9.4. Trouble related to Digital Programmer Circuit
SYMPTOM
STEP
CHECK
RESULT
CAUSE/CORRECTIONS
No display when oven is first plugged
in
1
Fuse pattern of D.P.C.
Normal
→
Step2
Open
Replace D.P.C. or Fuse
Pattern
2
Low voltage transforment (L.V.T.)
secondary voltage
Abnormal 0V
L.V.T.
Normal
→
Step3
3
IC10 pin5 voltage
Abnormal
IC10
Normal=5V
IC1, CX320, Display
No key input
1
Membrane switch continuity
Abnormal
Membrane switch
Normal
IC1
No beep sound
1
IC1 pin 38 voltage
Abnormal
IC1
Normal=5V
BZ210, Q210
Power relay (RY7) does not turn on
even though the program had been set
and the [Start] button is tapped
1
IC1 pin 37 voltage while operation
Abnormal
IC1
Normal=5V
→
Step2
2
Short circuit IC220 pin10 to “0V“
Still not turn on
RY7
RY7 turns on
IC220
No microwave oscillation at any power
1
IC1 pin 34 voltages while operation at high
power
Abnormal
IC1
Normal=5V
→
Step2
2
Short circuit IC220 pin13 to “0V“
Still not turn on
RY3
RY3 turns on
IC220
Dark or unclear display
1
Replace display and check operation
Normal
Display
Abnormal
IC1
Missing or lighting of unnecessary
segment
1
Replace IC1 and check operation
Normal
IC1
Abnormal
Display
H95/H97/H98 appears in window and
oven stops operation.Program High
power for 1 minute and conduct
following test quickly, unless
H95/H97/H98 appears and oven stops
1
Unplug CN702 (2 pin) connector and
measure voltage between terminals
Abnormal=0V
1. Latch Switch
2. D.P.C. /Power Relay
Normal=220~240V
→
Step2
2
Unplug CN701 (3 pin) connector and
measure pin3 voltage
Abnormal=0V
D.P.C.
Approx. AC 3V
Magnetron
9.5. Simple way of H.V. Inverter/magnetron troubleshooting
Purpose:
Simple way
(3/37 seconds rule)
of identifying whether it’s Magnetron, Inverter or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 37 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace
H.V.Inverter
(F606YM300BP)
2. D702 is OK
Replace
magnetron
Shut off in 3 seconds
after “Start”
1. Less than 0.5A
Check open circuit: Latch Switch, DPC,
Power Relay and CN701
Replace
defective
component(s),
or
correct switch, cables and connectors.
27
NN-GS597M
Содержание NN-GS597M
Страница 2: ...2 NN GS597M ...
Страница 3: ...3 NN GS597M ...
Страница 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN GS597M ...
Страница 6: ...3 SCHEMATIC DIAGRAM 6 NN GS597M ...
Страница 29: ...10 EXPLODED VIEW AND PARTS LIST 10 1 EXPLODED VIEW 29 NN GS597M ...
Страница 36: ...11 DIGITAL PROGRAMMER CIRCUIT 11 1 SCHEMATIC DIAGRAM 36 NN GS597M ...
Страница 37: ...37 NN GS597M ...