background image

7

6

Name of part

Name of  part

Brushless amplifier

50 W, 100 W

[front view]

[side view]

connector for motor connection

(MOTOR)

Power LED (PWR)

(green: when power is ON)
Alarm  LED (ALM)

(red: when Trip is operation*)

connector for Communications

(SER)
connector for power input

(POWER)

connector for control signals (I/O)

Attachment hole

Grounding

terminal

screw 

105

4.3

10

35

21

21

10

5.2

120

130

140

Φ5.2

[Unit: mm]

75

* The meaning of  "trip" is that a protection circuit operates and stops. 

200 W, 400 W, 750 W

[front view]

[side view]

connector for motor connection

(MOTOR)

Power LED (PWR)

(green: when power is ON)
Alarm  LED (ALM)

(red: when Trip is operation*)

connector for Communications

(SER)

Terminal for power supply input (POWER)

* The meaning of  "trip" is that a protection circuit operates and stops. 

connector for control signals 

(I/O)

Grounding

terminal

screw 

[Unit: mm]

120

75

68

6.5

5.2

20

4

4

138

150

ø5.2

Attachment hole

Installation

Install the brushless amplifier properly for preventing failure and accident.

Transport

• Use caution enough in transporting the unit to prevent injury by drop or fall, and avoid damage 

to the equipment.

Storage

• Keep the unit indoors in a clean and dry place free from vibration with little change of 

temperature.

• In keeping a gear head alone, direct the output shaft down.

 

(Otherwise, grease leaking is possible.)

Location

• Location gives great influence upon the life of brushless amplifier, therefore choose a place in 

conformance with the conditions below:

(1) Indoors where the motor is not subjected to rain water and direct sun beam.

(2) Do not use the motor in corrosive atmosphere such as hydrogen sulfide, sulfurous acid, 

chlorine, ammonia, sulfur, gas chloride, gas sulfide, acid, alkali, and salt, in the atmosphere 

of combustible gas, or in the vicinity of flammables.

(3) Place not exposed to grinding liquid, oil mist, iron powder, and cutting particle.

(4) Well-ventilated place with little moisture, oil, or inundation, and place far from heat source 

such as a furnace.

(5) Place easy to check and clean

(6) Place free from vibration

(7) Do not use the unit in an enclosed environment. Enclosing may raise the temperature of 

motor (amplifier), and shorten their life.

Environmental condition

Item

Condition

Ambient temperature

0 ℃ to 50 ℃ (free from freezing) 

*1

Ambient humidity

20 to 85 % RH (free from condensation)

Storage temperature

At normal temperature and normal humidity

*2

Protection structure

Equivalent to IP20

Vibration

Not greater than 5.9 m/s

2

 (10 to 60 Hz)

Altitude

Not greater than 1000 m

*1 Ambient temperature is measured at a distance of 5 cm 

from the product.

*2 Temperature which is acceptable for a short time, such as 

during transportation, is –20 ℃ to 60 ℃ (free from freezing).

How to Install

Vertical

Location of fixing screw    

Location of fixing screw    

The amplifier is a vertical placement type. Install it vertically 

and provide at least 10 cm space around it for ventilation.

(1) When installing with screw

Determine the fastening torque of the fixing screw based on 

the strength of the screw and material of the mounting surface, 

to ensure secure and safe installation.

Example: 

  To install to steel plate with steel screw (M4): 1.35 to 1.65 N

m

(2) When installing to DIN rail (50 W, 100 W)

The DIN rail mounting unit is available as option.

For details, refer to the Instruction Manual (Overall).

50 W

100 W

200 W

400 W

750 W

Содержание MINAS-BL KV Series

Страница 1: ... after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of this product please be sure to read the instruction Manual Overall from our Web Site Web address of Panasonic Corporation http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html This product image is 200 W type o...

Страница 2: ...urrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and checking must be performed with power source turned off and after making sure that there is no risk of electric shock The failure could result in electric shocks or injuries Do not subject the product t...

Страница 3: ...ght this product Checking the model of Amplifier and Motor This amplifier is designed for use in combination with a motor to be specified by us Check a name of series rated output voltage specifications you wish to use You must not use any other combinations than those listed below Standard Voltage Out put Amplifier Type Applicable Motor Single phase AC100 to 120 V 50 W MBEK5A1BCV MBMS5AZBL 100 W ...

Страница 4: ...otor in corrosive atmosphere such as hydrogen sulfide sulfurous acid chlorine ammonia sulfur gas chloride gas sulfide acid alkali and salt in the atmosphere of combustible gas or in the vicinity of flammables 3 Place not exposed to grinding liquid oil mist iron powder and cutting particle 4 Well ventilated place with little moisture oil or inundation and place far from heat source such as a furnac...

Страница 5: ...supply outside of equipment from MCCB use an electric wire of 1 6 mm diameter 2 0 mm2 or more both for main circuit and grounding Apply grounding class D 100 Ω or below for grounding Do not tighten the ground wires together but connect them individually Fastening torque of earth screws to be 0 49 to 0 98 N m For details of parameters refer to the Instruction Manual Overall For the wiring of commun...

Страница 6: ...ation Connection of digital key pad of an option is possible digital key pad connecting cable of an option DV0P383 is required The terminal number of a modular jack is the following figure 8 1 Refer to operation manual Overall for the correspondence procedure of RS485 1 Do not connect anything 2 5 V DC5 V power supply for digital key pad 3 SOT Interface for digital key pad or PANATERM for BL 4 SIN...

Страница 7: ...fier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V to 120 V 10 50 60 Hz 200 V system Single phase 3 phase 200 V to 240 V 10 50 60 Hz Use the equipment under the environment of overvoltage category II specified by IEC60664 1 In order to obtain overvoltage category III insert ...

Страница 8: ...void inputting a supply voltage which significantly exceeds the rated range to the power supply of this product Failure to heed this caution may result in damage to the internal parts causing smoking and or a fire and other trouble Item Specifications Model name Brushless amplifier MBEK 5A1BCV MBEK 5A5BCV MBEK 011BCV MBEK 015BCV MBEK 021BCV MBEK 025BCV MBEK 045BCV MBEK 083BCV Brushless motor MBMS5...

Страница 9: ... can be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany 7 1 1 Morofuku Daito Osaka 574 0044 Japan Phone 81 72 871 1212 For your records The model number and serial number of this product ...