CHARACTERISTICS

WIRING DIAGRAMS

PM4H-A

Type

Item

PM4H-S

100 to 240V AC, 12V DC, 24V AC/DC, 48 to 125V DC

Rated operating voltage

50/60Hz common (AC operating type)

5A 250V AC (resistive load)

Power ON-delay

Pulse ON-delay
Pulse Flicker
Pulse ON-Flicker
Differential ON/OFF-delay (1) (2)
Signal OFF-delay
Pulse One-shot
Pulse One-cycle

Power ON-delay
Power Flicker
Power ON-flicker
Power One-shot
Power One-cycle
(with instantaneous contact)

Rated frequency

Output rating

1s to 500h (Max.) 16 time ranges switchable

±

0.3% (power off time change at the range of 0.1s to 1h)

±

5% (Full-scale value)

±

0.5% (at the operating voltage changes between 85 to 110%)

Max. 100m

 (at 1A 6V DC)

±

2% (at 20

°

C ambient temp. at the range of –10 to +50

°

+14 to +122

°

F

)

Timed-out 1 Form C

Instantaneous 1 Form C

Time range
Operating time fluctuation

2

×

10

7

10

5

 (at rated control capacity)

Mechanical (contact)
Electrical (contact)

85 to 110% of rated operating voltage (at 20

°

C coil temp.)

Allowable operating voltage range

–10 to +50

°

+14 to +122

°

F

Ambient temperature

Max. 85%RH

Ambient humidity

860 to 1,060hPa

Atmospheric pressure

20%

Ripple factor (DC type)

IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>

Protective construction

100g 

3.527 oz

 (Pin type)

110g 

3.880 oz

 (Screw terminal type)

Weight

Min. 98m/s

2

 (4 times on 3 axes)

Shock resistance

Min. 980m/s

2

 (5 times on 3 axes)

10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes)

Vibration resistance

10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes)

Functional
Destructive
Functional
Destructive

Between live and dead metal parts
Between input and output
Between contacts of different poles
Between contacts of same pole

Insulation resistance (Initial value)

2,000Vrms for 1 min Between live and dead metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles
1,000Vrms for 1 min Between contacts of same pole

Breakdown voltage (Initial value)

Setting error
Voltage error

Contact resistance (Initial value)

100ms

Min. power off time

55

°

131

°

F

65

°

149

°

F

Max. temperature rise

Silver alloy

Au flash on Silver alloy

Contact material

Temperature error

Timed-out 2 Form C

Contact arrangement

Operating mode

Approx. 10VA (100 to 240V AC)

Approx. 2.5VA (24V AC)

Approx. 2W (12V DC, 24V DC, 48 to 125V DC)

Rated power consumption

Rating

Time
accuracy
           Note:)

Contact

Life

Electrical
function

Mechanical
function

Operating
condition

Others

PM4H-M

Min. 100M

(At 500V DC)

Note: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple

factor for DC), 20°C 

68°F

ambient temperature, and 1s power off time.

2) For the 1s range, the tolerance for each specification becomes ±10ms.

PM4H-A

Pin type

Timed-out 2 Form C

Screw terminal type

Timed-out contact 2 Form C

PM4H-M

Pin type

Timed-out 1 Form C

Instantaneous 1 Form C

Screw terminal type

Timed-out 1 Form C

Instantaneous 1 Form C

PM4H-S

Pin type

Timed-out 2 Form C

Screw terminal type

Timed-out 2 Form C

2) Contact

Timed-out contact

Instantaneous contact

Type

PM4H-A

PM4H-S

PM4H-M

Pin

Connect the terminal 

 to

negative (–), and the terminal

 to positive (+).

Connect the terminal 

x

 to

negative (–), and the terminal

z

 to positive (+).

Connect the terminal 

 to

negative (–), and the terminal

 to positive (+).

Screw terminal

1) DC Type

Operating

voltage

(–)

(+)

COM

N.C.

N.O.

COM

N.O.

N.C.

Stop
input

Signal
input

Reset
input

COM

COM

Stop
input

Signal
input Reset

input

(+)

(–)

N.O. N.C.

N.C. N.O.

Operating

voltage

Operating

voltage

(–)

(+)

COM

COM

N.C.

N.C.

N.O.

N.O.

COM

COM

(+)

(–)

N.O. N.C.

N.C. N.O.

Operating

voltage

Operating

voltage

(–)

(+)

COM

COM

N.C.

N.C.

N.O.

N.O.

COM

COM

(+)

(–)

N.O. N.C.

N.C. N.O.

Operating

voltage

PM4H-A/S/M

02/2003

Содержание PM4H-A

Страница 1: ...Pulse ON flicker Differential ON OFF delay 1 2 Signal OFF delay Pulse One shot Pulse One cycle Power ON delay 5 operation modes With instantaneous contact Power ON delay Power Flicker Power ON flicker Power One shot Power One cycle 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 8 pin Screw terminal 8 pin Screw ter...

