background image

Configuration

Programming Guide

31

Parameter

Status Message

Default

Enable

Value Range

1.

Enable

2.

Disable

Description/Function

Specifies whether to send the Status Message to ISDN or not.

Reference

None

Parameter

Status Receive

Default

Disconnect

Value Range

1.

Disconnect

2.

Ignore

Description/Function

Specifies the treatment of the call when the Status Message 
provided by ISDN doesn't match the actual status of the call. 

Reference

None

Parameter

[Line Mode] L1 Mode

Default

(Display only)

Value Range

Permanent (fixed)

Description/Function

Displays the active mode of the Layer 1 on an ISDN line basis. 

Reference

None

Parameter

[Line Mode] L2 Mode

Default

(Display only)

Value Range

Permanent (fixed)

Description/Function

Displays the active mode of the Layer 2 on an ISDN line basis. 

Reference

None

Parameter

[Line Mode] Access Mode

Default

(Display only)

Value Range

P-MP (fixed)

Description/Function

Displays the configuration on an ISDN line basis. 

Reference

None

Содержание LX-TD500

Страница 1: ...uper Hybrid System and save this manual for future reference Thank you for purchasing the Panasonic Model KX TD500 Digital Super Hybrid System Model No KX TD500 Digital Super Hybrid System Programming Guide DIGITA L SUPER HYBR ID SYSTE M RUN OFF LINE ALARM ...

Страница 2: ...ructions for the end users using Proprietary Telephones PTs Single Line Telephones SLTs or DSS Consoles Installation Manual Describes information necessary for installing the hardware and system maintenance Note Throughout this manual the term he or she his or her may be used In order to improve readability rather than continually use he she we have only used one of these terms The term he or she ...

Страница 3: ...vice COS 103 2 5 System Timer 113 2 6 Local Hunt Sequence 123 2 7 Trunk to Trunk Restriction 124 2 8 System Option 125 2 9 PRI Originating Control 148 3 Group 151 3 1 Group 152 3 2 Trunk Group 153 3 3 Extension Group 166 3 4 Paging Group 179 3 5 Incoming Group 180 3 6 OGM Group 193 4 Line 197 4 1 Line 198 4 2 Trunk Line 199 4 3 Extension Line 211 4 4 DSS Console 231 4 5 Doorphone 240 4 6 External ...

Страница 4: ...lection 288 7 2 Time Table 289 7 3 Leading Digits Table 290 7 4 Routing Plan 292 7 5 Digits Modification Table 294 8 Private Network 297 8 1 Private Network 298 8 2 TIE Routing Table 299 9 DID Dial 301 9 1 DID Dial 302 9 2 DID Dial Registration 303 10 Maintenance 309 10 1 Maintenance 310 10 2 External Modem 1 2 311 10 3 External Modem 2 2 313 10 4 SMDR 314 10 5 Power Failure Transfer 320 10 6 Syst...

Страница 5: ...Configuration Programming Guide 5 Section 1 Configuration ...

Страница 6: ...Configuration 6 Programming Guide 1 1 Configuration Used to determine the basic system configuration ...

Страница 7: ...ERMT The contents of Card Properties screens vary from one type of optional card to another but similar optional cards have similar Card Properties screens Note You can get information on Card Properties parameters by opening Help menu on the Menu bar The following explanation is assumed that five DHLC cards are assigned to Slot No 1 to No 5 respectively by Slot Assignment Editing Card Properties ...

Страница 8: ...tional cards at a time This eliminates the needs to edit each Card Properties data one by one Up to 16 optional cards can be specified as the copy destination The following example shows how to copy the Card Properties data of a DHLC card assigned to Slot No 1 to other DHLC cards assigned to Slot No 2 to 5 Copying the Card Properties to Other Card Properties 1 Edit the Card Properties of the copy ...

Страница 9: ...ing Guide 9 3 Point to and click Card Properties Copy screen is displayed 4 Point to and click All displayed Slot Nos will be highlighted You can specify a certain Slot No individually by clicking it directly Properties Copy ...

Страница 10: ... shelves Section 1 2 Slot Assignment consists of the following sub sections 1 2 1 Slot Assignment 1 2 2 Card Properties HLC SLC OPX SLC M 1 2 3 Card Properties DHLC ESLC DLC 1 2 4 Card Properties LCOT GCOT 1 2 5 Card Properties ELCOT 1 2 6 Card Properties ELCOT Caller ID 1 2 7 Card Properties T1 1 2 8 Card Properties BRI 1 2 9 Card Properties BRI SPID DN 1 2 10 Card Properties PRI23 1 2 11 Card Pr...

Страница 11: ...Configuration Programming Guide 11 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration ...

Страница 12: ... Remote Circuit card ESLC Enlarged Single Line Telephone Circuit with Message Waiting card GCOT Ground Start Central Office Trunk card HLC Hybrid Line Circuit card LCOT Loop Start Central Office Trunk card OPX Off Premise Extension card PLC Proprietary Line Circuit card PRI23 ISDN Primary Rate Access Interface card RMT Remote Circuit card SLC Single Line Telephone Circuit card SLC M Single Line Te...

Страница 13: ...OUS 3 FAULT Description Function Used to set the status of the service cards 1 INS In Service The target service card is operating normally 2 OUS Out of Service Programming data for the target service card is entered but the target service card is not assigned to the system 3 FAULT The target service card is defective hardware In this case the LED indicator on the service card is lit Reference Non...

Страница 14: ...reby interrupting loop current Duration time required to detect the number of breaks may vary depending on the type of SLT connected Reference None Parameter Flash Detection Default Yes Value Range 1 Yes 2 No Description Function Activates or deactivates the detection of Flash signal transmitted from an SLT This determines the treatment of the call after an SLT user flashes the switchhook If set t...

Страница 15: ...eference None Parameter Flash Detection Default Yes Value Range 1 Yes 2 No Description Function Activates or deactivates the detection of Flash signal transmitted from an SLT This determines the treatment of the call after an SLT user flashes the switchhook If set to Yes the system will place the call on consultation hold Therefore flash detection is enabled If set to No the system will disconnect...

Страница 16: ...Specifies the length of time in milliseconds that the system recognizes as an off hook signal sent from the local Central Office Assignable for DHLC and ESLC only Reference None Parameter Flash Detection Timer Default 208 1016 ms Value Range 1 208 1016 ms 2 80 1016 ms Description Function Specifies the time range in milliseconds that the system requires to recognize a switchhook flash Assignable f...

Страница 17: ...e value depending on the requirements of your local Central Office Reference None Parameter Break Default 60 Value Range 1 60 2 67 Description Function Specifies the break for pulse digits This is the ratio between on hook and off hook signals during digit transmission Reference None Parameter Pulse Feedback Tone Default Yes Value Range 1 Yes 2 No Description Function On outgoing CO calls the dial...

Страница 18: ...digit Pause Default 830 ms Value Range 1 630 ms 2 830 ms 3 1030 ms Description Function Used to distinguish between pulse signals To meet the requirements of your Central Office select the appropriate value that represents the delay between dial pulses This setting is only required when using dial pulse trunks Reference None ...

Страница 19: ...7 Description Function Specifies the break for pulse digits This is the ratio between on hook and off hook signals during digit transmission Reference None Parameter Flash Time Default 608 ms Value Range 16 4080 ms in 16 ms increments Description Function Specifies the length of Flash signal which the system sends to the local Central Office Notes This assignment is helpful when you need finer res...

Страница 20: ...r ID screen Section 1 2 6 Card Properties ELCOT Caller ID by clicking on this screen Reference None Parameter Inter digit Pause Default 830 ms Value Range 1 630 ms 2 830 ms 3 1030 ms Description Function Used to distinguish between each pulse signal To meet the requirements of your Central Office select the appropriate value that represents the delay between dial pulses This setting is only requir...

Страница 21: ...ault 112 ms Value Range 64 304 ms in 16 ms increments Description Function Specifies DTMF Inter digit Pause Time Reference None Parameter Bell Disappearance Timer Default 5 s Value Range 1 15 s Description Function Specifies the length of time in seconds the system requires to confirm the disappearance of the bell signal from local Central Office Reference None Parameter Gain Adjustment Default 0 ...

Страница 22: ...n Activates or deactivates the detection of Caller ID signals transmitted from the Central Office on a port basis Reference 1 5 Attended Features F G Caller ID Service Parameter Detection Start Time Default 240 ms Value Range 80 1200 ms in 80 ms increments Description Function Specifies the time to begin detection of Caller ID signal after bell signal disappeared Reference 1 5 Attended Features F ...

Страница 23: ...length of time in milliseconds that the system requires to recognize the Caller ID signal sent from the Central Office Reference 1 5 Attended Features F G Caller ID Service Parameter Header Examination Default Enable Value Range 1 Enable 2 Disable Description Function Activates or deactivates the examination of header information of Caller ID signal Note This item must be Enable in case you use Ca...

Страница 24: ...e Parameter Line Coding Default B8ZS Value Range 1 B8ZS 2 AMI Description Function Specifies the T1 PCM Pulse Code Modulation Line Coding type for each T1 card Reference 1 3 System Features F G T1 Carrier Parameter Frame Sequence Default ESF Value Range 1 D4 2 ESF Description Function Specifies the Frame Sequence type for each T1 card Reference 1 3 System Features F G T1 Carrier ...

Страница 25: ...1 Carrier Parameter First Dial Timer CO Default 1 0 s Value Range 0 5 8 0 s in 0 5 s increments Description Function On outgoing CO calls the system waits at least 1 0 second after seizing the CO line before sending the dialing digits to the Central Office by default This allows the Central Office enough time to accept the dialing digits correctly Specifies the appropriate value depending on the r...

Страница 26: ...3 System Features F G T1 Carrier 1 5 Attended Features F G Direct Inward Dialing DID 3 1 TIE Line Features F G 4 2 Trunk Line P G Start Signal Type Parameter Break Default 60 Value Range 1 60 2 67 Description Function Specifies the break for pulse digits This is the ratio between on hook and off hook signals during digit transmission Reference 1 3 System Features F G T1 Carrier Parameter Pulse Fee...

Страница 27: ... Mode 3 Description Function Specifies the signaling bit to be monitored using the LED on the T1 card 1 Mode 1 LED SYNC ERROR RAI AIS SYNC TR A TR B TR C TR D bit 2 Mode 2 LED SYNC ERROR RAI AIS SYNC RX A RX B RX C RX D bit 3 Mode 3 LED SYNC ERROR RAI AIS SYNC TR A TR B RX A RX B bit Note This setting is valid when the LPR software version of the T1 card is Y311D or later Reference 4 7 Digital Tru...

Страница 28: ...1 Carrier Parameter Flash Detection Default No Value Range 1 Yes 2 No Description Function Activates or deactivates the detection of Flash signal transmitted from other PBX which is connected to this system via TIE Line If set to No the system does not recognize a switchhook flash Reference 1 3 System Features F G T1 Carrier Parameter Flash Detection Timer Default 208 1016 ms Value Range 1 208 101...

