3.9. MAINS LEAD
1. Remove hose end and front body as explained previously in
paragraph 3.8 MAIN FUSE.
2. Remove mains lead connections and take it out. (Fig. 20)
NOTE: To release the terminal from the housing, use a
tool Ref.: VLJ-20 Supplied by JST.
3. Replace mains lead with a new one, and connect it refer to
the schematic diagram and re-install it. (Fig.21)
NOTE:
Make
sure
the
lead
wires
are
correctly
positioned to avoid pinching them between parts.
4. Reassemble base suction inlet and remaining parts in the
reverse order.
3.10. ON/OFF SWlTCH
1. Remove hose end and front body as explained previously in
paragraph 3.8 MAIN FUSE.
2. Remove the lead wires (provided with quick-connect
terminal) from the switch tabs. (Fig.22)
3. Release switch claws with a flat-head screwdriver and take
it out. (Fig.23)
4. Replace ON/OFF Switch with a new one and re-install it.
5. Connect the lead wires refer to the schematic diagram and
reassemble base suction inlet and remaining parts in the
reverse order.
8