Страница 2: ...and dead metal parts 2 000Vrms for 1 min Between input and output 2 000Vrms for 1 min Between contacts of different poles 1 000Vrms for 1 min Between contacts of same pole Breakdown voltage Initial value Setting error Voltage error Contact resistance Initial value 100ms Min power off time 55 C 131 F 65 C 149 F Max temperature rise Silver alloy Au flash on Silver alloy Contact material Temperature ...

Страница 3: ...pin 3 752 Din rail socket ATC18003 8 pin ATC18004 11 pin Mounting rail AT8 DLA1 45 1 772 024 0 0 6 0 45 1 772 024 0 0 6 0 Min 80 3 150 Min 80 3 150 A 45 1 772 024 0 0 6 0 A 48 n 2 5 A 1 890 n 098 024 0 0 6 0 48 1 890 66 5 2 618 14 5 571 12 0 472 48 1 890 6 0 236 41 1 614 44 5 1 752 0 PARTS NAME PM4H S PM4H A PM4H M Power indicator LED Operation indicator LED Hand Operation mode selector Selectable...

Страница 4: ...gins When the time delay is completed the output contacts change state and next time cycle begins When the time delay is completed the output contacts return to the normal state This cycle will repeat until a reset signal is applied or power is removed Note When a stop signal is applied during timing operation the time cycle stops When a stop signal is removed the time cycle begins Turn the operat...

Страница 5: ...hen a reset signal is applied or power is removed Note When a stop signal is applied during timing operation the time cycle stops When a stop signal is removed the time cycle begins Pulse One shot OS OS Differential ON OFF delay 2 OF2 OF2 Pulse One cycle OC OC PM4H S PM4H M Operation mode Operation Time chart When power is applied continuously the time cycle begins The out put contacts change stat...

Страница 6: ...Pin type 110g 3 880 oz Screw terminal type Weight Min 294m s2 4 times on 3 axes Shock resistance Min 980m s2 5 times on 3 axes 10 to 55Hz 1 cycle min double amplitude of 0 5mm 10min on 3 axes Vibration resistance 10 to 55Hz 1 cycle min double amplitude of 0 75mm 1h on 3 axes Functional Destructive Functional Destructive Between live and dead metal parts Between input and output Between contacts of...

Страница 7: ...M Star Delta switching Instantaneous contact Relay Timed out side 1 Form A side 1 Form A Instantaneous 1 Form A Relay Timed out side 1 Form A side 1 Form A Relay Timed out side 1 Form A side 1 Form A Instantaneous 1 Form A Operating voltage con tact contact Operating voltage con tact contact Operating voltage con tact con tact Operating voltage con tact con tact side time delay contact side time d...

Страница 8: ...xes Vibration resistance 10 to 55Hz 1 cycle min double amplitude of 0 75mm 1hr on 3 axes Functional Destructive Functional Destructive Between live and dead metal parts Between input and output Between contacts of different poles 3 Between contacts of same pole Insulation resistance Initial value 1 500Vrms for 1 min Between live and dead metal parts 1 500Vrms for 1 min Between input and output 1 0...

Страница 9: ...n 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 8 pin 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 20...

Страница 10: ...in screw 11 pin screw 11 pin screw 11 pin screw 11 pin screw 11 pin screw 11 pin screw 11 pin screw 11 pin screw 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 24V AC 12V DC 24V DC 3 selectable time ranges over 1s to 10s Relay Timed out 2 Form C Power OFF delay wi...

Страница 11: ...O N C N C N O Operating voltage Reset input Reset input Reset input Reset input Reset input Photo coupler Photo coupler PM4H F8R PM4H F11R PM4H F8R PM4H F11R Use a contact with good contact relia bility for the input Contact bounce can lead to erroneous operation of the timer so use a contact with short bounce time Make the resistance between terminals for a short circuit less than 1k ohms Make th...

Страница 12: ...uld be set under 0 range Instantaneous output area When power supply is on the time range setting time and operation mode cannot be changed Turn off the power supply or a reset sig nal is applied to set the new operation mode ON FL FO OF1 SF OS OF2 OC How to use Stop ring PM4H series 1 Fixed time setting Set the desired time and put 2 stop rings together Insert the rings into stopper to fix the ti...

Страница 13: ...eset signal input Connect terminals screw terminal for stop signal input Be sure not to connect with other terminals and apply excessive voltage The inter nal circuit will be damaged 6 The input wiring other than the power supply circuit should avoid these condi tions high voltage wiring and parallel wiring with power wire Wire in short with using the sealed wire or metal wiring tube 7 For operati...

Страница 14: ...V AC 48 to 125V DC Surge voltage 4 000V 12V DC 24V DC 24V AC 24V AC DC 500V No good Leak current Fig A C R T Power supply Good Fig B C R T Power supply R contacts of relay R T T Time R Relay R R Surge wave form 1 2 50 µs single polarity full wave voltage Notes for PM4H series Even if the open collector is not used input is also possible from the non con tact circuit of 6 to 30V DC In this case the...

Отзывы: