IR Remote Signal Receiver
IR Remote Signal Receiver Operation
Panasonic Semiconductor Development Company
MN102H75K/F75K/85K/F85K LSI User Manual
222
Panasonic
8.3.6
Controlling the SLOW Mode
Use bit 7 (SP) in the RMLD reg-
ister to toggle the noise filter
sampling frequency between
PWM6/PWM8 and PWM3/
PWM5.
The MN102H series microcontrollers have two operating modes: NORMAL and
SLOW. (See section 3.1, “CPU Modes,” on page 72.) In SLOW mode, f
SYSCLK
= 2 MHz, which affects the frequencies of the PWM3 clock and noise filter
sampling (PWM6/PWM8). Use the SPSLW bit (bit 6) of the RMLD register to
change which clocks and noise filter sampling that you use.
Table 8-4 Differences between SLOW and NORMAL Modes
SPSLW
(RMLD,
bit 6)
Normal Mode
(f
SYSCLK
= 12 MHz)
SLOW Mode
(f
SYSCLK
= 2 MHz)
Noise filter sampling
Clock
Noise filter sampling
Clock
0
PWM6
(21.3 µs)
PWM8
(85.5 µs)
PWM3
(2.7 µs)
PWM6
(128 µs)
PWM8
(512 µs)
PWM3
(16 µs)
1
PWM3
(2.7 µs)
PWM5
(10.7 µs)
PWM1
(0.67 µs)
PWM3
(16 µs)
PWM5
(64 µs)
PWM1
(4.0 µs)