8.3.   SELECTING THE HARDWARE PLATFORM 

 

The EmberZNet stack uses a Ember

TM

 platform (Ember

TM

 breakout board and RCM  

module), which   is defined in a BOARD_HEADER file. This file is named dev0455.h  and 
located in the folder 
 ….\Ember\EmberZNet2.5.0\hal\micro\xap2b\em250\board\  
 

IMPORTANT:

 Because the use and settings of GPIOs on the PAN4570 testboard is 

different another BOARD_HEADER file is required.  
 
After installation of EmberZNet2.5.0 the required change of the BOARD_HEADER file 
can be done as follows: 
 
Rename the dev0455.h extracted with EmberZNet for example in dev0455_ember.h 
Copy the PAN4570.h file from the cd to the location where dev0455.h was located 
Rename the PAN4570.h file to dev0455.h 
 
PAN4570.h enables D11, D14, SW2 and SW6 connected to PAN4570 for the use of 
the “simple-lighting” sample application. 
 
The two switches and two LEDs are used as follows: 

 

board LED 

GPIO 

Ember

TM

 name 

function 

LIGHT D11 

HEARTBEAT_LED 

heartbeat 

LIGHT D14 

12  LIGHT 

LIGHT 

LIGHT 

SW2 

15 

BUTTON 1 

LIGHT ON and networking 

LIGHT 

SW6 

BUTTON 0 

LIGHT OFF and networking 

SWITCH 

SW2 

15 

BUTTON 1 

LIGHT ON 

SWITCH 

SW6 

BUTTON 0 

LIGHT OFF 

         (Table 

4) 

For custom applications 5 buttons and 4 LEDs are available on the testboard, the 
carrierboard/testboard schematics in part 10 show their connections to the GPIOs. 
Changes regarding the GPIOs should always be done only in the BOARD_HEADER file. 
 

 

 

 

 

 

 

Содержание PAN4570

Страница 1: ... CUSTOMER S CODE EvalPAN4570 PANASONIC S CODE DATE Datum 06 11 2006 European Technology Center Panasonic Electronic Devices EUROPE GmbH APPROVED genehmigt CHECKED geprüft DESIGNED Erstellt Manual Evaluation Board for PAN4570 Wireless Module FIGURE 1 ISM RF TRANSCEIVER TESTBOARD WITH PAN4570 AND ANTENNA ...

Страница 2: ... a power supply 6 5 2 D C power from a USB device 7 5 3 Power on 7 6 Serial Port 8 7 Reset 8 8 Operation and programming 8 8 1 Serial communication and embedded bootloader 8 8 2 Upload of EmberZNet sample applications 9 8 3 Selecting the hardware platform 10 8 4 EmberTM Insight Adaptor configuration 11 9 Ember ZigBee Implementation 11 9 1 Flash Programming of PAN4570 11 9 2 Development of Applicat...

Страница 3: ...GHz antennas with male SMA plugs 2 x RS 232 cables 2 x battery adaptors with cable for d c power supply 1 x CD with software and documentation 1 2 HARDWARE NEEDED 12 x Batteries AA size or 2 mains supplied 9Vdc sources PC with at least 1 preferably 2 free COM Ports 1 3 SOFTWARE NEEDED Microsoft Hyper Terminal or any other terminal software installed on a pc EmberZNet installed on a pc currently Ve...

Страница 4: ...t the 50Ohms 2 4GHz antenna with SMA male plug on the PAN4570 carrierboard SMA socket Check if a Vcc 2 7Vdc module supply jumper is set to the corresponding 2 pin header B or C or D Remark Instead of a jumper an amperemeter for measuring the module current on VCC can be connected to the module supply 2 pin header In this case the voltage drop at the amperemeters internal resistor reduces the Vcc v...

Страница 5: ...H APPROVED genehmigt CHECKED geprüft DESIGNED Erstellt 3 TESTBOARD LAYOUT Figure 2 ISM RF Transceiver testboard with PAN4570 and antenna power switch power supply inputs 7 9Vdc JP2 for connecting 5Vdc to carrierboards not used on PAN4570 board RESET button BDM not used Vcc voltage selector JP4 set for 2 7Vdc serial RS232 interface COM2 UART1 S1 1 and S1 3 on all others off no HW handshake input bu...

Страница 6: ...eed to Slots A B C D no JP3 Vcc setting 2 1 2 7 3 4V see Table 2 no for Vcc 2 7Vdc default JP4 Vcc setting 2 1 2 7 3 4V see Table 2 yes for Vcc 2 7Vdc default JP7 Vcc regulator output feed to A B C D yes Table 1 Position C is used as an example position B or D could be used as well An amperemeter for measuring module current can be inserted instead of the jumper 5Vdc supply independent on JP3 and ...

Страница 7: ...7 3 4Vdc see Table 1 Please note that communication via the USB connector is not possible Please take into account that when using the 5V DC feed to the 34 pin headers in combination with USB power supply the voltage is not 5V but unregulated 4 3 V DC due to the voltage drop at a protection diode connected in series on the testboard Warning Do not overload the USB power source Check for the curren...