Страница 29: ... G T1 Carrier Parameter Break Detection Default 16 96 ms Value Range 1 16 96 ms 2 16 136 ms Description Function Specifies the break detection length Reference 1 3 System Features F G T1 Carrier Parameter Transmission of RAI Default No Value Range 1 Yes 2 No Description Function Specifies whether to send or not RAI Remote Alarm Indication signal to the Central Office Note This setting is valid whe...

Страница 30: ...Display only Value Range National ISDN1 fixed Description Function Displays the ISDN type Reference None Parameter DTMF Signal Duration Default 80 ms Value Range 1 80 ms 2 160 ms Description Function Specifies the duration of the DTMF signals sent to ISDN Reference None Parameter DTMF Signal Inter digit Pause Default 112 ms Value Range 64 240 ms in 16 ms increments Description Function Specifies D...

Страница 31: ...ISDN doesn t match the actual status of the call Reference None Parameter Line Mode L1 Mode Default Display only Value Range Permanent fixed Description Function Displays the active mode of the Layer 1 on an ISDN line basis Reference None Parameter Line Mode L2 Mode Default Display only Value Range Permanent fixed Description Function Displays the active mode of the Layer 2 on an ISDN line basis R...

Страница 32: ...ription Function Specifies whether the system supplies an electric power to TE or not Reference None Parameter Line Mode SPID DN Default Value Range Description Function You can enter into SPID DN screen Section 1 2 9 Card Properties BRI SPID DN by clicking on this screen Reference None Parameter Timer Setting Default Value Range Description Function You can enter into ISDN Protocol Timer screen S...

Страница 33: ...s and signals DN Directory Number Used to decide the ISDN BRI call destination Assign this number as DID MDN No in Section 9 2 1 DID Dial Registration Note When an extension user makes an outside call using an ISDN BRI line the number stored in DN Section 1 2 9 Card Properties BRI SPID DN is displayed on the telephone of the other party as the CLIP number Parameter Software Information Default Dis...

Страница 34: ...t Blank Value Range Up to 20 digits consisting of 0 9 or P Pause Description Function Specifies an SPID on an ISDN BRI port basis Reference None Parameter DN Default Blank Value Range Up to 20 digits consisting of 0 9 or P Pause Description Function Specifies a DN on an ISDN BRI port basis Reference 2 2 ISDN Originating Features F G Calling Line Identification Presentation CLIP 4 3 19 Calling Line...

Страница 35: ... Receive Default Disconnect Value Range 1 Disconnect 2 Ignore Description Function Specifies the treatment of the call when the Status Message provided by ISDN doesn t match the actual status of the call Reference None Parameter DTMF Signal Duration Default 80 ms Value Range 1 80 ms 2 160 ms Description Function Specifies the duration of the DTMF signals sent to ISDN Reference None Parameter DTMF ...

Страница 36: ... F72 SLC96 Description Function Specifies the Frame Sequence type for the PRI23 card Reference None Parameter Software Information Default Display only Value Range Description Function Displays the ROM version of the PRI23 card software and ROM checksum Reference 4 6 Digital Trunk Error Report I M 4 7 Digital Trunk Details I M 2 1 ISDN Features F G Integrated Services Digital Network ISDN Extensio...

Страница 37: ...I and PRI23 cards Parameter Timer Setting Default Value Range Description Function You can enter into ISDN Protocol Timer screen Section 1 2 11 Card Properties BRI PRI23 ISDN Protocol Timer by clicking on this screen Reference None Parameter T01 Default 60 s Value Range 0 300 s Description Function Trunk port Specifies the maximum time allowed to the system after receiving the notification of inco...

Страница 38: ...ter sending the request of call disconnection to ISDN before receiving the reply to it Reference None Parameter T04 Default 10 s Value Range 0 60 s Description Function Trunk port Specifies the time to delay the announcement of call disconnection This setting is used when an announcement is given to the system from ISDN before disconnecting the call Reference None Parameter T05 Default 60 s Value ...

Страница 39: ...e maximum time allowed to the system after receiving the request of call disconnection from ISDN before replying to it Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T200 Default 1 s Value Range 1 5 s Description Function Specifies the maximum time that the system waits after sending the L2 command to ISDN before receiving the reply to it Reference None Parameter CO Qsig Mast...

Страница 40: ...e that the system waits after sending the SETUP call setting message to ISDN before receiving the reply to it Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T304 Default 0 s BRI 30 s PRI23 Value Range 0 255 s Description Function Specifies the maximum time allowed between each digit on an outgoing call Applies to the overlap receiving Reference None Parameter CO Qsig Master P...

Страница 41: ...the continuance message Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T3D3 Default 10 s BRI 30 s PRI23 Value Range 1 120 s Description Function Specifies the time that the system tries to establish L2 in Permanent mode Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T3D9 Default 20 s Value Range 0 255 s Description Function Specifies the time that the sy...

Страница 42: ...en each digit on an incoming call Applies to the overlap receiving Reference None Parameter Extension T303 Default 5 s BRI 2 s PRI23 Value Range 2 12 s Description Function Specifies the maximum time that the system waits after sending the SETUP call setting message to ISDN before receiving the reply to it Reference None Parameter Extension T304 Default 0 s Value Range 0 255 s Description Function...

Страница 43: ...tem waits after sending the DISC disconnection message to ISDN before receiving the reply to it This setting is used when inband tone is supplied Reference None Parameter Extension T310 Default 10 s BRI 40 s PRI23 Value Range 10 300 s Description Function Specifies the maximum time that the system waits after receiving the CALL PROCEEDING call setting acceptance message before receiving the contin...

Страница 44: ...es the time that the system tries to disconnect L2 in Call by Call mode Reference None Parameter CYCLIC Tone Detection Mode Default Standard Value Range 1 Standard 2 Option Description Function Specifies the CYCLIC Tone Detection Mode as Standard or Option 1 Standard Fixed Detection Mode 2 Option Flexible Detection Mode Note Option is available when the LPR software version is greater than 1 Refer...

Страница 45: ...es the minimum time in milliseconds that the CYCLIC tone from the Central Office must be sent When the system detects the tone within the time range it is recognized as Tone ON Note This parameter is valid when Option is selected in the CYCLIC Detection Mode menu Reference None Parameter Tone ON Time Max Default 244 8 ms Value Range 57 6 3600 ms in 14 4 ms increments Description Function Specifies...

Страница 46: ...cted in the CYCLIC Detection Mode menu Reference None Parameter Tone OFF Time Max Default 244 8 ms Value Range 57 6 3600 ms in 14 4 ms increments Description Function Specifies the maximum time in milliseconds that the CYCLIC tone from the Central Office is not detected When the system detects no tone within the time range it is recognized as Tone OFF Note This parameter is valid when Option is se...

Страница 47: ... and the Area Code Parameter Baud Rate Modem Speed Default 33600 bps Value Range 1 1200 bps 2 9600 bps 3 14400 bps 4 19200 bps 5 28800 bps 6 33600 bps Description Function Specifies the maximum data transmission speed between the ERMT card and the modem which is connected to a Personal Computer Maintenance Device Reference 3 4 3 Remote Administration Remote Connection I M ...

Страница 48: ... Software Version Default Display only Value Range Description Function Displays the System ROM version Reference None Parameter Area Code Default Display only Value Range 0 31 Description Function Indicates the jumper setting on the CPU card thereby revealing what area country the system is intended for Reference None ...

Страница 49: ...atus Digital OHCA Card Default Display only Value Range 1 Not Installed 2 Installed Description Function Displays whether an optional Digital OHCA Card is installed or not Reference 1 3 System Features F G Integration DPT 1 6 Originating Features F G Off Hook Call Announcement OHCA Off Hook Call Announcement OHCA Whisper Parameter System Clock Status Default Display only Value Range 1 Internal 2 E...

Страница 50: ...rovided by the Digital Network Note External should be selected when the system is connected to the Digital Network Reference 1 3 System Features F G T1 Carrier 2 1 ISDN Features F G Integrated Services Digital Network ISDN Parameter Clock Configuration Master Card No Default Display only Value Range 101 314 T1 BRI PRI23 Description Function Displays the physical number of the T1 BRI PRI23 card wh...

Страница 51: ...cal number of the T1 BRI PRI23 card that provides External Clock pulse to the system in priority order Note You have to assign this parameter even if only one T1 BRI PRI23 card is installed When more than one T1 BRI PRI23 card is installed in the system each of them should be registered Reference 1 3 System Features F G T1 Carrier 2 1 ISDN Features F G Integrated Services Digital Network ISDN ...

Страница 52: ... physical number of the trunk card and its type which you are going to program Reference 1 2 Slot Assignment P G Parameter Group No Default DID card 47 Others 1 Value Range 1 48 Description Function Specifies the trunk group 1 48 to which the trunk port is assigned Note Each trunk port must be assigned to a Trunk Group This program defines the Trunk Group assignment for each trunk port Reference 1...

Страница 53: ...er Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the trunk port 1 INS The trunk port is In Service 2 OUS The trunk port is Out of Service 3 FAULT The trunk port is defective Reference None ...

Страница 54: ...extension ports XDP extensions are on ports 9 through 16 of a DHLC card Parameter Card No Default Value Range XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the physical number of the extension card and its type which you are going to program Reference 1 2 Slot Assignment P G ...

Страница 55: ...nected to the extension port Notes DPT integration except TVS300 does not function unless the VPS is connected to a DLC or DHLC card whose LPR Version ROM Version is 1 or later DPT integration TVS300 only does not function unless it is connected to a DLC or DHLC card whose LPR Version ROM Version is 2 or later You can confirm the LPR Version ROM Version of the DLC and the DHLC card in Card Propert...

Страница 56: ...SP PHONE 1 Line Display 12 CO T7350 APT with MONITOR 12 CO T7220 DPT with SP PHONE 24 CO T7230 DPT with SP PHONE 2 Line Display 24 CO T7235 DPT with SP PHONE 6 Line Display 12 CO T7250 DPT with MONITOR 6 CO T7420 DPT with SP PHONE 12 CO T7425 DPT with SP PHONE 24 CO T7431 DPT with SP PHONE 1 Line Display 12 CO T7433 DPT with SP PHONE 3 Line Display 24 CO T7436 DPT with SP PHONE 6 Line Display 24 C...

Страница 57: ...1 128 Description Function Specifies the Extension Group 1 128 to which the extension port is assigned Note Group No of the first extension is assigned to 128 Reference 1 3 System Features F G Extension Group 3 3 Extension Group P G Parameter Parallel XDP DHLC card Default Parallel Value Range 1 Parallel 2 XDP Description Function Specifies whether to enable or disable Paralleled Connection of PT ...

Страница 58: ...led Telephone Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the extension port 1 INS The extension port is In Service 2 OUS The extension port is Out of Service 3 FAULT The extension port is defective Reference None Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned t...

Страница 59: ...ation of Card Properties and confirm that the software version of the card shows more than 1 When you connect the TVS to the existing DLC DHLC Go to step 2 2 Assignment of the port which will be connected to the VPS System Change the attribute of the port to be connected to the TVS to VPS DPT in 1 3 Extension Port Assignment screen When the attribute of the port is changed to VPS DPT the parameter...

