7.2 Standard Self-Diagnosis Function (Abnormal Information)
Display Part
An abnormal
Contents
Detected Contents
When a water level sensor doesn’t
detect reset water level, even if it
passes from a drainage start for
12 minutes. But it opens and
closes a drainage valve every 4
minutes.
Open and close the
cover.
Drainage is
abnormal.
• Confirm and adjust blocking of the
drainage course such as a cock
valve, a drainage hose and a
drainage pipe of the house.
• Confirm and adjust the rise of the
drainage hose and the extension
dimensions.
• Confirm and exchange of the
sensor circumference including
the water level sensor, air tube.
• Please close a cover.
A check procedure /
Measures
A cancellation
Method
※
It displays automatically when it detected an operation mistake or an abnormality during operating.
Then stop the operation.
※
※
The indication of the abnormality detection displays alphabet (U or H) and a number in turn.
( For U11 )
※
Buzzer alert is performed for all of U displaying and only H21.
NA-FS80X1 / FS90X1
“ U ”
“ 11 ”
In case of cover open, even if
washing passes from a start for 2
minutes.
Close the cover.
Cover open is
abnormal.
※
※
When a cover open.
• The exchange of the controller
(a lead switch) for displaying.
※
When a cover close.
In case of cover open, when
spinning starts.
※
• Please correct it.
When an ambalance is detected
during centrifugal force washing
and spinning.
Open and close the
cover.
Ambalance is
abnormal.
※
※
Are cloths clustered?
• Please adjust level.
※
Is the machine inclined or
wobbled?
• Check water supply and the faucet
open. And adjust it.
• Check and exchange of the water
supply valve and load side
controller.
After water supply start, water
level doesn’t reach to the setting
water level even if it passes for
30 minutes.
Open and close the
cover.
Water supply is
abnormal.
※
※
After water supplement in wash
sequence, water level doesn’t
reach to the setting level even if
it passes for 20 minutes.
※
Without water supply.
• Check water leak from the cock
part and adjusting it.
• Check water leak from other parts
and adjusting it.
• Check proper plug connection.
• Replacement of the water level
sensor.
• Replace of the load side controller.
• Noise • Electric wave obstacle.
※
With water supply.
-
Hold [course] button
more than 5 sec.
Child lock
operation.
※
In the case of the child lock [on],
after power supply button is [on],
it shows [CL] on the remaining
time display for 2 seconds.
When the input frequency of the
water level sensor is out of an
appointed range.
Push [power off]
button.
Water level
(pressure) sensor
is abnormal.
※
• Replace a controller of the load
side.
When it detected a short circuit of
the power supply relay in the load
controller.
Pull a power plug out.
Power switch
relay short is
abnormal.
※
• Replace a controller of the load
side.
When wiring data into memory
was not possible. Only in service
check B.
Push [power off]
button.
Access to
microcomputer
memory is
abnormal.
※
• Check connector contact of the
rotary sensor and breaking
lead wire.
• Replacement of the machine
motor.
• Replace a controller of the load
side.
When there isn’t input signal from
a rotary sensor at the time of a
motor ON sequence.
Push [power off]
button.
Rotary sensor
is abnormal.
※