ADJ-9
SECTION 3 ADJUSTMENTS
1. 5. 4. Restore the data (after board replacing)
1. Set the projector to "Normal-Standby" mode (POWER indicator is Lighting in red).
2. Start up the software "ServiceEZ770.exe" with a PC.
3. Select language and click the [OK] button.
4. 1) Choose the available serial port number on your PC.
2) Choose a model number.
3) Click the [Data] button.
5. 1) Click the [Transmission] button of Gamma Data.
2) Select the save place and click the [ Open(O) ] button.
3) When the progress bar reaches the right-side end, the transmission of data is completion.
4) Restore the Uniformity correction data in the same procedure of 1-3.
6. After completing the writing, turn the main power off and on, and check the color uniformity and gamma characteristic of
the projector.
k