FP-X series
Input specifications (control unit, expansion unit and add-on cassette)
Relay output specifications (control units, expansion units)
Note:
*2
Please refer to the user manual for Y0 to Y7 of the transistor output type.
Item
Description
Insulation method
Output type
Rated load voltage
Load voltage allowable range
Max. load current
Max. inrush current
Output points per common
OFF state leakage current
ON state voltage drop
Response time
Voltage range for external power supply
Surge absorber
Operating indicator
Photocoupler
Open collector
1.5A
1
M
A or less
Zener diode
LED display
Add-on cassette (AFPX-TR8, AFPX-TR6P, AFPX-IN4T3)
Control unit, Expansion unit
NPN type: 5 to 24VDC, PNP type: 24VDC
NPN type: 4.75 to 26.4VDC, PNP type: 21.6 to 26.4VDC
0.5A
24VDC
21.6 to 26.4VDC
NPN type: 0.3A, PNP type: 0.5A
TR8: 8 points/common, TR6P: 6 points/common, IN4T3: 3 points/common
1.5VDC or less
0.1ms or less
0.8ms or less
—
0.3VDC or less
1ms or less*
2
1ms or less*
2
21.6 to 26.4VDC
C14: 6 points/common, E16: 8 points/common, C30, C60, E30: 8 or 6 points/common
OFF
m
ON
OFF
m
ON
Transistor output specifications (Control unit, expansion unit and add-on cassette)
Specifications
Item
Description
Insulation method
Rated input voltage
Operating voltage range
Rated input current
Input points per common
Min. ON voltage/ON current
Max. OFF voltage/OFF current
Input impedance
Response
time
Operating indicator
Photocoupler
24VDC
21.6 to 26.4VDC
(Input power polarity either positive or negative)
Same as above
LED display
Note:
*1
Specification at the rated input voltage of 24VDC, 25°C.
Control unit X0 to X7
0.6ms or less: Normal input
50
M
s or less: High-speed counter, pulse catch,
interruption input setting *
1
Control unit X8 and after, Expansion unit
0.6ms or less
Control unit X0 to X3
135
M
s or less: Nominal input
5
M
s or less: High-speed counter, pulse catch,
interruption input setting*
1
Control unit X4 to X7
135
M
s or less: Nominal input
50
M
s or less: High-speed counter, pulse catch,
interruption input setting*
1
Control unit X8 and after, Expansion unit
0.6ms or less
19.2V/3 mA
2.4V/1 mA
Approx. 5.1k
7
(Control unit X0 to X7)
Approx. 5.6k
7
(Control unit X8 and after, Expansion unit)
19.2V/6mA (Control unit X0 to X3)
19.2V/3mA (Control unit X4 and after, Expansion unit)
2.4V/1.3mA (Control unit X0 to X3)
2.4V/1mA (Control unit X4 and after, Expansion unit)
Approx. 3k
7
(Control unit X0 to X3)
Approx. 5.1k
7
(Control unit X4 to X7)
Approx. 5.6k
7
(Control unit X8 and after, Expansion unit)
Approx. 4.7mA (Control unit X0 to X7)
Approx 4.3mA (Control unit X8 and after, Expansion unit)
Approx. 8mA (Control unit X0 to X3)
Approx. 4.7mA (Control unit X4 to X7)
Approx. 4.3mA (Control unit X8 and after, Expansion unit)
Approx. 3.5mA
1.0ms or less
1.0ms or less
8 points/common (C14, E16) 16 points/common (C30, C60, E30)
8 points/common (AFPX-IN8), 4 points/common (AFPX-IN4T3)
19.2V/3mA
2.4V/1mA
Approx. 6.8k
7
Relay output (control unit and expansion unit)
Transistor output (control unit and expansion unit)
Add-on cassette (AFPX-IN8, AFPX-IN4T3)
OFF
m
ON
OFF
m
ON
Item
Description
Output type
Rated control capacity (Resistive load)
Output points per common
Response time
Life time
Surge absorber
Operating indicator
1a contact
2A 250VAC, 2A 30VDC (8A or less/common)
C14, E16: 1 point or 3 points/common, C30, E30: 1 point or 4 points/common, C60: 1, 2 or 4 points/common
Approx. 10ms
Approx. 8ms
20 million operations or more (Operation frequency 180 times/min)
100,000 operations or more (Operation frequency 20 times/min at the rated control capacity)
None
LED display
Mechanical
Electrical
OFF
m
ON
ON
m
OFF
01/2008