Страница 60: ...l turn on after the synchronization is completed It takes for about 30 seconds to 1 minute to be able to use the VPS system It depends on the VPS model and the port number you set up Parameter TVS No Default 1 Value Range 1 8 Description Function Specifies one of the Panasonic Voice Processing Systems VPSs connected to the KX TD500 system which you are going to program Reference 1 3 System Feature...

Страница 61: ...Default Display only Value Range Description Function Displays the Jack No of VPS Reference 1 3 System Features F G Integration VPS Parameter Port No Default Blank Value Range 1 16 DLC card or 1 8 DHLC card Description Function Specifies the extension port to which the VPS DPT jack is to be connected Notes This program tells the system which extension port is connected to the Panasonic Voice Proce...

Страница 62: ...ion numbers to each port To reach the Voice Mail system users dial these extension numbers When you swap DN you already programmed among Jacks you must clear these DNs once Reference 2 3 Numbering Plan P G Parameter Ext No 1 Group No Default Blank Value Range 1 128 Description Function Specifies the Extension Group 1 128 to which the B1 channel of the VPS DPT port is assigned Note Specifies the ex...

Страница 63: ...rammed among Jacks you must clear these DNs once Reference 2 3 Numbering Plan P G Parameter Ext No 2 Group No Default Blank Value Range 1 128 Description Function Specifies the Extension Group 1 128 to which the B2 channel of the VPS DPT port is assigned Note Specifies the extension group 1 128 to which the type of extension group VM or AA is assigned Reference 1 3 System Features F G Extension Gr...

Страница 64: ...Configuration 64 Programming Guide Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None ...

Страница 65: ...Assign the directory number and the extension group number when the channel type is assigned to OPX Note The channel type should be assigned on the basis of the contract with a telephone exchange 4 When the channel type of the port is assigned to a trunk line LCO GCO DID or TIE E M assign the parameters of the port like usual trunk line in 4 1 Trunk Line screen When the channel type is assigned to...

Страница 66: ...4 DID 5 TIE E M 6 OPX Description Function Specifies the type of T1 interface per channel 1 Undefined Not assigned 2 LCO Loop Start Central Office 3 GCO Ground Start Central Office 4 DID Direct Inward Dialing 5 TIE E M TIE Line 6 OPX Off Premise Extension Reference 1 3 System Features F G T1 Carrier Parameter DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies ...

Страница 67: ...sion Group Trunk Group 3 2 Trunk Group P G 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the T1 port 1 INS The T1 port is In Service 2 OUS The T1 port is Out of Service 3 FAULT The T1 port is defective hardware In this case the LED indicator on the T1 card will light Reference None Parameter DN Refer Default ...

Страница 68: ...Value Range 101 314 Description Function Displays the slot number of the DISA card which you are going to program Reference 1 2 Slot Assignment P G Parameter Card No 1 8 OGM Group No Default 1 Value Range 1 8 Description Function Specifies the OGM Group 1 8 to which the DISA card is assigned Reference 1 3 System Features F G Outgoing Message OGM 3 6 OGM Group P G ...

Страница 69: ...sed to assign the parameters for BRI Basic Rate Interface ports Parameter Card No Default Value Range XXX BRI XXX Card No 101 314 Description Function Specifies the physical number of the BRI card which you are going to program Reference 1 2 Slot Assignment P G ...

Страница 70: ...ice Reference 2 1 ISDN Features F G Integrated Services Digital Network ISDN Integrated Services Digital Network ISDN Extension 4 7 ISDN Extension Line P G Parameter DN Default Blank Value Range 3 4 digits consisting of 0 9 or X Description Function Specifies the DN Directory Number for the BRI port Assignable only when EXT is specified in Type assignment Note X can be used as a wild card characte...

Страница 71: ...up 3 2 Trunk Group P G 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the BRI port 1 INS The BRI port is In Service 2 OUS The BRI port is Out of Service 3 FAULT The BRI port is defective hardware In this case the LED indicator on the BRI card will light Reference None Parameter DN Refer Default Value Range Des...

Страница 72: ...d to assign the parameters for PRI Prime Rate Interface ports Parameter Card No Default Value Range XXX PRI23 XXX Card No 101 314 Description Function Specifies the physical number of the PRI23 card which you are going to program Reference 1 2 Slot Assignment P G ...

Страница 73: ... assigned to 1 First assign the type and then Group No Reference 2 1 ISDN Features F G Integrated Services Digital Network ISDN Integrated Services Digital Network ISDN Extension 3 1 TIE Line Features F G TIE Line Service 4 7 ISDN Extension Line P G Parameter DN Default Blank Value Range 3 4 digits consisting of 0 9 or X Description Function Specifies the DN Directory Number for the PRI port Assig...

Страница 74: ... is assigned Reference 1 3 System Features F G Extension Group Trunk Group 3 1 TIE Line Features F G TIE Line Service 3 2 Trunk Group P G 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the PRI port 1 INS The PRI port is In Service 2 OUS The PRI port is Out of Service 3 FAULT The PRI port is defective hardware ...

Страница 75: ...System Programming Guide 75 Section 2 System ...

Страница 76: ...System 76 Programming Guide 2 1 System Used to assign parameters which affect system wide operation ...

Страница 77: ...o program Reference 1 3 System Features F G Tenant Service Parameter Operator FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number of Extension Group or Incoming Group Calls by the feature number for Operator Call will reach to this destination Reference 1 3 System Features F G Floating Station 1 6 Originating Features F G Oper...

Страница 78: ... Reminder Remote Wake Up Call U M 4 3 74 Timed Reminder Wake Up Call U M Parameter DAY NIGHT Switching Mode Default Manual Value Range 1 Manual 2 Auto Description Function Specifies the Day Night Lunch Break switching mode Manual or Auto 1 Manual The extension allowed by COS Class of Service programming the Manager or the Operators can switch Day Night Lunch Break mode at any time desired by diali...

Страница 79: ...t numbers to which extensions in this tenant can make a call If no tenant numbers are checked in this field extension users within this tenant cannot make a call to extensions in other tenants Making calls from one tenant to another is not allowed by default Reference 1 3 System Features F G Tenant Service Parameter Day SUN SAT Default 9 00 AM Value Range 1 Disable 2 12 00 11 59 PM AM Description ...

Страница 80: ...s Day Description Function Specifies the end time for Lunch Service Reference 1 3 System Features F G Night Service Parameter Break Start SUN SAT Default 3 00 PM Value Range Same as Day Description Function Specifies the start time for Break Service Reference 1 3 System Features F G Night Service Parameter Break End SUN SAT Default 3 30 PM Value Range Same as Day Description Function Specifies the...

Страница 81: ... External Music Source I M Parameter BGM Source Default MUS1 Value Range 1 None 2 MUS1 3 MUS2 Description Function Specifies the Music Source port to be used for BGM Reference 2 8 2 External Music Source I M Parameter Manager Extension DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension for the Manager Reference 1 3 System Features F G Manager Ext...

Страница 82: ... Selection Default No check Value Range 1 Check Enable 2 No check Disable Description Function Specifies whether to utilize ARS Automatic Route Selection or not If set to No No check Trunk Access Idle is activated instead of ARS when an extension user dials 9 for making an outside call Reference 1 6 Originating Features F G Automatic Route Selection ARS 7 1 ARS Automatic Route Selection P G Parame...

Страница 83: ...in the tenant can make System Speed Dialing calls without toll restriction Reference 1 6 Originating Features F G Toll Restriction Override for System Speed Dialing Parameter Confirmation Tone for Station or External Paging Default Check Value Range 1 Check Enable 2 No check Disable Description Function If checked a confirmation tone is sent to the extension user who initiated the Station Paging o...

Страница 84: ... Value Range 1 2 digits consisting of 0 9 Description Function Specifies the leading 1 or 2 digits of the extension number Any number 0 through 9 can be set Notes If one digit is assigned as the leading digit 3 digit extension numbers can be assigned If two digits are assigned as the leading digits 4 digit extension numbers can be assigned Reference 1 3 System Features F G Flexible Numbering ...

Страница 85: ... Flexible Numbering Parameter 4 4th Hundred Block Extension Default 13 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference 1 3 System Features F G Flexible Numbering Parameter 5 5th Hundred Block Extension Default 14 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference 1 3 System Features F G Flexible Numbering ...

Страница 86: ...nsisting of 0 9 Description Function Same as the Parameter 1 Reference 1 3 System Features F G Flexible Numbering Parameter 9 9th Hundred Block Extension Default 23 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference 1 3 System Features F G Flexible Numbering Parameter 10 10th Hundred Block Extension Default 24 Value Range 1 2 digits consisting of 0 9 De...

Страница 87: ...N for each Operator Group can also be used for this purpose Reference 4 3 53 Operator Call U M Parameter 18 Local CO Line Access ARS Default 9 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for making an outside call by ARS Automatic Route Selection or Trunk Access Idle Reference 4 3 54 Outward Dialing Trunk Access U M Parameter 19 Trunk Group Access ...

Страница 88: ...aling U M Parameter 22 Speed Dialing Station Programming Default 30 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for programming Station Speed Dialing numbers at each extension Reference 4 3 72 Station Speed Dialing U M Parameter 23 Doorphone Call Default 31 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature numbe...

Страница 89: ...nsisting of 0 9 or Description Function Specifies the feature number for making a paging announcement through the built in speakers of PTs Reference 4 3 55 Paging U M Parameter 27 Station Paging Answer Default 43 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for answering the paging announcement through the built in speakers of PTs Reference 4 3 56 P...

Страница 90: ...3 13 Call Pickup U M Parameter 31 Hold Default 50 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for putting a call on hold and retrieving the call Reference 4 3 11 Call Hold U M Parameter 32 Hold Retrieve Station Default 51 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for retrieving a call held at anot...

Страница 91: ...Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for entering account codes which may be forced or optional depending on Class of Service programming Reference 4 3 2 Account Code Entry U M Parameter 37 Door Open Default 55 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for unlocking the Door Opener Referenc...

Страница 92: ... used to call back the party who left a Message Waiting indication Reference 4 3 46 Message Waiting U M Parameter 41 OGM Playback Record Default 36 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for recording playing back an OGM Outgoing Message For Manager Operator only Reference 4 4 6 Outgoing Message OGM Record Playback U M Parameter 42 Call FWD Do...

Страница 93: ... Call Waiting Set Cancel Default 731 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Call Waiting feature Reference 4 3 17 Call Waiting U M Parameter 46 Executive Busy Override Deny Set Cancel Default 733 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Executive B...

Страница 94: ...l U M Parameter 50 Station Lock Set Cancel Default 762 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Electronic Station Lockout feature Reference 4 3 30 Electronic Station Lockout U M Parameter 51 Night Mode Set Cancel Default 78 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for tu...

Страница 95: ... 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for turning on off the Call Log Incoming Overwrite Mode If turned on e g 561 overwriting the buffer will occur If turned off e g 560 new data will be disregarded when the buffer is full Reference 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Parameter 56 Call Log Incoming Log Lock Default 57 V...

