25
9.1.3.
The display sign list of self diagnosis code
Signal
Symptom
Check point
Condition
Display release
U10
Warning that door is kept open. 1. Close compartment door completely The sign is displayed when PC /
FC door is kept open for more
than 1 minute.
Close the door
2. Door SW PCB
Adjust door
3. Door aliment
Replace door SW PCB
4. Control PCB
Replace control PCB
H01
FC temperature sensor circuit
has trouble.
1. Sensor FC
Open or short
Replace parts
2. Sensor FC circuit
3. Control PCB
H02
PC temperature sensor circuit
has trouble.
1. Sensor PC
Open or short
Replace parts
2. Sensor PC circuit
3. Control PCB
H05
Sensor DEFROST circuit has
trouble.
1. Sensor DEFROST
open or short
(Note) When DFC is opened,
thermarl fuse is blown because
of too long defrosting time.
Replace parts
2. Sensor DEFROST circuit
3. Control PCB
4. Thermal fuse*
H07
Sensor ATC circuit has trouble. 1. Sensor ATC
Open or short
Replace parts
2. Sensor ATC circuit
3. Control PCB
4. Operation PCB
H10
SSC, Vegetable compartment
sensor circuit has trouble.
1. Sensor SC circuit
Open or short
Replace parts
2. Control PCB
H29
FC Fan Motor disconnection /
Lock
1. Fan motor circuit
Open or short
Replace parts
H31
FC defrost heater circuit has
trouble.
1. FC defrost heater
Temperature of defrost Sensor
does not reach cut-off tempera-
ture.
Replace parts
2. Thermal fuse
3. Control PCB
H35
Refrigerating unit has trouble.
(Gas leakage at high pressure
side / Poor compression)
1. High pressure side
Even if compressor runs, FC
temperature and PC tempera-
ture would not fall any more.
Replace parts
2. Compressor
H36
Refrigerating unit has trouble.
(Gas leakage at low pressure
side)
1. Low pressure side
“H40” and “H36” display repeat-
edly.
Replace parts
H38
Fan Motor has trouble.
1. Fan Motor
Fan Motor doesn't rotate.
Replace parts
2. Control PCB
H40
IPM & Compressor Protection
Control work.
1. Control PCB
Over current flow into IPM for a
long time
Replace parts
2. Compressor
H41
Under voltage protection con-
trol work.
1. Power supply voltage
Low voltage add to unit for a
long time.
Replace parts
2. Control PCB
H50
Communication error
1. Control PCB
Micro- computer can not read or
write the data.
Replace parts
2. Operation PCB
3. Wire circuit between control PCB and
operation PCB
H51
Control PCB has trouble.
1. Control PCB
Emulation initialization judge-
ment error when power supply is
turned on.
Replace parts
H52
Control PCB has trouble. (Volt-
age to compressor)
1. Control PCB
Inverter voltage is too high.
Inverter voltage is too low.
Replace parts
H79
Overload protection control
work.
1. Control PCB
Overload is detected for 5 times
continuously.
Replace parts
2. Each load
Содержание NR-B32FW3
Страница 6: ...6 3 General Introduction 3 1 Flow of Refrigerant And Air ...
Страница 7: ...7 4 Features 4 1 Features 4 1 1 High Efficiency Cabinet ...
Страница 8: ...8 4 1 2 Storage Solution ...
Страница 9: ...9 4 1 3 Refrigerator Compartment 4 1 4 Hygiene Active and Multi Airflow ...
Страница 10: ...10 4 1 5 Vegetable Case 4 1 6 Vitamin Safe ...
Страница 11: ...11 4 1 7 Hygiene Active ...
Страница 18: ...18 6 2 Components ...
Страница 19: ...19 7 Installation Instructions 7 1 Installation Instructions ...
Страница 20: ...20 ...
Страница 21: ...21 7 2 Setting the temperature ...
Страница 22: ...22 7 3 Using the handy functions ...
Страница 27: ...27 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Страница 28: ...28 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Страница 29: ...29 10 3 FC is poor cooling Compressor run ...
Страница 30: ...30 10 4 VC is poor cooling or excessive cooling ...
Страница 48: ...48 12 Maintenance ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...51 13 Dimensions 13 1 Outside ...
Страница 52: ...52 13 2 Inside ...