3. PERFORMANCE DATA
3.1 NR-CY54AG, NR-CY557G
-Cooling performance by Temperature control
Control Setting
Coldest
Medium
Warmest
Mean Fresh Food compartment Temp.
t3 (°C)
2.0 ± 2.5
3.5 ± 2.5
6.0 ± 2.5
Mean Freezer Load Temp.
(°C)
-22.0 ± 2.5
-20.0 ± 2.5
-15.0 ± 2.5
Vegetable Crisper Temp.
(°C)
-
4.0 ± 2.5
-
PC Door Shelf Upper Temp.
(°C)
-
6.5 ± 2.5
-
Egg Tray Temp.
(°C)
-
3.0 ± 2.5
-
PC Door Shelf Bottom Temp.
(°C)
-
5.0 ± 2.5
-
Chill Case Temp.
(°C)
-
0.0 ± 2.5
-
Running Ratio
(%)
85 ± 15
80 ± 15
60 ± 15
Power Consumption
(kWh/Day)
-
2.2 or under
-
* Under On - load and ambient temperature 32 ± 1°C
3.2 ECONAVI
-Cooling performance by ECONAVI control
Control Setting
AT32°C
Mean Fresh Food compartment Temp.
t3 (°C)
-
4.0 ± 2.5
-
Mean Freezer Load Temp.
(°C)
-
-18.0 ± 2.5
-
Vegetable Crisper Temp.
(°C)
-
5.0 ± 2.5
-
PC Door Shelf Upper Temp.
(°C)
-
7.0 ± 2.5
-
Egg Tray Temp.
(°C)
-
4.0 ± 2.5
-
PC Door Shelf Bottom Temp.
(°C)
-
6.5 ± 2.5
-
Chill Case Temp.
(°C)
-
1.0 ± 2.5
-
Running Ratio
(%)
-
70 ± 15
-
* Under On - load and ambient temperature 32°C