- 2 -
Service Manual
Important Safety Notice
Special components are used in this projection television that are important for safety. These components are
identified on the schematic diagram by the symbol
and printed in BOLD TYPE on the replacement part list. It is
essential that these critical parts be replaced with the manufacturer’s specified replacement part to prevent x-ray
radiation, shock, fire or other hazards. Do not modify the original design without the manufacturer’s permission.
Safety Precautions
General Guidelines
An
isolation transformer
should always be used
during the servicing of a PTV whose chassis is not
isolated from AC power line. Use a transformer of
adequate power rating as this protects the technician
from accidents resulting in personal injury from
electrical shocks. It will also protect the PTV from being
damaged by accidental shorting that may occur
during servicing.
When servicing, observe the original lead dress,
especially in the high voltage circuit. Replace all
damaged parts (also parts that show signs of
overheating.)
Always replace protective devices, such as
fishpaper, isolation resistors and capacitors, and
shields after servicing the PTV. Use only
manufacturer’s recommended rating for fuses, circuits’
breakers, etc.
High potentials, as high as 32kV, are present when this
PTV is operating. Operation of the PTV without the rear
cover introduces danger for electrical shock. Servicing
should not be performed by anyone who is not
thoroughly familiar with the necessary precautions
when servicing high-voltage equipment.
Extreme care should be practiced when handling the
picture tube
. Rough handling may cause it to implode
due to atmospheric pressure. (14.7 lbs. per sq. in.). Do
not nick or scratch the glass or subject it to any undue
pressure. When handling, use safety goggles and
heavy gloves for protection. Discharge the picture
tube by shorting the anode to chassis ground (not to
the cabinet or to other mounting hardware). When
discharging, connect cold ground (i.e. DAG ground
lead) to the anode with a well-insulated wire or use a
grounding probe.
X-ray Precautions
The front area (between the projection tube and the
lens) is enclosed by a metal box to ensure positive
safety during normal and abnormal conditions when
checking and repairing. To fully ensure safety, the
following precautions must be observed.
1.
Do not remove the lens or metal box.
2.
Make sure to turn the power OFF when the lens is
removed or when checking the cleanliness of the
lens.
3.
Do not remove the lens or metal box to check the
projection tube for operation by watching it directly.
Use a mirror or paper to view the image.
Before returning a serviced PTV to the owner, the
service technician must thoroughly test the unit to
ensure that is completely safe to operate. Do not use a
line isolation transformer when testing.
Leakage Current Cold Check
Unplug the AC cord and connect a jumper between the
two plug prongs. Press the POWER switch ON.
Measure the resistance between the jumpered AC plug
and expose metallic parts such as screw heads,
antenna terminals, control shafts, etc. If the exposed
metallic part has a return path to the chassis, the
reading should be between 240kW and 5.2MW. If the
exposed metallic part does not have a return path to
the chassis, the reading should be infinite.
Leakage Current Hot Check
(See Fig. 1)
Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer during the check.
Connect a 1.5kW 10-watt resistor in parallel with a
0.15mF capacitor between and exposed metallic part
and ground. Use earth ground, for example a water
pipe.
Using a DVM with a 1000 ohms/volt sensitivity or
higher, measure the AC potential across the resistor.
Repeat the procedure and measure the voltage
present with all other expose metallic parts.
Verify any potential does not exceed 0.75 volt RMS. A
leakage current tester (such a Simpson Model 229,
Sencore Model PR57 or equivalent) may be used in
the above procedure, in which case any current
measure must not exceed 0.5 milliamp. If any
measurement is out of the specified limits, there is a
possibility of a shock hazard and the PTV must be
repaired and rechecked before it is returned to the
customer.
Insulation Test
Connect an insulation tester between an exposed
metallic part and AC line.
Apply 1080VAC/60Hz for 1 second. Confirm that the
current measurement is 0.5mA ~ 2.0mA. Repeat test
with other metallic exposed parts.
X-ray Radiation
WARNING: The potential source of X-ray radiation in the
PTV is in the high voltage section and the picture tube.
Note: It is important to use calibrated equipment.
Apply all black video signals (1080i) and confirm high
voltage measures 31.5 ± 1.0kV. If the high voltage is
not within the range, change C514 to 1800pF, 2000pF,
2400pF or 2700pF until the desired value is obtained.
Apply NTSC Lion Head Pattern and confirm the high
voltage measures 30.1 ± 1.5kV.
Apply HD 1081I Monoscope Pattern and confirm the
high voltage measures 30.1 ± 1.5kV
Figure 1. Hot Check Circuit
Содержание PT- 65WX51E
Страница 25: ... 25 Service Manual G Board K Board Schematics G Board Schematic K Board Schematic ...
Страница 26: ... 26 Service Manual G Board K Board PCB G Board PCB K Board PCB ...
Страница 27: ... 27 Notes ...
Страница 28: ... 28 Printed in USA K01062205PL0627 ...
Страница 56: ... 28 A BOARD SCHEMATIC DIAGRAMA ELÉCTRICO TARJETA A A BOARD TARJETA A ...
Страница 57: ... 29 A BOARD SCHEMATIC DIAGRAMA ELÉCTRICO TARJETA A A BOARD TARJETA A ...
Страница 58: ... 30 A BOARD SCHEMATIC DIAGRAMA ELÉCTRICO TARJETA A A BOARD TARJETA A ...
Страница 59: ... 31 A BOARD SCHEMATIC DIAGRAMA ELÉCTRICO TARJETA A A BOARD TARJETA A ...
Страница 61: ... 33 Notes ...
Страница 62: ... 34 Printed in USA K01052203ZR0511 ...
Страница 111: ... 49 ALL MODELS D Board Layout ...
Страница 112: ... 50 ALL MODELS D Board Schematic Left Portion ...
Страница 113: ... 51 ALL MODELS D Board Schematic Right Portion ...
Страница 114: ... 52 ALL MODELS A Board Schematic Left Portion ...
Страница 115: ... 53 ALL MODELS A Board Schematic Left Middle Portion ...
Страница 116: ... 54 ALL MODELS A Board Schematic Right Middle Portion ...
Страница 117: ... 55 ALL MODELS A Board Schematic Right Portion ...
Страница 118: ... 56 ALL MODELS DH Board Schematic ...
Страница 125: ... 63 Notes ...