7.5. SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOOTING
Purpose:
Simple way
(3/23 seconds rule)
of identifying whether it’s Magnetron, Inverter or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 23 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace
H.V.Inverter
(F606Y9X90AP)
2. D702 is OK
Replace
magnetron
Shut off in 3 seconds
after “Start”
1. Less than 0.5A
Check open circuit: Interlock Switch,
DPC, Power Relay and CN701
Replace
defective
component(s),
or
correct switch, cables and connectors.
7.6. H.V.INVERTER BOARD MAIN PARTS LIST (F606Y9X90AP)
Ref. No.
Part No.
Part Name & Description
Pcs/Set
Remarks
DB701
B0FBCR000004
BRIDGE DIODE
1
20A,600V
L701
F5020W100AP
CHOKE COIL
1
Q701
B1JAGV000017
TRANSISTOR SI
1
1150V
T701
F609A8X00AP
H.V. TRANSFORMER
1
Including:C706,C707,D701,D702
C701
F0C2H284A020
CAPACITOR
1
0.28µF/600VDC
C702
F0C2E455A331
CAPACITOR
1
4.5µF/250VDC
20
NN-SE284S / NN-SE284B / NN-SE284W
Содержание NN-SE284B
Страница 2: ...2 NN SE284S NN SE284B NN SE284W ...
Страница 3: ...3 NN SE284S NN SE284B NN SE284W ...
Страница 5: ...1 SCHEMATIC DIAGRAM 5 NN SE284S NN SE284B NN SE284W ...
Страница 21: ...8 EXPLODED VIEW AND PARTS LIST 8 1 EXPLODED VIEW 21 NN SE284S NN SE284B NN SE284W ...
Страница 29: ...9 DIGITAL PROGRAMMER CIRCUIT 9 1 SCHEMATIC DIAGRAM 29 NN SE284S NN SE284B NN SE284W ...
Страница 30: ...30 NN SE284S NN SE284B NN SE284W ...