 5 Operations This chapter describes how to use each function...
Страница 188: ...188 ENGLISH Chapter 7 Appendix This chapter describes specifications and after sales service for the projector...