03. Precautions during mounting –to- reflow
03-1. Mounters
We recommend that you select a multi-function mounter to mount connectors.
Even if you select a high-speed mounter, please use a multi-function head and load
control.
03-2. Precautions for selecting a pickup nozzle for
mounting connectors
Select a pickup nozzle with a pickup area that provides a theoretical lift force
10
times
greater than the connector’s weight.
Theoretical lifting force (gr) = Vacuum pressure (mmHG) /760
×
1.033
×
Nozzle
area (cm
2
)
Sample vacuum pressure of machines: 480 to 520 mmHG
Shape of nozzle
Size of pickup face
Socket
Header