![Panasonic NA-FS80X1 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/panasonic/na-fs80x1/na-fs80x1_service-manual_281983021.webp)
- 21 -
NA-FS80X1 / FS90X1
6 Confirm Level
7 Perform test operation to check water leak, abnormal sound and error alart.
Check a Level Meter
Adjust Inclination
(Front)
(Front)
(view from the bottom)
Bubble
h
orizon
●
No need for adjustment
●
Raise
●
Install rubber sheet.
●
Install rubber sheet.
■
In case of protrude greatly
■
Adjusting inclination
■
Open a faucet and operate after closing a cover
(don't put anything in the tank!).
■
Adjust it with an adjustment leg (one place of right front part)
■
Install an attached adjustment rubber
sheet to adjust for the other case.
1
Loosen an adjustment leg knob.
2
Turn an adjustment leg to adjust inclination.
3
Tighten an adjustment leg knob to fix it.
●
Install rubber sheet.
Wood plate, etc.
●
Raise
●
Install rubber sheet.
●
In case for gathering of bubble is slant : please adjust to similar position as above with an
adjustment leg. Then adjustment leg. Then adjust in details.
●
Adjustment rubber sheet
●
Stacking up (10mm)
●
Indicates abnormal for following cases.
Level Meter
Put a board under the
leg of the other side to
decrease protrude.
Then adjust in details.
Back is
h
igh
Right is
h
igh
Front is
h
igh
Left is
h
igh
Loosen
※
Adjustment rubber sheet cannot be installed to an adjustment leg.
Tighten
Adjustment leg knob
Higher
Lower
Adjustment leg
5 mm
1
2
3
Holding Course + Good Quality House laundry
button and push Power on button.
Push Course button during is displayed.
Remaining time (4min) is displayed and starts
operation. (Operation stops automatically after 4min)
5 mm
・
The rise of the drainage hose is higher than 10cm
・
The drainage hose is not connected correctly.
・
The drainage hose is clogged.
・
Water supply hose is connected but a faucet is not opened.
Install a bigger one upper side.