10.2 Cool, not enough [ Both PC & FC (compressor operates) ]
To con
fi
rm when compressor is operating.
1
When FC door opens and FC door
SW pushes, does cold air spout out
from exhaust?
2
When PC door opens and PC door
SW pushes, does cold air spout out
from exhaust?
4
Does “ECONAVI Led” and “Quick
Freezing” turn on?
5
Does “ECONAVI Led” turn off and
“Quick Freezing” turn on?
7
Does “ECONAVI Led” turn off and
“Quick Freezing” turn off?
9
Does “ECONAVI Led” and “Quick
Freezing” blink?
6
Does thermal
fuse blow
out?
8
Does thermal
fuse blow
out?
4
Does “ECONAVI Led” turn off and
“Quick Freezing” blinking?
3
To start self diagnosing function by
opening PC door and FC door and
pushing “Quick Freezing” SW for 5
seconds.
• Defect of FC fan motor.
• Poor connection between FC fan
motor and IC 1 on PCB.
• Defect of FC door SW.
• Defect of damper.
• Defect of PC door SW.
• Defect of FC fan motor.
• Poor connection between FC fan motor
and IC 1 on PCB.
• Short of DFC thermistor.
• Poor connection between DFC
thermistor and IC 1 on PCB.
• Break of DFC thermistor.
• Defect of PCB as like as defect of relay,
etc.
• Defect of communication circuit and
EEPROM circuit of control PCB.
• Plug out and after 7 minute plug in
again.
• Break of DFC thermistor.
• Poor connection between FFC
thermistor and IC 1 on PCB.
• Termal fuse blows.
• Abnormal of spec of DFC thermistor.
* When resistor of thermistor is bigger
as like as 6.1 - 6.7K
Ω
at 0°C, there is
some case to blow thermal fuse out
due to becoming defrost time longer.
• Break of FCC thermistor.
• Poor connection between FCC
thermistor and IC 1 on PCB.
• Abnormal of spec of DFC thermistor.
* Resistor of thermistor is bigger as like
as 5.9 - 6.5 K
Ω
at 0°C
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
YES
YES
YES
NR-CY54AG_CY557G.indd 15
NR-CY54AG_CY557G.indd 15
6/27/2559 BE 4:44 PM
6/27/2559 BE 4:44 PM
Содержание NR-CY54AG
Страница 18: ... 18 11 SCHEMATIC DIAGRAM Wiring Diagram WINDING RESISTANCE VALUE U W 8 44 Ω U V 8 44 Ω W V 8 44 Ω ...
Страница 28: ... 28 13 3 Notes of Wire Connected Work Scotch Lock ...
Страница 29: ... 29 13 4 Temperature Control Device ...
Страница 30: ... 30 13 5 Phenomenon of Defective Sensor Thermal Fuse Thermal fuse ...