Страница 96: ... of 0 9 or Description Function Specifies the feature number for Log in Log out to from the members of an Extension Group and Phantom Extensions Reference 4 3 45 Log In Log Out U M Parameter 59 Automatic Callback Busy Cancel Default 46 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for canceling Automatic Callback Busy feature Reference 4 3 6 Automati...

Страница 97: ...ameter 63 70 Quick dial 1 Quick dial 8 Default Blank Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for Quick dial features Reference 4 3 65 Quick Dialing U M Parameter 71 Reserved Reserved for future use Default Blank Value Range Description Function Reference Parameter 72 Remote DND Default 722 Value Range 1 4 digits consisting of 0 9 or Description...

Страница 98: ...4 digits consisting of 0 9 or Description Function Specifies the feature number for Trunk Route Control For Manager Operator only Reference 4 4 13 Trunk Route Control U M Parameter 75 UCD Monitor Mode Default 725 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for UCD Monitor mode One supervisor can be assigned per UCD Group The supervisor can monitor ...

Страница 99: ...l Default 721 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Paging Deny feature Reference 4 3 57 Paging Deny U M Parameter 94 Trunk Busy out Default 726 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for Trunk Busy out feature For Manager Operator only Reference 4 4 12 Trunk Busy Ou...

Страница 100: ...ture number for turning on off the CLIR Calling Line Identification Restriction and CNIR Calling Name Identification Restriction feature Reference 4 3 20 Calling Line Identification Restriction CLIR Calling Name Identification Restriction CNIR U M Parameter 98 Reserved Reserved for future use Default Blank Value Range Description Function Reference Parameter 99 Dial Information CTI Default Blank V...

Страница 101: ...e use Default Blank Value Range Description Function Reference Parameter 103 Group Login Logout Default 48 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for Group Log in Log out to from the members of an Incoming Group Reference 4 3 45 Log In Log Out U M Parameter 104 Group FWD Default 714 Value Range 1 4 digits consisting of 0 9 or Description Funct...

Страница 102: ...System 102 Programming Guide Parameter 105 120 Reserved Reserved for future use Default Blank Value Range Description Function Reference ...

Страница 103: ... Default 1 Value Range 1 96 Description Function Specifies the COS 1 96 which you are going to program Reference 1 3 System Features F G Class of Service COS 4 3 Extension Line P G Parameter Trunk Group Setting Default Value Range Description Function You can enter into Trunk Group Setting screen Section 2 4 2 by clicking on this screen Reference None ...

Страница 104: ...Optional Option mode An extension user can enter any account code if needed 2 Verify Toll Verified Toll Restriction Override mode An extension user can enter a pre assigned account code to override toll restriction 3 Verify All Verified All Calls mode An extension user must always enter a pre assigned account code when making any of the following outside calls unless it has previously been stored ...

Страница 105: ...7 extension users can call the extensions with this COS level Reference 1 6 Originating Features F G Toll Restriction Parameter Time Limit of Outside Calls Default No Value Range 1 Yes 2 No Description Function Specifies whether to restrict the duration of outside calls or not Notes If set to Yes the system disconnects a CO call originated or answered by the programmed extension user when the time...

Страница 106: ...ameter Off Hook Call Announcement OHCA Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether to utilize OHCA Whisper OHCA feature or not Note This setting is valid at the following PT extensions OHCA When the called extension is using the KX T7130 KX T7235 or KX T7436 Whisper OHCA When both calling and called extensions are using one of the KX T7400 series PTs Refere...

Страница 107: ...rence 4 3 33 Executive Busy Override U M Parameter DND Override Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables DND Override feature Reference 4 3 28 Do Not Disturb DND Override U M Parameter Busy Override Deny Default Enable Value Range 1 Enable 2 Disable Description Function Enables or disables Executive Busy Override Deny feature Note Executive Busy Overr...

Страница 108: ...r extension users such as Operators who handle a large volume of calls Reference 1 3 System Features F G Released Link Operation 4 3 67 Released Link Operation U M Parameter Digits Restriction in CO Talk Mode Default Unrestricted Value Range 1 Unrestricted 2 1 15 the digits to be dialed out Description Function Specifies the maximum number of digits that can be dialed during a CO call If the outsi...

Страница 109: ...on Function This setting is applied when an extension user makes an outside call using an SDN button on his own extension Assignable for a DN type PT extension only 1 Own Extension COS TRS level of his own extension is applied to the call when making an outside call using the SDN button 2 PDN COS TRS level of the owner extension is applied to the call when making an outside call using the SDN butt...

Страница 110: ...isplay by clicking on Class of Service screen Parameter Trunk Group No 01 48 Day Night Default All Check Value Range 1 No check Restricted 2 Check Not restricted Description Function Specifies the trunk group 01 48 which the extension user can use for making an outside call in Day Night mode respectively on a COS basis Reference 1 3 System Features F G Trunk Group 3 2 Trunk Group P G ...

Страница 111: ... or disables Secret Busy Override feature Reference 1 6 Originating Features F G Secret Busy Override 4 3 69 Secret Busy Override U M Parameter Transferring CO dial tone exempted from TRS Default Enable Value Range 1 Enable 2 Disable Description Function Allows you to transfer a CO dial tone to another extension so that it can make an outgoing call without TRS Reference 1 6 Originating Features F ...

Страница 112: ...is setting can set Call Forwarding feature to an Incoming Group so that all calls to the Incoming Group can be forwarded to specified Incoming Group or Extension Group 1 Disable Disables this feature 2 Own Group s Enables forwarding all calls to other Incoming Groups or Extension Groups Only its own group s can be set as the Call Forwarding setting extension 3 Any Group Enables forwarding all call...

Страница 113: ...ption Function Specifies the length of time in seconds that the system is to wait before alerting the extension user who held the call by Held Call Reminder ringing The reminder tone is emitted every 5 seconds until the held call is retrieved or until the caller hangs up Note If 0 is specified Hold Recall does not occur Reference 1 13 Audible Tone Features F G Hold Recall ...

Страница 114: ...ion 2 8 System Option Note If 0 is specified Transfer Recall does not occur Reference None Parameter Pickup Dial Waiting Time Default 1 s Value Range 0 5 s Description Function Specifies the length of time in seconds that the system is to wait after an extension user goes off hook for making a call before the system automatically dials the pre assigned telephone number for Pickup Dialing Note This...

Страница 115: ... PT Reference 1 3 System Features F G Station Message Detail Recording SMDR Parameter First Digit Time Default 10 s Value Range 5 120 s Description Function Specifies the maximum time allowed between the start of an outside dial tone and the first digit dialed on an outgoing call Reference None Parameter Inter digit Time Default 5 s Value Range 1 30 s Description Function Specifies the maximum tim...

Страница 116: ... before this timer expires the call will be disconnected Reference 1 11 Transferring Features F G Call Forwarding 4 3 9 Call Forwarding U M 4 3 Extension Line P G Parameter Extension to CO Line Call Duration Time Default 10 min Value Range 1 64 min Description Function Specifies the maximum time allowed for a call with an outside party This time limit can apply to outgoing CO calls only or both ou...

Страница 117: ... to CO line call If this timer expires during a CO to CO line call it will be disconnected Reference 1 5 Attended Features F G Direct Inward System Access DISA 1 11 Transferring Features F G Call Forwarding Call Transfer Parameter Door Opener Time Default 5 s Value Range 0 10 s Description Function Specifies the door opening duration Reference 1 3 System Features F G Door Opener 4 3 29 Doorphone C...

Страница 118: ...ng Time Default 30 s Value Range 30 240 s Description Function Specifies the length of ringing time in seconds of the Timed Reminder alarm Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 4 3 74 Timed Reminder Wake Up Call U M 4 4 11 Timed Reminder Remote Wake Up Call U M ...

Страница 119: ...ll after it was received by the system Reference 3 1 TIE Line Features F G TIE Line Service Parameter DISA Prolong Time Default 3 min Value Range 0 7 min Description Function A CO to CO line call duration is initially limited by CO to CO Line Call Duration Time However prolonging the CO to CO line call duration is possible To prolong the call duration the caller should press any dialpad key except...

Страница 120: ...ction Specifies the number of times 1 5 Timed Reminder Remote Timed Reminder Wake Up Call is repeated until the destination extension answers it Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 4 3 74 Timed Reminder Wake Up Call U M 4 4 11 Timed Reminder Remote Wake Up Call U M Parameter DISA Automated Attendant Time Default 1 s Value Range 1 5 s De...

Страница 121: ...nabled Call Forwarding No Answer Reference 1 5 Attended Features F G Direct Inward System Access DISA Parameter Intercept Timer after OGM Default 5 s Value Range 1 0 s Immediately 2 5 s 5 s later Description Function Specifies the length of time in seconds the system is to wait after sending OGM before directing the call to the IRNA destination Reference 1 5 Attended Features F G Direct Inward Sys...

Страница 122: ...Default Day 12 rings Night Lunch Break 0 ring Value Range Day 1 48 rings Night Lunch Break 0 48 rings Description Function Specifies the number of rings the system is to wait before activating IRNA Intercept Routing No Answer feature If an incoming CO call directed to a single extension is not answered within this timer IRNA redirects the call to another pre programmed destination Notes Call Forwa...

Страница 123: ...ault 01 1 Others None Value Range None 1 48 Description Function Specifies the trunk group 1 48 in hunting order Notes Local Hunt Sequence works only when ARS Automatic Route Selection mode is turned off The sequence can be used by any extension user in the system regardless of the tenant but trunk groups will be skipped if they do not belong to the same tenant as the extension user Reference 1 6 ...

Страница 124: ...p No Default 1 Value Range 1 48 Description Function Specifies the source trunk group 1 48 the first point of trunk to trunk relay which you are going to program Reference 3 1 TIE Line Features F G TIE Line Service Parameter Destination Trunk Group No 1 48 Default No check Value Range 1 No check Restricted 2 Check Not restricted Description Function Specifies the destination trunk group 1 48 the s...

Страница 125: ...ransfer Default Music on Hold Value Range 1 Ringback Tone 2 Music on Hold Description Function Used to determine whether the system sends Music on Hold or Ringback Tone to the party being transferred Ringback Tone is available when Music on Hold is not provided by the system Reference 1 11 Transferring Features F G Call Transfer 4 3 16 Call Transfer U M ...

Страница 126: ...ange 1 Release the trunk 2 Don t release the trunk Description Function Specifies the result of pressing the FLASH button on PT during an outside call Reference 1 12 Conversation Features F G External Feature Access Parameter 4 FLASH button operation when Don t release the trunk is selected at 3 Default Disconnect and hear CO dial tone Value Range 1 Disconnect and hear CO dial tone 2 Sending EFA s...

Страница 127: ...d outgoing calls Note This setting applies to the extension on which Time Limit of Outside Calls is enabled by COS programming Reference 1 3 System Features F G Limited Call Duration Parameter 6 Transfer recall destination Default Originating extension Value Range 1 Originating extension 2 Operator Description Function Specifies whether Transfer Recall occurs at the transfer originating extension ...

Страница 128: ...ce and Privacy Release Default Enable Value Range 1 Enable 2 Disable Description Function Allows you to remove Confirmation Tone 4 This tone is sent when a three party conference is established finished Reference 1 13 Audible Tone Features F G Confirmation Tones Parameter 9 Confirmation tone for Call Pickup Paging Paging Answer TAFAS Answer Hold Retrieve and Call Park Retrieve Default Enable Value...

