Panasonic MC-V210 03 Скачать руководство пользователя страница 5

-5-

EXPLODED VIEW 

(NOZZLE HOUSING)…       BLOCK

A

B BLOCK

A-11

A-14

A-1

A-10

A-20

A-17

A-20

A-15

A-12

A-7

A-2

A-3

A-8

A-16

A-8

A-18

A-19

A-19

A-4

A-5

A-6

A-5

A-6

A-6

A-21

A-13

A-9

-16-

HOSE REPLACEMENT

MOTOR PROTECTOR REPLACEMENT

Removal

1.

Remove the dust cover and dust bag.

2.

Remove the motor protector (shown in the 

C Block

) by pushing in, one at a time, on the tabs that secure it to the dust

compartment.   Push the motor protector out the back of the dust compartment.

Disassembly

1.

Holding a pair of needle nose pliers at an angle and in a position where one side

of the pliers is against the locking tab, exert enough pressure on the tab to release

it, (see 

Fig. 12

).  

NOTE:  There are two locking tabs present, but only one

needs to be released.  For reassembly look at the exploded view in the C

Block.

Installation

1.

Reinstall the motor protector into the dust compartment by aligning the two tabs

under the top flange with the slots in the dust compartment and applying pressure

until it snaps into place.

(Fig. 12)

Installation

1.

Insert the new power cord (power cord replacement only) into the dust compartment as far as necessary in order to place

a new cord retainer in proper location on power cord.  The proper location is approximately one and one eighth inches/thirty

millimeters (1 1/8”/30 mm) of new power cord outer jacket extending past the cord retainer and washer.  The washer goes

between the cord retainer and the dust compartment.  Attach wires with wire connectors according to the wiring diagram in

the front of this manual.  

ONLY USE A NEW CORD RETAINER, DO NOT REUSE A CORD RETAINER.

2.

For switch replacement only, insert the new ON/OFF switch with the numbers 1,2,3, facing toward you, into the dust 

compartment until secured by the retaining tabs.  Use a wire tie with the part number listed in the 

C Block 

parts list and 

place it in the location shown in 

Fig. 10 

taking care not to overtighten it.  Tuck the wire connectors back into the dust

compartment as shown in the close-up view in 

Fig. 10

.

3. 

Ensure that the Insulator Packing is installed correctly, 

(see Fig. 11)

.

4.

Replace the switch cover, the two (2) switch cover screws, and the dust cover.  Care should be taken not to pinch wires

and make sure that the switch cover goes on easily and stays flat.  If there is resistance to the switch cover lying flat and in

place, stop, remove the cover and make sure that no wires are being pinched.  

DO NOT USE A POWER SCREWDRIVER

TO SECURE THE COVER.

NOTE:  Any service involving the handle or switch cover area should be followed up with a dielectric or current

leakage check of the unit.  If you do not have the equipment or are not familiar with the test procedures, take the

unit to an authorized servicer.  

POWER CORD/ON-OFF SWITCH REPLACEMENT (Cont.)

Removal

1.

Remove the lower plate as instructed in the LOWER PLATE REMOVAL/INSTALLATION section.  

2.

Pull the hose up out of the nozzle housing.  Push the hose out of the back of the nozzle housing.  

3.

Pull the end of the hose out of the suction inlet.

Replacement

1.

Replace the new hose by screwing it counterclockwise into the suction inlet.

2.

Insert the hose in through the back of the nozzle housing.  Push the end of the hose down into the slot in the nozzle.

3.

Replace the lower plate as described in the LOWER PLATE REMOVAL/INSTALLATION section.

Содержание MC-V210 03

Страница 1: ...ATIONS Model MC V210 03 Power Source AC 120V 60 Hz Power Consumption 10 0 Amps Cord Length 50 Ft Motor Protector Yes Height Adjust 4 Position Weight 16 0 lbs PANASONIC CONSUMER ELECTRONICS COMPANY DIVISION OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA One Panasonic Way Secaucus New Jersey 07094 World Wide Web Address http www panasonic com Printed in U S A PANASONIC SALES COMPANY DIVISION OF MATSU...

