2. Unplug and remove damaged switch from the handle grip.
3.5.2. Installation
1. Connect the two lead wires on the new switch and place it
on the handle grip unit.
2. Insert the six (6) screws back.
NOTE: For general servicing, it is necessary to eliminate
pinching of any wire during reassembly. After servicing
any electrical component or electrical enclosure, the unit
should
be
reassembled
and
checked
for
dielectric
breakdown or current leakage.
3.6. Power Cord Replacement
3.6.1. Removal
1. Remove the switch cover and dust cover to expose the
electrical connections of the power cord.
2. Remove the strain relief (for power cord replacement) and
cut the wire connections.
3. Pull the power cord out of the dust compartment (for power
cord replacement).
3.6.2. Installation
1. Insert the new power cord (power cord replacement only)
into the dust compartment as far as necessary in order to
place a new cord retainer in proper location on power cord.
The proper location is approximately one and one eighth
inches / thirty millimeters (1 1/8” / 30 mm) of new power
cord outer jacket extending past the strain relief. Attach
wires with wire connectors according to the wiring diagram
in the front of this manual. ONLY USE A NEW STRAIN
RELIEF, DO NOT REUSE A STRAIN RELIEF.
2. Replace the switch cover, the four (4) switch cover screws,
and the dust cover. Care should be taken not to pinch wires
and make sure that the switch cover goes on easily and
stays flat. If there is resistance to the switch cover lying flat
and in place, stop, remove the cover and make sure that no
wires are being pinched. DO NOT USE A POWER
SCREWDRIVER TO SECURE THE COVER.
NOTE: For general servicing, it is necessary to eliminate
pinching of any wire during reassembly. After servicing
any electrical component or electrical enclosure, the unit
should
be
reassembled
and
checked
for
dielectric
breakdown or current leakage.
3.7. Handle Release Assembly
3.7.1. Removal
1. Turn the vacuum over and remove the lower plate, belt and
agitator as outlined in their respective removal sections.
2. Remove the switch cover and dust cover to freely lift the
nozzle housing and slide it out from the motor shaft.
13