Страница 129: ...Specifies the initial display of a display DPT such as KX T7235 KX T7436 in Station Speed Dialing Reference 4 5 8 KX T7235 Display Features Call Directory U M 4 5 10 KX T7431 KX T7433 KX T7436 Display Features U M Parameter 11 Sending pulse signal during CO call Default Enable Value Range 1 Enable 2 Disable Description Function Enables or disables sending pulse dialing signals during an outside ca...

Страница 130: ...A caller can prolong the duration of DISA CO to CO line call Reference 1 5 Attended Features F G Direct Inward System Access DISA Parameter 14 Dialing in DISA CO to CO talking Default Disconnect and make a new call Value Range 1 Disconnect and make a new call 2 Send out Dial Description Function The key can be entered during a DISA CO to CO line call The action taken by the system depends upon thi...

Страница 131: ...Call Waiting Data Line Security Do Not Disturb DND Electronic Station Lockout Executive Busy Override Deny Paging Deny Pickup Dialing Timed Reminder Also enabled is Dial Tone 4 indicates that messages are waiting Note Dial Tone 3 is not affected by this setting Reference 4 Tones Ring Tones F G 6 1 3 Tone List U M Parameter 17 Destination Busy DISA Default Send busy tone Value Range 1 Send busy ton...

Страница 132: ...nge 1 Send busy tone 2 Transferred to IRNA destination Description Function Specifies the treatment of TIE callers when they dial a busy extension Reference 3 1 TIE Line Features F G TIE Line Service Parameter 20 Off hook Monitor Default Enable Value Range 1 Enable 2 Disable Description Function Enables or disables Off hook Monitor feature on a system wide basis This feature allows a PT user on a ...

Страница 133: ...System Programming Guide 133 2 8 3 System Option 3 Used to assign system option parameters No 21 No 30 ...

Страница 134: ...e available message waiting lamp patterns are as follows s ON OFF Pattern 01 Pattern 02 Pattern 03 Pattern 04 Pattern 05 Pattern 06 512 ms 256 ms 256 ms s ON OFF s ON OFF 256 ms s ON OFF s ON OFF s ON OFF 1 28 1 28 1 28 1 28 5 12 5 12 5 12 2 56 2 56 10 512 ms 768 ms ...

Страница 135: ...age Waiting lamp patterns 2 2 s ON OFF Pattern 07 Pattern 08 Pattern 09 Pattern 10 Pattern 11 Pattern 12 s ON OFF s ON OFF 256 ms s ON OFF s ON OFF s ON OFF t 1 28 256 ms 1 28 1 28 1 28 t t 1 28 t 768 ms 20 10 20 10 10 20 10 10 20 5 12 ...

Страница 136: ...of the invalid DID calls Reference 1 5 Attended Features F G Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter 23 Illegal Number TIE Default Send reorder tone Value Range 1 Send reorder tone 2 Transferred to IRNA destination Description Function Specifies the treatment of the invalid TIE calls Reference 3 1 TIE Line Features F G TIE Line Service Parameter...

Страница 137: ...ration in talking Default Disconnect Value Range 1 Disconnect 2 Hold Description Function If set to Hold the PT user engaged in a call can with a single operation press a CO DN Answer key hold the current call and then either get another line or answer another call Reference 1 10 Holding Features F G Automatic Hold For Hold Parameter 27 Message Waiting lamp pattern Default 11 Value Range 01 12 Des...

Страница 138: ...alue Range 1 Mu Law 2 A Law Description Function Specifies the PCM Pulse Code Modulation conversion mode of KX T96xxx series trunk and extension cards Note This setting is required only when XMX for Mexico type KX T96xxx series trunk and extension cards are installed in the system In this case select A Law Reference None Parameter 30 Net CODEC Default Mu Law Value Range 1 Mu Law 2 A Law Descriptio...

Страница 139: ... a call waiting call simply by flashing the switchhook Reference 1 9 Answering Features F G Call Waiting Parameter 32 Whisper OHCA to extensions other than T74XX Default Disable Value Range 1 Enable 2 Disable Description Function If enabled an extension user can make a Whisper OHCA call to extensions other than KX T7400 series PTs Reference 1 6 Originating Features F G Off Hook Call Announcement O...

Страница 140: ...1 ON 2 OFF Description Function When a CO line is busied out manually by the Manager an Operator the status of Loop Relay is controlled by this setting Reference 1 3 System Features F G Trunk Busy Out 4 4 12 Trunk Busy Out Setting U M Parameter 35 GCOT Busy out Loop Relay Default OFF RING OPEN Value Range 1 ON 2 OFF RING GND 3 OFF RING OPEN Description Function When a CO line is busied out manuall...

Страница 141: ... Mode Default Type 1 Value Range 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 Description Function Specifies the Ringing Tone type Note The change of this parameter is activated after resetting the system Reference None Parameter 38 First Digit Time out Process Default Don t release the trunk Value Range 1 Release the trunk 2 Don t release the trunk Description Function Specifies the trea...

Страница 142: ...unction Specifies whether the Ringing tone of DPTs Digital Proprietary Telephones can be turned off or not Reference None Parameter 43 LCD Time Display Mode Default 12h Value Range 1 12h 2 24h Description Function Specifies the time display on the LCD in 12 hour or 24 hour notation Reference 1 17 Display Features F G Display Date and Time Parameter 46 Date Display Default M D Y Value Range 1 M D Y...

Страница 143: ... available for monitoring the call activity only not available for making receiving a call If this parameter is enabled an S CO button on a DSS Console can be used to answer the incoming CO call on the S CO button and retrieve the CO call held on the S CO button Reference 1 16 Button Features F G Button Line Access Parameter 49 LCD Display Mode while CO talking Default Caller ID Value Range 1 Call...

Страница 144: ...dialing is done If Do not send dials entered during conversation is selected DTMF tones entered during a conversation are not redialed If Send dials entered during conversation is selected DTMF tones entered during a conversation are redialed Reference None Parameter 57 VPS Auto Configuration Mode Default Create mailboxes only for the tenant which has VPS ports Value Range 1 Create mailboxes only ...

Страница 145: ...e inter digit timer expires while making an outgoing call with ARS If you select Local Access and the timer expires the system will select a CO line on a Local CO Line Access basis and return CO dial tone Reference 1 6 Originating Features F G Automatic Route Selection ARS Parameter 60 Empty Group Default Allow Value Range 1 Allow 2 Disallow Description Function Determines whether an Extension Gro...

Страница 146: ...wers the intercom call on Consultation Hold or not Reference 1 9 Answering Features F G Hands free Answerback 4 3 40 Hands free Answerback U M Parameter 63 VM Trunk Service for DID Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether to enable or disable the tenant assigned on a DID No basis If Disable is selected then the tenant no works for the CO lines belonging...

Страница 147: ...ot respond to the Timed Reminder wake up call Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 4 4 11 Timed Reminder Remote Wake Up Call U M 4 3 74 Timed Reminder Wake Up Call U M 2 2 Tenant P G Alert Extension Day Night Parameter 67 Sending DID Number to VPS Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or no...

Страница 148: ... an ISDN PRI line Parameter PRI Inter digit Timer 1 Default 5 s Value Range 1 30 s Description Function Specifies the maximum time allowed between each digit on an outgoing call using an ISDN PRI line Note This timer applies to the call after the number of digits determined by Dial counter for PRI Inter digit Timer 2 is dialed Reference None ...

Страница 149: ...alue Range 0 24 digits Description Function Specifies the number of digits to activate PRI Inter digit Timer 2 The number of digits specified by the dial counter is N While N digits are dialed PRI Inter digit Timer 1 applies After N digits are dialed PRI Inter digit Timer 2 applies Reference None Parameter PRI TRG Assignment Default All No check Value Range 1 Check Effective 2 No check Not Effecti...

Страница 150: ...System 150 Programming Guide ...

Страница 151: ...Group Programming Guide 151 Section 3 Group ...

Страница 152: ...Group 152 Programming Guide 3 1 Group Used to assign various group parameters ...

Страница 153: ... each trunk group Up to 48 trunk groups can be created in the system Note To support efficient utilization of trunks it is desirable to group them together in trunk groups according to a type of each trunk Incoming Only Outgoing Only or Both Way determined by the contract with the Central Office ...

Страница 154: ... displayed The current Trunk Group copy source number is shown as Copy from Trunk Group 1 48 3 Select the Trunk Group parameters to copy in Copy Item field Items marked with are copied 4 Point to in the Destination Trunk Group field and click All displayed Trunk Group Nos will be marked with You can also specify one or several Trunk Groups as the copy destination by clicking it them directly 5 Poi...

Страница 155: ...ault Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the destination extension 3 or 4 digits for Intercept Routing feature in both Day and Night modes respectively Notes Intercept Routing provides an automatic re direction of calls that have not been answered These are seven possible destinations of intercepted call 1 An extension 2 an external pager TAFAS 3 an OGM gr...

Страница 156: ...uired before sending the Flash Signal Reference None Parameter Max Dial No after EFA Signal Default 0 Value Range 0 32 Description Function Specifies the maximum dialing digits allowed after sending EFA External Feature Access signal Note If set to 0 the dialing digits can be sent without limit Reference 1 12 Conversation Features F G External Feature Access 4 3 35 External Feature Access U M ...

Страница 157: ...an idle trunk line with the highest physical number 3 Sequential To avoid repeated use of the same trunk line rotation is performed in numerical order from the lowest to the highest trunk port physical number Busy lines are skipped of course Reference 2 8 System Option P G Trunk hunting mode Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant 1 8 to which the tr...

Страница 158: ...ust use Flash Time parameter in Section 1 2 5 Card Properties ELCOT when your Central Office requires a Flash Time not listed here Reference None Parameter Disconnecting Time Default 1 5 s Value Range 1 0 5 s 2 1 5 s 3 2 0 s 4 4 0 s 5 12 0 s Description Function Specifies the maximum time in seconds the system is to wait after releasing the trunk line before getting it again Note This allows the C...

Страница 159: ...igits consisting of 0 9 or Description Function Specifies the PBX access codes required to access the Host PBX or Centrex service If the system is installed behind a host PBX or a Centrex system an access code is required to make an outside Centrex call or to access Centrex features Up to four codes can be assigned per Trunk Group Reference 1 3 System Features F G Host PBX Access 4 3 35 External F...

Страница 160: ...D Incoming Public Default Default Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Numbering Plan ID applied to the incoming CO calls via ISDN Public Switched Telephone Network Reference None Parameter Numbering Plan ID Incoming Private Default Private Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Des...

Страница 161: ...e Value Range 1 Enable 2 Disable Description Function Specifies whether or not the system sends a ringback tone to the extension user who seizes a T1 digital trunk line Available for T1 digital trunk lines only Note In case of the T1 digital trunk line the Central Office does not send a ringback tone to the caller Reference 1 3 System Features F G T1 Carrier Parameter Type of Number Outgoing Publi...

