20
12.3 roubleshooting (other problems)
12.4 roubleshooting the inverter (U) & magnetron
. This oven is programmed with a self diagnostics failure code system which will help for troubleshooting.
H95, H97, H98 and H99 are the provided failure codes to indicate magnetron and inverter circuit problem areas.
This section explains failure codes of H95, H97, H98 and H99. First, you must program the DPC into TEST MODE,
Press Timer pad twice - Press Start pad once - Press Timer pad once - Press Micro Power pad once. Program unit
for operation. H95, H97, H98, H99 appears in the display window a short time after the start key is pressed and
there is no microwave oscillation.
12.5 Troubleshooting the inverter (U) & magnetron
Symptom
Cause
Correction
1. Microwave output is low.
Oven takes a long time to cook food.
1. Decrease in power source volt-
age.
2. Open or loose wiring of magne-
tron filament circuit causing inter-
mittent oscillation.
3. Ageing of magnetron
Consult electrician.
Refer to output test procedures.
Change magnetron
2. Loud Buzzing noise can be heard.
1. Loose fan or fan motor
3. Turntable motor does not rotate.
. Open or loose wiring of turntable
motor.
2. Defective turntable motor
4. Oven stops operation during cooking
cycle.
1. Open or loose wiring of primary
and secondary latch switch.
Adjust door and latch switches.
5. Oven returns to “plug in” state 9
seconds after the start pad is
pressed in sensor cooking mode.
1. Open steam sensor circuit.
2. Defective steam sensor.
6. Oven lamp and turntable motor
turn-on when the microwave oven is
plugged in with the door closed.
1. Maladjusted or loose wiring of
secondary latch switch.
2. Defective secondary latch switch.
Adjust door and latch switches.