J
STATUS
Q
Projector status
Click the
Projector status
tab on the top.
Error information
When
Error (Detail)
is displayed in
SELF TEST
in the
status list, click
(Detail)
to display the error details.
PROJECTOR TYPE
Displays the type of projector.
MAIN VERSION
Displays the firmware version of the
projector main unit.
INPUT
Displays the input switching status.
INPUT AIR
TEMPERATURE
Displays temperature of projector’s
intake air.
OPTICS MODULE
TEMPERATURE
Displays temperature inside the
projector.
AROUND LAMP
TEMPERATURE
Displays temperature around lamp
units.
LAMP1 RUNTIME
/
LAMP2
RUNTIME
Displays the lamp lit hours.
PROJECTOR RUNTIME
Displays used hours of the projector.
SELF TEST
Displays self diagnosis information.
Click
(Detail)
Parameter
Description
MAIN CPU BUS
Trouble has occurred in the
microcomputer circuitry. Consult your
dealer.
FAN
Trouble has occurred in the fan or its
drive circuit. Consult your dealer.
INPUT AIR
TEMPERATURE
The input air temperature is too high. It
may be that the projector is being used
in an operating environment where the
temperature is high such as near a
heating appliance.
OPTICS MODULE
TEMPERATURE
The temperature inside the projector is
high. It may be that the projector is
being used in an operating
environment where the temperature is
high such as near a heating appliance.
AROUND LAMP
TEMPERATURE
The temperature around the lamp is
too high. It may be that the projector’s
ventilation holes are blocked.
LAMP1 REMAIN TIME
The lamp runtime has exceeded the
prescribed cumulative time, and it is
now time to replace the lamp.
LAMP2 REMAIN TIME
LAMP1 STATUS
The lamp has failed to light. Wait a
short while for the lamp to cool off, and
then turn on the power.
LAMP2 STATUS
SHUTTER
Trouble has occurred in the shutter
circuitry. Consult your dealer.
INPUT AIR TEMP.SENSOR
Trouble has occurred in the sensor
used to detect the input air
temperature. Consult your dealer.
OPTICS MODULE
TEMP.SENSOR
Trouble has occurred in the
temperature detection sensor inside
the projector. Consult your dealer.
AROUND LAMP
TEMP.SENSOR
Trouble has occurred in the sensor
used to detect the exhaust air
temperature. Consult your dealer.
BATTERY
The backup battery has been run out.
Consult your dealer.
AIRFLOW SENSOR
Trouble has occurred in the sensor
used to detect the airflow volume.
Consult your dealer.
COLOR WHEEL
Trouble has occured in the colour
wheel or colour wheel or its drive
circuit. Consult your dealer.
COVER OPEN
The lamp unit cover is not attached
securely. Check the lamp unit
compartment.
ACF UNIT
The air cleaning filter (ACF) is not
installed or trouble has occurred. See
the operating instructions booklet that
is provided with the projector.
FILTER REMAIN
The filter remaining is getting less. See
the operating instructions booklet that
is provided with the projector.