Страница 162: ...ming Public Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5 Network Specific 6 Subscriber Description Function Specifies the Type of Number applied to the incoming CO calls via ISDN Public Switched Telephone Network Reference None Parameter Type of Number Incoming Private Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5 Network Specific 6 Su...

Страница 163: ...on Default No check Value Range 1 No check Disable 2 Check Enable Description Function Used to disconnect the trunk line when the system detects a continuous signal during a CO to CO line call by DISA or AGC Reference 1 5 Attended Features F G Direct Inward System Access DISA Parameter Silence Detection Default Check Value Range 1 No check Disable 2 Check Enable Description Function Used to discon...

Страница 164: ...tion Selects the way to supply the progress tone to an extension when the extension user makes an outgoing call via ISDN 1 Automatic If the network provides a progress tone the system sends the network progress tone to the caller If not the system sends the PBX progress tone 2 Network The system sends the network progress tone to the caller under all conditions 3 PBX The system sends the PBX progr...

Страница 165: ...r TIE Line Default Disable Value Range 1 Enable 2 Disable Description Function Specifies whether the Intercept Routing feature on an incoming TIE call is enabled or not Reference 1 11 Transferring Features F G Intercept Routing 4 2 Trunk Line P G ...

Страница 166: ...o assign various parameters for up to 128 1 128 Extension Groups Which parameters apply to your Extension Group Please refer to the table on the Page 167 and Page 168 Note By default the Group Type of Group No 126 is VM No 127 is AA and No 128 is Operator ...

Страница 167: ...nt No Overflow Setting Destination Day Night Overflow Setting Timer FWD DND Mode Extension Call Hunting Calls to Empty Group Operator Setting Ringing Type Operator Setting Call Priority UCD Setting Time Table No UCD Setting FWD No Answer UCD Setting Auto LOGOUT Mode UCD Setting Supervisor Extension UCD Setting LOGIN Monitor UCD Setting UCD Call Waiting ...

Страница 168: ... Type programming of Incoming Group this feature does not work Applicability of Group Types to Overflow Destinations Group Type Overflow Destination DN External Pager OGM Group Extension Group Phantom Extension RMT Incoming Group None Terminate Circular Operator 1 VM AA UCD 1 ...

Страница 169: ...ension Group Copy screen is displayed The current Extension Group copy source number is shown as Copy from Extension Group 1 128 3 Select the Extension Group parameters to copy in Copy Item field Only parameters which are available to copy are shown in Copy Item field This depends on the Group Type assignment of the copy source Extension Group Items marked with are copied 4 Point to in the Destina...

Страница 170: ...Reference 1 3 System Features F G Extension Group Parameter Copy Default Value Range Description Function You can enter into Extension Group Copy screen by clicking this button Reference Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for the Extension Group Reference 1 3 System Features F G Floating Station Para...

Страница 171: ...extension where the call is transferred to when all extensions in the Extension Group are unavailable or logged out in Day Night mode respectively Reference None Parameter Overflow Setting Timer Default None Value Range None 5 180 s in 5 s increments Description Function Specifies the length of time in seconds the system is to wait before transferring the call in the waiting queue to the Overflow ...

Страница 172: ...how the Extension Group handles the incoming calls directed to it 1 None No Group Type is specified 2 Terminate Functions as a Station Hunting Group Terminate 3 Circular Functions as a Station Hunting Group Circular 4 Ring Functions as a Ring Group 5 Operator Functions as an Operator Group 6 VM Functions as a VM Voice Mail Group 7 AA Functions as an AA Automated Attendant Group 8 UCD Functions as ...

Страница 173: ...gramming Reference None Parameter Extension Call Hunting Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether station hunting feature works or not when the other party calls a busy extension in the group by dialing DN of the extension extension call Assignable only when Terminate or Circular is specified in Group Type programming Note When the other party calls the ...

Страница 174: ...call will be transferred to the overflow destination immediately Assignable only when Operator or UCD is specified in Group Type programming Reference 1 3 System Features F G Extension Group Operator Group 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Time Table No Default None Value Range None 1 32 Description Function Specifies the UCD Time Table 1 32 for the UCD ...

Страница 175: ...xtension in the group Reference 1 3 System Features F G Extension Group 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Auto LOGOUT Mode Default Disable Value Range 1 Disable 2 1 10 times Description Function Specifies the treatment of extensions in a UCD group who do not cannot answer the call A member extension may be logged out automatically if it does not answer t...

Страница 176: ...d in the waiting queue Reference 1 3 System Features F G Extension Group 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting LOGIN Monitor Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether the extension can monitor through the corresponding DSS buttons the Login Logout status of UCD Group members or not Reference 1 3 System Features F G...

Страница 177: ...D Parameter Operator Setting Call Priority Default CO Call 1 Intercept Routing 2 Recall 3 Extension Call 4 Value Range Priority 1 4 Description Function Specifies the answering priority of incoming calls to the Operator Group by a type of call when more than one call is ringing at an Operator extension Assignable only when Operator is specified in Group Type programming Notes If all extensions in ...

Страница 178: ...escription Function Specifies whether the calls coming in on an Operator Group ring one Operator Single or all Operators in the group Multi simultaneously Assignable only when Operator is specified in Group Type programming Reference 1 3 System Features F G Operator Group 1 6 Originating Features F G Operator Call ...

Страница 179: ...unction Specifies the Paging Group 1 16 which you are going to program Reference 1 14 Paging Features F G Paging 4 3 55 Paging U M Parameter Extension Group No Default Paging Group No 1 No 1 1 No 2 128 Others None Paging Groups No 2 16 All None Value Range None 1 128 Description Function Specifies the Extension Group which you are going to assign to the Paging Group Up to 24 Extension Groups per P...

Страница 180: ...Group 180 Programming Guide 3 5 Incoming Group Used to program a list of up to 96 Incoming Groups Which parameters apply to your Incoming Group Please refer to the table on Page 181 and Page 182 ...

Страница 181: ...arameter Group Type DIL 1 N Ter Ring Ope UCD Overflow Setting Destination Day Night Overflow Setting Timer FWD DND Mode Search Mode 1 Calls to Empty Group Operator Setting Ringing Type Operator Setting Call Priority UCD Setting Time Table No UCD Setting FWD No Answer UCD Setting Auto LOGOUT Mode UCD Setting Supervisor Extension UCD Setting UCD Call Waiting ...

Страница 182: ...stination Copying the Incoming Group Parameters to Other Incoming Groups 1 Edit the parameters of the copy source Incoming Group and save it 2 Point to on 3 4 Incoming Group screen of the copy source and click Incoming Group Copy screen is displayed The current Incoming Group copy source number is shown as Copy from Incoming Group 1 96 Applicability of Group Types to Overflow Destinations Group Ty...

Страница 183: ...coming Groups as the copy destination by clicking it them directly 5 Point to and click Are you sure is displayed 6 Point to and click Copying is displayed while the source data is being copied to the destination Parameters of the destination Incoming Groups are immediately effective when copying is finished Parameter Group No Default 1 Value Range 1 96 Description Function Specifies the Incoming ...

Страница 184: ...ensions system resources Reference None Parameter Group Type Default DIL 1 N Value Range 1 DIL 1 N 2 Terminate 3 Ring 4 Operator 5 UCD Description Function Specifies the Group Type for each Incoming Group This determines how the Incoming Group handles the incoming calls directed to it 1 DIL 1 N Functions as a DIL 1 N Group 2 Terminate Functions as a Station Hunting Group Terminate 3 Ring Functions...

Страница 185: ...ransferring the call in the waiting queue to the Overflow Destination Assignable only when Operator is specified in Group Type programming Note If None is specified the call is transferred to the Overflow Destination immediately Reference 1 3 System Features F G Operator Group Parameter Mailbox No Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the mailbox num...

Страница 186: ...meter Search Mode Default UCD Value Range 1 UCD 2 Sequential Description Function Specifies the search mode for extensions Assignable only when Operator Single or UCD is specified in Group Type programming 1 UCD The system selects the extension following the last one called as the destination extension 2 Sequential The system selects the extension assigned first in the Incoming Group as the destin...

Страница 187: ... call will be transferred to the overflow destination immediately Assignable only when Operator or UCD is specified in Group Type programming Reference 1 3 System Features F G Incoming Group Operator Group 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Time Table No Default None Value Range None 1 32 Description Function Specifies the UCD Time Table 1 32 for the UCD ...

Страница 188: ...extension in the group Reference 1 3 System Features F G Incoming Group 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Auto LOGOUT Mode Default Disable Value Range 1 Disable 2 1 10 times Description Function Specifies the treatment of extensions in a UCD group who do not cannot answer the call A member extension may be logged out automatically if it does not answer t...

Страница 189: ... Features F G Incoming Group 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting UCD Call Waiting Default Enable Value Range 1 Disable 2 Enable Description Function This feature is different from regular Call Waiting This feature if enabled allows UCD group members to hear a Call Waiting tone when an inside outside call arrives but all the extensions in the UCD Group are ...

Страница 190: ...ut in the waiting queue in order of precedence determined by this Call Priority setting If the same priority is set on all four types of calls the calls will be put in the waiting queue in order of the arrival Reference 1 3 System Features F G Operator Group 1 6 Originating Features F G Operator Call Parameter Operator Setting Ringing Type Default Single Value Range 1 Multi 2 Single Description Fu...

Страница 191: ... 0 9 Description Function Specifies extensions or Extension Groups or both that you are going to assign to the specified Incoming Group Notes DN of VPS port cannot be assigned as a mailbox number and an Incoming Group destination Only DN of an extension or FDN of an extension group can be assigned as an Incoming Group destination A single extension can be assigned to up to eight different Incoming...

Страница 192: ...s arriving at extensions whose Group Type programming is specified as DIL 1 N 1 Immediate An extension rings immediately 2 1 ring Delay An extension rings in 1 ring delay timing 3 3 ring Delay An extension rings in 3 ring delay timing 4 6 ring Delay An extension rings in 6 ring delay timing 5 No Ring An extension does not ring Reference 1 3 System Features F G DIL 1 N Group 1 13 Audible Tone Featu...

Страница 193: ...M Group Parameter Group No Default 1 Value Range 1 8 Description Function Specifies the OGM Group 1 8 which you are going to program Reference None Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for each OGM group Reference 1 3 System Features F G Floating Station ...

Страница 194: ...ion Function Specifies the tenant 1 8 to which you are going to assign this OGM Group Reference 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter OGM Type Default DISA Value Range 1 DISA 2 UCD OGM 3 Wake up Description Function Specifies the usage of OGM resources on DISA cards 1 DISA OGM for DISA feature 2 UCD OGM OGM for UCD group 3 Wake up OGM for Wake up message Reference 1 5 Att...

Страница 195: ... user code to make both outside and intercom calls via DISA Reference 1 5 Attended Features F G Direct Inward System Access DISA Parameter DISA built in Automated Attendant Tables Dial 0 Dial 9 Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension numbers to each DISA built in Auto Attendant number Both DN of extensions and FDN Floating Directory Numbe...

Страница 196: ...Group 196 Programming Guide ...

Страница 197: ...Line Programming Guide 197 Section 4 Line ...

