Operation manual for Narrow pitch connectors P5K
Panasonic Corporation
industrial.panasonic.com/ac/e/
©
Panasonic Corporation 2017
ACCTF29E-1 201708
- 5 -
(2)
When the board fixation is not enough as the lower chart , the connector is
affected by the load of the inertial force and might be damaged.
Please consider as follows.
Shock of fall
(1) If the both boards are not fixed sufficiently,
the connector is affected by the shock and
might be damaged.
(2) If there is no gap between enclosure and sub
board
(
A
<
B
)
, the sub board strikes against
the enclosure. Due to the impact of its strike,
the connector is affected and might be
damaged.
<Prevention>
Please fix the both main and sub-board
sufficiently
(1) Fix the main board
(Fix the side that has the larger mass and
prevent the inertial motion of drop impact.)
(2) Hold with object such as rubber cushion
not to move by the drop impact.
(3) Guide of the board is to be A
≧
B, to
prevent the damage of the gap made by drop
impact.
×
A<B
○
A
≧
B
Sub-board
(FPC)
Connector
Enclosure
Main board
(not fixed)
Connector
Enclosure
Main board
(fixed)
Object to hold
Sub-board
(FPC
)
<Prevention>