Страница 2: ...s of the power cord plug and operate the ON OFF switch If the meter indicates continuity the AC cord switch motor winding are OK If no continuity is found proceed as follows Remove dust cover and the switch cover short across AC plug ends open the ON OFF switch and read across the black and white leads of the AC cord If continuity cord is OK If no continuity AC cord is open Replace AC cord Motor c...

Страница 3: ... wrench still The nut will have to be turned clockwise as it is a left hand thread After removing the nut remove the fan Fig 17 There is a spacer left on the motor that is not required to be removed If spacer is removed reassemble per exploded view Fig 19 Some models will have this washer and spacer Installation 1 Place the new fan onto the motor shaft making sure that the spacer is still on the m...

Страница 4: ...asure across the brushes for the approximate dimension as shown in Fig 15 Made in U S A Carbon Brushes Amp Terminal Label Green Ground Wire Some Models Brush Screws Trough Brush Holder Tab Location 115 120 mm 4 5 4 7 Brush to Brush Dimension is Approximate Fig 15 Fig 14 Removal 1 Remove the dust cover by grasping the top near the On Off switch and pulling sharply out toward you 2 Remove the lower ...

Страница 5: ... CORD RETAINER DO NOT REUSE A CORD RETAINER 2 For switch replacement only insert the new ON OFF switch with the numbers 1 2 3 facing toward you into the dust compartment until secured by the retaining tabs Use a wire tie with the part number listed in the C Block parts list and place it in the location shown in Fig 10 taking care not to overtighten it Tuck the wire connectors back into the dust co...

Страница 6: ...A 18 Wheel AC9ØQNGZVØ6 2 A 19 Shaft Wheel AC16CNXZØØ 2 A 20 Screw Slider Support Pedal Spring AXTN4 16BFY 3 Shipped 10 per package A 21 Plastic Holder AMC78N VØØ 1 15 Removal 1 Remove the dust cover and switch cover to expose the electrical connections of the power cord ON OFF switch and wire cord 2 Pull the power cord into the dust compartment in order to remove the strain relief for power cord r...

Страница 7: ...e is removed DO NOT turn vacuum over as the motor may fall out Installation 1 Install the window and height adjust assembly in the new nozzle 2 Fit the nozzle from the motor shaft side first and rotate it into place on the dust container as illustrated Fig 8 3 Slide the plastic shaft through the nozzle housing and into the dust container Make sure that the slot on the bottom of the plastic shaft i...

Страница 8: ...Cord AC37GTEZØU 1 C 32 Wire Connector AMC 1CTCE23 3 Shipped 10 per package C 33 Handle AC95BTEZVU6 1 Includes Cord Storage Hook C 34 Lead Wire Assembly AC99WARGZØØ 1 C 35 Dust Cover AC6ØKBFCZUU1 1 C 36 Hose AC34PVØZUØ1 1 C 37 Plastic Cover Motor AC93FTEZØU 1 C 38 Wire Tie AMC596 7Ø2 1 Shipped 10 per package C 39 Protector AC69KJMZVØ6 1 C 40 Protector Spring Blue AC7ØKAHHZBØ 1 C 41 Protector Suppor...

Страница 9: ...sembly will have to be removed 1 Remove the lower plate as outlined in the LOWER PLATE REMOVAL INSTALLATION section 2 Carefully lift up on the agitator assembly until it clears both sides of the nozzle housing Fig 2 3 Remove the belt from the motor shaft by sliding it off between the end of the shaft and the nozzle housing Fig 3 NOTE The two 2 end caps may come off as you lift the agitator assembl...

Страница 10: ...nd caps Agitator Assembly Lower Plate Release latches and tilt off Belt Lift out with agitator Motor Dust Cover Pull off Lower Plate Release latches and tilt off Agitator Assembly Belt Lift out with end caps Nozzle Housing Pull off Motor Case Remove four screws and pull off On Off Switch Dust Cover Pull off Power Cord Switch Cover Remove two screws and pull off Nozzle Housing Lower Plate Release l...

Отзывы: