33
ENGLISH
• Insert the input module that meets the input signal specifications.
• Use the SYSTEM SELECTOR button to select the input module that meets desired one of the eight types
(14 formats) of signal specifications (SMPTE292M).
While toggling through those eight types, input signal and other information are displayed and cleared on the
screen automatically.
• Normally, use SYSTEM SELECTOR in “AUTO”.
• Automatic detection may malfunction if connection is made in any other way than listed above or if any unstable signal is
connected. If this happens, switch to a system that is compatible with the signal format using the SYSTEM SELECTOR button.
• Use a 5CFB or superior cable for connection to transmit the image information without error.
(Example: 5CFB, 5CFTX, 7CFB etc.)
IN
OUT
1080i/720p Module
ET-MD95SD3
HD SERIAL
HD SD signal
HD SD signal output
(active through)
Serial digital input module (optional)
ET-MD95SD3 (for HD SDI)
Business-use
digital video deck
1080/25p
1080/30p
1080/50i
1080/24p
1080/24sF
1080/60i
AUTO
1035/60i
720/60p
DVI-D IN
DVI-D OUT
DVI Module
ET-MD75DV
DVI-D input module (optional)
ET-MD75DV
DVI signal
PC with DVI output
Connecting signals to the DVI signal input module
• Pin assignments and signal names of DIV-D input
terminal are listed in the table at right (terminal for
TMDS-equipped PC).
Pin No.
Pin No.
Signal
TMDS data 2—
TMDS data 2+
TMDS data 2 / 4
shield
T.M.D.S data 4—
T.M.D.S data 4+
DDC clock
DDC data
T.M.D.S data 1—
T.M.D.S data 1+
T.M.D.S data 1/3
shield
T.M.D.S data 3—
Signal
T.M.D.S data 3+
+5V
Ground
Hot plug detection
T.M.D.S data 0—
T.M.D.S data 0+
T.M.D.S data 0/5
shield
T.M.D.S data 5—
T.M.D.S data 5+
T.M.D.S clock
shield
T.M.D.S clock+
T.M.D.S clock—
External view