Страница 8: ...he serial cables to 1 or 2 pc s running terminal programs for example Hyperterminal with the following communication settings 115200bps 8 parity no Stoppbits 1 no flow control After a hardware RESET and hitting the return key the terminal window of the PC connected to the RS232 interface of the ISM RF transceiver testboard should display Ember Range Test Application v2 0 Oct 1 2006 Set to channel ...

Страница 9: ... D14 turned off and the output on the terminal EVENT light off On the other device run the procedure described above using the simple lighting switch ebl instead After pressing the RESET button on the testboard the output from PAN4570 as switch is simple switch 00000000000000 offline Network init status 93 For a guide on operating simple lighting see the EmberTM document Ember EmberZNet2 5 0 app s...

Страница 10: ...uired change of the BOARD_HEADER file can be done as follows Rename the dev0455 h extracted with EmberZNet for example in dev0455_ember h Copy the PAN4570 h file from the cd to the location where dev0455 h was located Rename the PAN4570 h file to dev0455 h PAN4570 h enables D11 D14 SW2 and SW6 connected to PAN4570 for the use of the simple lighting sample application The two switches and two LEDs ...

Страница 11: ...uire a driver for USB serial This driver can be aquired from FTDI http www ftdichip com Drivers VCP htm Configure your terminal emulator with the settings 115200 baud 8 data bits n no parity 1 stop bit Flow Control None Issue the following InSight adapter commands through the terminal emulator ip_static ipaddress netmask gateway ip_dhcp off For more details see also 5 Important Press the red RESET...

Страница 12: ...and click Next In the next window named Configuration click Next After the configuration the summary should be displayed Attempted to configure Ethernet Pod address of Pod Found slave with no chip select Slave with no chip select is XAP2b Within the menue TOOLS Configure_SIF SIF_configuration you can check for the pods and slave configuration 6 On your pc create a new folder for example C PAN4570 ...

Страница 13: ... EUROPE GmbH APPROVED genehmigt CHECKED geprüft DESIGNED Erstellt The DOS entry window displays the progress of programming and finally displays SUCCESS If not check again steps 3 to 5 7 Remove the connection of the Insight Adaptor to the PAN4570 carrierboard Plug the PAN4570 carrierboard to the testboard and push RESET on the testboard PAN4570 is now ready to run the programmed software For the e...

Страница 14: ...Ethernet network connection The SIF interface cable delivered with the Insight Adaptor can directly connect to the 10 pin header named SIF on the PAN 4570 carrierboard Before connecting PAN4570 to the EmberTM Insight Adaptor study the latest EmberTM Insight Adaptor documentation The following pins of PAN4570 are connected to the signals on the debug connector of the EmberTM Insight adaptor PAN4570...

Страница 15: ... the terminal will display a complete list of commands below the mostly used commands are explained e exit leaving the last funktion channel x channel entry where x b sets the lowest channel at 2405MHz x 12 sets a channel at 2440MHz x 1a sets the highest channel at 2480MHz txtone turns on an unmodulated carrier txstream turns on a continuously modulated carrier transmit x transmission of packets a...

Страница 16: ...PAN4570 PAGE Seite 16 of 20 CUSTOMER S CODE EvalPAN4570 PANASONIC S CODE DATE Datum 06 11 2006 European Technology Center Panasonic Electronic Devices EUROPE GmbH APPROVED genehmigt CHECKED geprüft DESIGNED Erstellt 10 SCHEMATIC OF THE ISM RF TRANSCEIVER TESTBOARD 10 1 SHEET 1 ...

Страница 17: ... SUBJECT Thema EvalBoard PAN4570 PAGE Seite 17 of 20 CUSTOMER S CODE EvalPAN4570 PANASONIC S CODE DATE Datum 06 11 2006 European Technology Center Panasonic Electronic Devices EUROPE GmbH APPROVED genehmigt CHECKED geprüft DESIGNED Erstellt 10 2 SHEET 2 ...

Страница 18: ...an Technology Center Panasonic Electronic Devices EUROPE GmbH APPROVED genehmigt CHECKED geprüft DESIGNED Erstellt 10 3 PAN4570 CARRIERBOARD remarks 1 PAN4570 is programmed per X2 2 R1 R2 and R4 are not mounted 3 R3 is mounted as pulldown resistor at SIF_MOSI 10k typ X1 34 S_MOSI is connected to ground X1 33 The pulldown res at SIF_MOSI is required for deep sleep current chars ...

Страница 19: ...s Guide 23 June 2006 EmberTM 120 4002 0002D 5 InSight Adaptor Technical Specification 3 May 2006 EmberTM 120 2002 000D 6 Using the Standalone Bootloader AN5013 30 June 2006 EmberTM 120 5013 000A 7 EmberZNet Application Developer s Guide 29 June 2006 EmberTM 120 0066 0001 8 CompilingAppsEM250 9 June 2006 EmberTM 120 5018 000D 9 Developing EmberTM Applications EM250 Microprocessor EmberTM 120 5018 0...

Страница 20: ... any liability or product warranty for Engineering Samples In particular Panasonic Electronic Devices Europe GmbH waives liability for damages caused by the use of the Engineering Sample other than for Evaluation Purposes particularly the installation or integration in an other product to be sold by Customer deviation or lapse in function of Engineering Sample improper use of Engineering Samples P...

Отзывы: