background image

2

1 Specifications

Model No.

MC-CG691

MC-CG691K

Power source

AC230V~50Hz

AC240V~50Hz

Input power (MAX)

1300W

Power control

O

Extension wand

Telescopic

Floor nozzle

O

Dimensions (W x L x H)

300

×

440

×

235

Cord length

5.0m

Net weight

5.0kg

Attachments (cleaning tools)

Crevice nozzle/Upholstery nozzle

Содержание MC-CG691-RA76

Страница 1: ...mponents 3 3 Troubleshooting Guide 4 4 Disassembly and Assembly Instructions 5 4 1 Dust box lid U removal 5 4 2 Separate the upper and lower body units 5 4 3 Separate the cord reel U and the body partition U 6 4 4 Printed Circuit Board PCB AU removal 7 4 5 Motor removal 8 5 Wiring Connection Diagram 9 6 Exploded View and Replacement Parts List 10 6 1 EXPLODED VIEW ATTACHMENTS 10 6 2 PARTS LIST ATT...

Страница 2: ...1K Power source AC230V 50Hz AC240V 50Hz Input power MAX 1300W Power control O Extension wand Telescopic Floor nozzle O Dimensions W x L x H 300 440 235 Cord length 5 0m Net weight 5 0kg Attachments cleaning tools Crevice nozzle Upholstery nozzle ...

Страница 3: ...3 2 Location of Controls and Components ...

Страница 4: ...ny abnormality replace the PCB AU Triac inside the printed circuit board AU Perform the following examination and check the triac If there is any abnormality replace the PCB AU Motor runs but there is no suction Paper dust bag dust box second ary filter Check if the paper dust bag or the dust box is full of waste Is there some blockage in the sec ondary filter If the paper dust bag is full replace...

Страница 5: ...ore for one second Dielectric strength Must withstand an AC voltage of 1 250 V applied across the power plug and the motor core for one minute Do not alter the model parts or materials during repair If a wiring unit is supplied as a repair part replace the whole unit with the new one instead of repairing or reconnecting the broken portions only Insert remove the fast on terminals by pushing pullin...

Страница 6: ...ls Pull the terminals out while holding down the termi nal lock release 3 Slowly remove the plug from the body cover partition stopper and release the pre winding spring 4 After inserting a screwdriver into the slit in the shaft and turning 90 degrees to the left pull the cord reel U away from the body partition U When assembling carry out pre winding for the spring The number of times to pre wind...

Страница 7: ...ort cover U 2 Remove the four screws affixing the motor support cover U 3 Remove the motor support cover U and remove the PCB AU 4 Disengage the fast on terminals of the two lead wires connecting the PCB AU Note When disengaging the fast on terminals pull straight out without lateral movement while holding down the lock release ...

Страница 8: ... front 3 Remove the motor support front from the motor unit 4 Remove the motor support rubber front from the motor unit 5 Remove the noise suppressor U from the motor unit 6 Remove the two lead wires from the motor unit Note Make sure that the thermal protector is on the under side when setting the assembled motor into the lower body ...

Отзывы: