INF-30
SECTION 1 SERVICE INFORMATION
6. 2. 4. Error cord of system log
Bit
Error code (hex)
Factor
Description
0
LOWER
00000000 00000001 Intake air temperature warning
Internal temperature rising warning/ Error
• The ventilation holds are blocked
• Environment temperature is high
• Air filter clogged
1
00000000 00000002 Not used
2
00000000 00000004 Exhaust air temperature warning
3
00000000 00000008 Not used
4
00000000 00000010 Intake air temperature error
5
00000000 00000020 Not used
6
00000000 00000040 Exhaust air temperature error
7
00000000 00000080 Not used
8
00000000 00000100 Lamp runtime warning
The lamp runtime reaches 2 800 hours
9
00000000 00000200 Not used
10
00000000 00000400 Not used
11
00000000 00000800 Not used
12
00000000 00001000 Lamp runtime has elapsed
The lamp runtime reaches 3 000 hours
13
00000000 00002000 Not used
14
00000000 00004000 Not used
15
00000000 00008000 Not used
16
00000000 00010000 Lamp failure
Lamp failure
17
00000000 00020000 Not used
18
00000000 00040000 Not used
19
00000000 00080000 Not used
20
00000000 00100000 Lamp ignition error
Lamp ignition error
- There is a possibility that has restarted in hot state.
21
00000000 00200000 Not used
22
00000000 00400000 Not used
23
00000000 00800000 Not used
24
00000000 01000000 No lamp installed
Lamp is not installed (can not read out the data from
lamp memory)
Wrong type lamp is installed
25
00000000 02000000 Not used
26
00000000 04000000 Not used
27
00000000 08000000 Not used
28
00000000 10000000 Not used
29
00000000 20000000 Lamp cover not installed securely
Lamp cover is not installed securely
30
00000000 40000000 Not used
31
00000000 80000000 Not used
32
0000000100000000 Intake air temperature sensor disconnected
Intake air temperature sensor disconnected
33
00000002 00000000 Not used
34
00000004 00000000 Exhaust air temperature sensor disconnected Exhaust air temperature sensor disconnected
35
00000008 00000000 Air filter clogged sensor disconnected
Air filter clogged sensor disconnected
36
00000010 00000000 Air filter clogged warning
Air filter may accumulate dust
37
00000020 00000000 Battery replacement for the internal clock
Remaining battery level is low
38
00000040 00000000 Angle sensor error
Angle sensor failure
39
00000080 00000000 Not used
40
00000100 00000000 Air filter not installed
Air filter not installed
41
00000200 00000000 Not used
42
00000400 00000000
FAN1(LCD R) error/warning
Fan or fan drive circuit has failure.
Fan replacement time
43
00000800 00000000
FAN2(LCD G) error/warning
44
00001000 00000000
FAN3(LCD B) error/warning
45
00002000 00000000
FAN4(PBS) error/warning
46
00004000 00000000
FAN5(LAMP1) error/warning
47
00008000 00000000
FAN6(LAMP2) error/warning
48
00010000 00000000
FAN7(POWER) error/warning
49
00020000 00000000
FAN8(EXHST) error/warning
50
00040000 00000000 Not used
51
00080000 00000000 Not used
52
00100000 00000000 Not used
53
00200000 00000000 Not used
54
00400000 00000000 Not used
55
00800000 00000000 Not used
56
01000000 00000000 Not used
57
02000000 00000000 Not used
58
04000000 00000000 Not used
59
08000000 00000000 Not used
60
10000000 00000000 Not used
61
20000000 00000000 Not used
62
40000000 00000000 Not used
63
80000000 00000000 Not used