33
11.8. Circulation Pump
The component is used for circulation of water inside the
drum in order to increase washing performance.
Circulation Pump
Technical features
Nominal voltage
220 - 240 V
Frequency
50 Hz
Resistor (coil)
169.
5 Ω (±5%)
Testing component
Check the resistance value on the component with multimeter as shown below.
Resistance value should be between 160-
180 Ω
You can determine the ohm value by measuring from the red cable at 5th and red cable at 12th position in the small socket
(refer wiring diagram in section 12) as shown below figure. Resistance value should be between 160 -
180 Ω
Component test
5
th
pin Red Cable
12
th
pin Red Cable
Содержание NA-127VB6WAE
Страница 2: ...2...
Страница 4: ...4 2 3 Dimension in millimetres NA 127VB6...
Страница 5: ...5 3 Location of Controls and Components...
Страница 9: ...9 5 2 Program Details...
Страница 34: ...34 12 Wiring Diagram Board...
Страница 35: ...35 12 1 Wiring Diagram Socket...
Страница 39: ...39 13 3 Washing Group Spare Parts 13 3 1 Exploded View of Washing Group Spare Parts...
Страница 43: ...43 13 6 Body Group Spare Parts 13 6 1 Exploded View of Body Group Spare Parts...
Страница 47: ...47 13 9 Accessories 13 9 1 Accessories 995 996 997 998 994...
Страница 49: ...49 13 10 Packaging Group Spare Parts 13 10 1 Exploded View of Packaging Group Spare Parts...