Страница 198: ...Line 198 Programming Guide 4 1 Line Used to assign various parameters for both trunk and extension lines ...

Страница 199: ...Line Programming Guide 199 4 2 Trunk Line Used to assign various parameters for trunk lines ...

Страница 200: ... 4 1 Trunk Line screen of the copy source and click Trunk Line Copy screen is displayed The current Trunk Line copy source number is shown as Copy from XXX XXXXX XX 3 Select the Trunk Line parameters to copy in Copy Item field Only parameters which are available to copy are shown in Copy Item field This depends on the attribute of the copy source Trunk Line Items marked with are copied 4 Point to ...

Страница 201: ... Slot Assignment P G Parameter Port No Default 1 Value Range 1 n n 4 DID n 16 BRI n 23 PRI23 n 24 T1 n 8 Others Description Function Specifies the trunk port which you are going to program Reference 1 3 Trunk Port Assignment P G Parameter Copy Default Value Range Description Function You can enter into Trunk Line Copy screen by clicking this button Reference Parameter Group No Default Display only...

Страница 202: ...O card 2 DID DID T1 DID card 3 DID ISDN BRI PRI23 card 4 TIE T1 TIE card Value Range 1 DIL 2 DID 3 DID ISDN 4 MDN 5 TIE Description Function Specifies how the incoming CO call via this trunk line is routed to the destination in the system 1 DIL Incoming CO calls are routed by DIL Direct In Lines 1 1 or 1 N feature 2 DID Incoming CO calls are routed by DID Direct Inward Dialing feature 3 DID ISDN I...

Страница 203: ...not be changed Reference 1 5 Attended Features F G Direct In Lines DIL Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID 3 1 TIE Line Features F G TIE Line Service BRI DID LCOT GCOT ELCOT T1 LCO T1 GCO T1 DID PRI23 DID ISDN MDN DID TIE DID ISDN Card Type Selection Default DID DID ISDN TIE DID ISDN T1 TIE DIL TIE DIL DIL DIL DID DID ...

Страница 204: ...ial type for each trunk line This is the dial type regardless of the dial mode of the extension telephone The dialing signals from any extension are converted to the dial type specified by this setting and transmitted to the trunk line Available selections and the default values per Card Type Reference None BRI PRI23 ISDN Card Type Selection Default ISDN DTMF 80 ELCOT LCOT T1 GCOT Pulse 10 Pulse 2...

Страница 205: ...d in 9 1 DID Dial Registration screen Reference 1 5 Attended Features F G Direct In Lines DIL 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter Subscriber Default Blank Value Range Up to 16 digits consisting of 0 9 or Description Function Specifies the number which is used as the CLIP Calling Line Identification Presentation number Notes When an extension user makes an outside cal...

Страница 206: ...to 8 digits to be added to the number received from the DID DID ISDN other PBX via TIE lines Reference 1 5 Attended Features F G Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID 3 1 TIE Line Features F G TIE Line Service Parameter Digit to receive DID Default 4 DID T1 DID card 16 BRI PRI23 card Value Range 0 16 digits Description Function Specifies the number of d...

Страница 207: ...E Line Service Parameter Start Signal Type Default Wink Value Range 1 Immediate 2 Wink Description Function Specifies the start signal type for a DID and TIE E M trunk 1 Immediate The system sends the dialing digits to CO after waiting for the time length determined by First Dial Timer in Card Properties screen of the corresponding trunk card For information on Card Properties screen please refer ...

Страница 208: ...LCOT T1 GCO T1 LCO card Value Range 1 Enable 2 Disable Description Function Specifies whether CPC Detection on outgoing CO calls is enabled or disabled If enabled the system disconnects the line with the time set in program CPC Signal OUT Detection Detection Time when the CPC signal is detected Reference 1 3 System Features F G Calling Party Control CPC Signal Detection Parameter CPC Signal OUT De...

Страница 209: ...meter CPC Signal IN Detection Detection Time Default 400 ms Value Range 1 None 2 6 5 ms 3 2 75 8 ms Description Function Specifies the expected minimum duration for detecting CPC Calling Party Control signal on incoming CO calls Assignable for ELCOT GCOT LCOT T1 GCO and T1 LCO cards Reference 1 3 System Features F G Calling Party Control CPC Signal Detection Parameter TIE Line TIE to CO Security M...

Страница 210: ...TIE Line Service Parameter Caller ID Default Disable Value Range 1 Disable 2 Enable Description Function Specifies the waiting timer to receive the Caller ID that is sent from the CO with an incoming call When you select Disable the system does not wait so the ringing starts immediately i e the system does not wait for the Caller ID which may take a few seconds Reference 1 5 Attended Features F G ...

Страница 211: ...Line Programming Guide 211 4 3 Extension Line 4 3 1 Extension Line 1 2 Used to assign parameters for extension lines ...

Страница 212: ...shown as Copy from DN XXXX 3 Select the Extension Line parameters to copy in Copy Item field Only parameters which are available to copy are shown in Copy Item field This depends on the attribute of the copy source Extension Line Items marked with are copied 4 Point to in the Destination Extension Line field and click All displayed Extension Line Nos will be highlighted You can also specify one or...

Страница 213: ... which you are going to program Note Port Nos 17 32 will be displayed when DN and Group No for Ext No 2 are assigned in 1 5 VPS DPT Port Assignment Section 1 5 Reference 1 4 Extension Port Assignment P G Parameter DN Default Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension which you are going to program Reference 2 3 Numbering Plan P G Parameter Group No Defaul...

Страница 214: ...ion Specifies the name for the extension line Note This is shown on the called party s display PT so that he knows who is calling Reference 1 17 Display Features F G Display Call Information Parameter Message Lamp Default No Value Range 1 Yes 2 No Description Function Assigns whether an SLT with MESSAGE lamp can receive the message waiting indication or not Assignable when an SLT with Message lamp...

Страница 215: ...d when Programmed number is specified in Extension s mailbox number setting in Section 5 10 VPS Integration Reference None Parameter CO Key Default Value Range Description Function You can enter into Flexible CO Key screen Section 4 3 2 by clicking on this screen Reference 2 2 3 Flexible Button Assignment U M 3 2 5 005 Flexible CO Button Assignment U M Parameter PF Key Default Value Range Descript...

Страница 216: ...tension Reference 1 3 System Features F G Class of Service COS 4 4 10 Switching COS U M Parameter COS No Secondary Default 1 Value Range 1 96 Description Function Specifies the Secondary COS Class of Service to the extension Reference 1 3 System Features F G Class of Service COS 4 4 10 Switching COS U M Parameter Preferred Line Outgoing Default Prime Line ICM PDN Value Range 1 No Line 2 Idle Line ...

Страница 217: ...o which the extension is connected when the extension user goes off hook to answer a call Reference 2 2 11 Preferred Line Assignment Incoming U M Parameter Preferred Line Incoming Key No Default Blank Value Range 1 24 Description Function Specifies the CO button to which the extension is connected when the extension user goes off hook to answer a call This assignment is required when Prime Line CO...

Страница 218: ...Value Range 1 Inactive 2 Active Description Function Specifies whether or not the extension can use the LCS Live Call Screening feature Reference 1 9 Answering Features F G Live Call Screening LCS Parameter LCS Setting Operation Mode Default Hands free Value Range 1 Private 2 Hands free Description Function Assigns whether the voice message being recorded is monitored automatically through the bui...

Страница 219: ... Call Screening LCS 4 3 43 Live Call Screening LCS U M Parameter Data Line Mode Default No Value Range 1 Yes 2 No Description Function Assigns whether Data Line Security mode is available or not If set to No setting Data Line Security mode by dialing the feature number is impossible Reference 1 12 Conversation Features F G Data Line Security 4 3 25 Data Line Security U M Parameter Call Waiting Ton...

Страница 220: ...ifies the language shown on a PANASONIC display PT The language is set for each extension so phones on the same system can display different languages Reference 2 2 1 Bilingual Display Selection U M Parameter Station Lock Password Default Blank Value Range Fixed to 3 digits consisting of 0 9 Description Function Specifies the 3 digit password that lets the extension user lock and unlock the extens...

Страница 221: ...ed Bearer Mode is set automatically depending on the type of extension telephone as follows PT Speech SLT 3 1 KHz Audio ISDN extension depending on the bearer mode of the ISDN extension Reference 2 1 ISDN Features F G Integrated Services Digital Network ISDN Parameter JOG Dial Speed Default Normal Value Range 1 Normal 2 High Description Function Specifies the rotation speed of the JOG Dial on the ...

Страница 222: ...nating Features F G Calling Line Identification Presentation CLIP 4 3 19 Calling Line Identification Presentation CLIP U M Parameter CLIP Number Private Default Blank Value Range Up to 16 digits consisting of 0 9 or Description Function Specifies a CLIP number used for the incoming outgoing calls via Private Network to each extension Notes When an extension user makes an outside call using an ISDN...

Страница 223: ...ence 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Parameter Call Log Incoming Lock Password Default Blank Value Range Fixed to 3 digits consisting of 0 9 Description Function Specifies the Call Log Incoming Log Lock password The extension user can lock the call log display so that incoming call information is not shown on the display Note The Manager and the Operators can c...

Страница 224: ...een is displayed by clicking on 4 2 Extension Line screen Key Type Assignment The following Key Type Assignment screen is displayed by clicking Key Type Display button including Not Stored for each CO key on the above screen Additional Parameters Required by Key Type Depending on a Key Type additional parameters are required as follows ...

Страница 225: ...cifies the ringer frequency ring tone type 1 8 for incoming calls Ringing Type Immediate Specifies the timing of ringing when a call comes in on the extension Immediate 1 ring Delay 3 ring Delay 6 ring Delay No Ring SDN EXT Specifies the PDN owner s extension number 3 or 4 digits Tone 2 Specifies the ringer frequency ring tone type 1 8 for incoming calls Ringing Type Immediate Specifies the timing...

Страница 226: ...Dialing button MESSAGE Message Waiting button MESSAGE OTHER Another Extension Phantom Extension Message Waiting button FWD DND Call Forwarding Do Not Disturb button G FWD Group Call Forwarding button G LOGIN LOGOUT Group Login Logout button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button LOGIN LOGOUT Login Logout button 2WAY R...

Страница 227: ...e the usage of flexible PF buttons on PTs The following screen is displayed by clicking on 4 2 Extension Line screen Key Type Assignment The following Key Type Assignment screen is displayed by clicking Key Type Display button including eNot Stored for each PF Key on the above screen ...

Страница 228: ...Dialing up to 10 characters consisting of 0 9 A Z a z or the following marks VTR DN Specifies the Directory Number of the Voice Mail extensions Parameter Key Type Default Not Stored Value Range Please refer to Description Function Description Function Not Stored Key Type is not assigned ONE TOUCH One Touch Dialing button FWD DND Call Forwarding Do Not Disturb button SAVE Saved Number Redial button...

Страница 229: ...gits for Intercept Routing feature in both Day and Night modes respectively Notes Intercept Routing provides an automatic re direction of calls that have not been answered There are seven possible destinations of intercepted call 1 An extension 2 an external pager TAFAS 3 an OGM group 4 an extension group 5 an incoming group 6 a phantom extension or 7 an ISDN extension except the wild card charact...

