PROJECTOR SETUP menu
ENGLISH -
81
Settings
Details of error
z
Error message
Remedial measure
[Exceed maximum
number of projectors.]
Limit number of
•
projectors in same group
to 8.
When linking 9 or
•
more projectors, use a
computer and the [Multi
Projector Monitoring &
Control Software].
[Please check the
COMMAND CONTROL
setting.]
Turn [ON] the
•
[COMMAND CONTROL]
on the on-screen menu
[NETWORK CONTROL]
for the projector with the
error display.
Set [COMMAND
•
PORT] of [NETWORK
CONTROL] of all linked
projectors to the same
value.
[Please check the
USER NAME and
PASSWORD in the
COMMAND CONTROL
setting.]
Set the [USER NAME]
•
and [PASSWORD] for the
administrator authority for
[WEB CONTROL] of all
the linked projectors to
the same text string.
[Cannot apply
BRIGHTNESS
CONTROL. Please
check projector status.]
Projector is in standby
•
state. Turn on power.
[Brightness Sensor
Error]
There is a fault in the
•
brightness sensor. If the
fault is not corrected by
turning the power off and
back on, consult your
dealer.
Note
If the linked projectors are not listed, check the following.
z
The devices on the network all have different IP
•
addresses.
The LAN cable is connected correctly.
•
The sub-nets of the projectors are the same.
•
The [LINKS] are set in the same group.
•
For changing the projector name, refer to
z
When [MODE] of brightness control is
Q
set to [PC]
The name of this projector is displayed.
The state is indicated by color.
GREEN : The brightness can be corrected by a
significant margin.
YELLOW : The brightness can no longer be
corrected by a significant margin.
RED : There is an error in brightness control.
Example of adjustment procedure
J
for brightness control
The following is an example of adjustment procedure
for linking the brightness of 8 projectors that form a
network.
Connect all the projectors to the hub
1 )
using the LAN cables. (
Turn on the power in all projectors.
2 )
Ensure [LAMP SELECT] of all the
3 )
projectors are either all set to [DUAL]
or all set to [SINGLE].
Set [MODE] of [BRIGHTNESS
4 )
CONTROL SETUP] to [OFF], and
select [APPLY].
Set [SUBNET MASK] of all the
5 )
projectors to the same value and set
their [IP ADDRESS] to different values
so that network communication can
be performed.
Wait at least 8 minutes until the lamp
6 )
power stabilizes.
Set all the items in the [PICTURE]
7 )
menu of all the projectors to the same
value.
To match the color, adjust [COLOR
8 )
MATCHING].
RETURN
MENU
MODE
PC
PROJECTOR2
BRIGHTNESS CONTROL STATUS
Содержание PT-DS100XE ( )