3. If the reading is out of specification, make sure that there is no
dust or foreign material between the Brake Pad of Tension Control
Arm Unit and the S Reel Table.
After cleaning, the reading of tension measurement is still out of
specification, replace the Tension Arm Unit and the Tension
Control Arm Unit.
Fig. M2-2
Note:
1. Be sure that the three probes of the meter are all in solid contact
with the tape, but not touching any other parts of the mechanism.
2. It is recommended that measurements should be repeated at least
three (3) times because the tension meter is very sensitive to
external vibrations.
6.2.2.2. TAPE INTERCHANGEABILITY ADJUSTMENT
Note:
To perform these adjustment/confirmation procedures, enter the
Tracking center mode.
Equipment Required:
Dual Trace Oscilloscope
38
Содержание NV-FJ6130PN
Страница 6: ...Fig 1 4 Fig 1 5 6 ...
Страница 22: ...5 2 3 EJECT Position Confirmation Fig J1 2 22 ...
Страница 48: ...10 2 MECHANISM BOTTOM SECTION 48 ...
Страница 49: ...10 3 CASSETTE UP COMPARTMENT SECTION 49 ...
Страница 50: ...10 4 CHASSIS FRAME AND CASING PARTS SECTION 50 ...
Страница 51: ...10 5 PACKING PARTS AND ACCESSORIES SECTION 51 ...
Страница 56: ...11 2 MECHANICAL REPLACEMENT PARTS LIST MECHANICAL REPLACEMENT PARTS 56 ...
Страница 96: ......
Страница 97: ......