71
PAW-VP•LDHW - Technical Manual – 2020-07
Electrical Wiring
7
7.4.3 How to mount the E1, E2 and E3 sensors on the pipes
Maximum contact
Most sensitive point of the thermistor
Cover the thermistor and the pipe with
aluminum tape, then the aluminum
tape with thermal insulation.
Installation of temperature sensors
To prevent condensation entering the termi
-
nals on the electrical lines, the following must
be observed. Install them with a downwards
running U-shaped loop.
Hold the temperature sensor so that the
measuring tip points upwards. Let the control
cable of the temperature sensor hang loosely,
insert the tip of the temperature sensor to the
pipeline.
To ensure heat transfer please use heat con
-
ducting paste (not included in delivery)
Wrap aluminum tape (field supplied) around
the probe tip and pipe to attach the tempera
-
ture sensor, then cover with thermal insulation
and secure to pipe as shown.