33
11.9. Circulation Pump
The component is used for circulation of water inside the
drum in order to increase washing performance.
Circulation Pump
Technical features
Nominal voltage
220 - 240 V
Frequency 50
Hz
Resistor (coil)
169,5
Ω
(±5%)
Testing component
Check the resistance value on the component with multimeter as shown below.
Resistance value should be between 160- 180
Ω
You can determine the ohm value by measuring from the red cable at 5th and red cable at 12th position in the small socket
(refer wiring diagram in section 12) as shown below figure. Resistance value should be between 160- 180
Ω
Component test
5
th
pin Red Cable
12
th
pin Red Cable
Содержание NA-147VB6WGB
Страница 2: ...2 ...
Страница 4: ...4 2 3 Dimension in millimetres NA 147VB6 ...
Страница 5: ...5 3 Location of Controls and Components ...
Страница 9: ...9 5 2 Program Details ...