Страница 230: ...he Call Forwarding No Answer feature is activated If a call is not answered before the programmed number of rings the call is redirected to the pre assigned extension Note If 0 is specified Call Forwarding No Answer Time setting in Section 2 5 System Timer works Reference 1 11 Transferring Features F G Call Forwarding 4 3 9 Call Forwarding U M 2 5 System Timer P G ...

Страница 231: ...Line Programming Guide 231 4 4 DSS Console Used to assign the paired extension for a DSS Direct Station Selection Console and the usage of DSS and PF buttons ...

Страница 232: ...s displayed The current DSS Console copy source number is shown as Copy from XXX XXXXX XX 3 Select the DSS Console parameters to copy in Copy Item field Items marked with are copied 4 Point to in the Destination DSS Console field and click All displayed DSS Console Nos will be highlighted You can also specify one or several DSS Consoles as the copy destination by clicking it them directly 5 Point ...

Страница 233: ...Range Extension port physical number Description Function Displays the extension port to which the DSS Console is connected Reference 1 15 Proprietary Telephone Features F G DSS Console 1 4 Extension Port Assignment P G Parameter DSS Console 1 8 Model Default T7440 Value Range 1 T7440 2 T7441 3 Others Description Function Specifies the Model No of DSS Console Reference 1 15 Proprietary Telephone F...

Страница 234: ...on 4 3 DSS Console screen Parameter PF Key Default Value Range Description Function You can enter into Flexible PF Key screen Section 4 4 2 by clicking on this screen Reference 2 2 3 Flexible Button Assignment U M 5 2 1 Station Programming U M Parameter Copy Default Value Range Description Function You can enter into DSS Console Copy screen by clicking this button Reference ...

Страница 235: ... CO Trunk Group No Specifies the Trunk Group number 01 48 DSS EXT Specifies the extension number 3 or 4 digits ONE TOUCH Dial Specifies the telephone number or feature access number up to 24 digits consisting of 0 9 P S or F Note P Pause S Secret Dialing F Hook Flash MESSAGE OTHER EXT Specifies the extension number or phantom extension number 3 or 4 digits G FWD DN Specifies the Floating Directory...

Страница 236: ...Extension Message Waiting button FWD DND Call Forwarding Do Not Disturb button G FWD Group Call Forwarding button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button 2WAY REC Two way Recording button 2WAY TRN Two way Transfer button LCS Live Call Screening button LCS CANCEL Live Call Screening Cancel button DAY NIGHT Day Night swi...

Страница 237: ...rogramming Guide 237 4 4 2 Flexible PF Key Assignment for DSS Console Used to determine the usage of flexible PF buttons on DSS Consoles The following screen is displayed by clicking on 4 3 DSS Console screen ...

Страница 238: ...ing on a Key Type additional parameters are required as follows Key Type Additional Parameters Description ONE TOUCH Dial Specifies the telephone number or feature access number up to 24 digits consisting of 0 9 P S or F Note P Pause S Secret Dialing F Hook Flash Name Specifies the name for One Touch Dialing up to 10 characters consisting of 0 9 A Z a z or the following marks VTR DN Specifies the ...

Страница 239: ... Key Type is not assigned ONE TOUCH One Touch Dialing button FWD DND Call Forwarding Do Not Disturb button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button ANSWER Answer button RELEASE Release button Reference 2 2 3 Flexible Button Assignment U M 5 2 1 Station Programming U M ...

Страница 240: ...ard No Default Value Range XXX DPH XXX Card No 101 314 Description Function Specifies the physical number of a doorphone card which you are going to program Reference 1 2 Slot Assignment P G Parameter Port No Default 1 Value Range 1 4 Description Function Specifies the doorphone port which you are going to program Reference None ...

Страница 241: ...tion Features F G Doorphone Call 2 2 Tenant P G Parameter Destination Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extensions that ring when a visitor presses the doorphone button Up to 126 destination extensions per doorphone can be assigned in Day mode and Night mode respectively Destination extensions can unlock the door opener Reference 4 ...

Страница 242: ...e Range 1 2 Description Function Displays the Pager No Reference 2 8 1 External Pager Paging Equipment I M Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which the External Pager is assigned Required when Tenant Service is employed Reference 1 3 System Features F G Tenant Service 2 2 Tenant P G ...

Страница 243: ... actually comes out of External Pager or not is controlled by the Manager or Operators Reference 4 4 2 Background Music BGM External U M Parameter BGM Source Default MUS1 Value Range 1 None 2 MUS1 3 MUS2 Description Function Assigns the External Music Source port to which the External Pager is connected To change music sources you must first select and apply None Then you can select and apply MUS1...

Страница 244: ...Default Value Range XXX BRI XXX Card No 101 314 Description Function Specifies the physical number of the BRI card which you are going to program Reference 1 2 Slot Assignment P G Parameter Port No Default Value Range 1 8 Description Function Specifies the ISDN extension port which you are going to program Reference None ...

Страница 245: ... G Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks Description Function Specifies the name for the ISDN extension line Reference 1 17 Display Features F G Display Call Information Parameter Tone Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether the system sends the call progress tone to the ISDN extens...

Страница 246: ...rer mode of the ISDN extension Reference 2 1 ISDN Features F G Integrated Services Digital Network ISDN Parameter Numbering Plan ID Default Default Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Numbering Plan ID applied to the outgoing incoming CO calls via ISDN Reference None Parameter Type of Number Default Default Value Range 1...

Страница 247: ...nating Features F G Calling Line Identification Presentation CLIP 4 3 19 Calling Line Identification Presentation CLIP U M Parameter CLIP Number Private Default Blank Value Range Up to 16 digits consisting of 0 9 or Description Function Specifies a CLIP number used for the incoming outgoing calls via Private Network to each ISDN extension Notes When an extension user makes an outside call using an...

Страница 248: ...rvice 1 96 to the ISDN extension Reference 1 3 System Features F G Class of Service COS 4 4 10 Switching COS U M Parameter COS No Secondary Default 1 Value Range 1 96 Description Function Specifies the Secondary COS Class of Service 1 96 to the ISDN extension Reference 1 3 System Features F G Class of Service COS 4 4 10 Switching COS U M ...

Страница 249: ...Features Programming Guide 249 Section 5 Features ...

Страница 250: ...Features 250 Programming Guide 5 1 Features Used to assign parameters for various system features ...

Страница 251: ...ou can import System Speed Dialing data in your PC This is functional when the PC Maintenance Console is connected in the interactive mode Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which the System Speed Dialing codes are assigned Required when Tenant Service is employed Reference 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Entry...

Страница 252: ...ch are already programmed Reference None Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks Description Function Specifies the name for each speed dial code Notes The stored name is shown on a large display PT such as KX T7235 KX T7436 when dialing System Speed Dialing number Both Name and Number should be stored in pairs for each System S...

Страница 253: ...e 253 Parameter Number Default Blank Value Range Up to 24 digits consisting of 0 9 P S or F Description Function Specifies the telephone number for each speed dial code Note P Pause S Secret Dialing F Hook Flash Reference None ...

Страница 254: ...up to 448 Phantom Extension numbers Parameter Entry No Default 001 048 Value Range 001 448 in 48 codes increments Description Function Specifies the entry number of phantom extension number which you are going to program Reference 1 3 System Features F G Phantom Extension ...

Страница 255: ...ension number can be assigned to multiple extensions so that the caller can ring a group of extensions simultaneously Reference 1 3 System Features F G Floating Station 2 2 3 Flexible Button Assignment U M 3 2 5 005 Flexible CO Button Assignment U M Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resource...

Страница 256: ...strictions Parameter Dial Default 1 911 Others Blank Value Range Up to 24 digits consisting of 0 9 Description Function Specifies emergency telephone numbers that can be dialed from any extension regardless of restrictions imposed by Toll Restriction Account Code Verified mode or Electronic Station Lockout Reference 1 6 Originating Features F G Emergency Call 4 3 31 Emergency Call U M ...

Страница 257: ... All Blank Value Range Up to 24 digits consisting of 0 9 F P S or hyphen Description Function Specifies the phone number for Quick Dialing Note Any extension user can use Quick Dialing number simply by dialing the feature number for Quick Dial 1 8 Reference 1 7 Dialing Features F G Quick Dialing 4 3 65 Quick Dialing U M ...

Страница 258: ... Default 1 Value Range 1 8 Description Function Specifies the tenant to which a list of Account Codes is assigned Required when Tenant Service is employed Reference 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Entry No Default 0001 0020 Value Range 0001 1000 in 20 codes increments Description Function Specifies the entry number of the Account code which you are going to program ...

Страница 259: ... Parameter TRS Level Default None Value Range None 1 6 Description Function Specifies the TRS toll restriction level for each account code Note TRS level appended to each account code applies to the call in conjunction with Toll Restriction Override by Account Code Entry feature Reference 1 3 System Features F G Account Code Entry 1 6 Originating Features F G Toll Restriction Override by Account C...

Страница 260: ...cription Function Specifies special carrier access codes Notes This assignment allows the system to recognize the user dialed special carrier code in order to insert the necessary pause and to apply toll restriction X can be used as a wild card character which substitutes any digit in its position Reference 1 6 Originating Features F G Toll Restriction Toll Restriction for Special Carrier Access ...

Страница 261: ... Return Soon MSG2 Gone Home MSG3 At Ext Extension No MSG4 Back at Hour Minute MSG5 Out Until Month Day MSG6 In a Meeting MSG7 9 Blank Value Range Up to 16 characters consisting of 0 9 A Z a z or the following marks Description Function Specifies Absent Messages Messages 1 through 6 are programmed at the factory but can be changed Reference 1 17 Display Features F G Absent Message Capability 4 3 1 ...

Страница 262: ...Features 262 Programming Guide 5 9 DISA TIE User Code Used to program a list of up to 32 DISA TIE User Codes Each code is appended with a COS level ...

Страница 263: ...2 Specify a complicated password as long and random as you can make it 3 Change the password frequently Notes DISA user code is required when the DISA caller attempts to make an outside call Trunk Security mode or to make either extension or outside call All Security mode If TIE to CO Security Mode in Section 4 2 Trunk Line is set to Yes entering TIE user code is required when the TIE caller attem...

Страница 264: ...nging etc by sending a code with DTMF tone before sending the normal call progress tone busy tone ringback tone etc These codes enable the VPS to immediately recognize the current status of the call and improve its call handling performance Parameter Integration Code Ringback Tone Default 1 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Ringback Tone code Sent t...

Страница 265: ...advertently connected to another Voice Mail port also heard when no DTMF receiver is available to the Voice Mail extension Reference 1 3 System Features F G Integration VPS Parameter Integration Code DND Tone Default 4 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the DND Tone code Sent to the Voice Mail port when the extension dialed has set DND Do Not Disturb fea...

Страница 266: ... 9 or Description Function Specifies the Confirmation Tone code Sent to the Voice Mail port when the Message Waiting Lamp On or Message Waiting Lamp Off code is dialed successfully Reference 1 3 System Features F G Integration VPS Parameter Integration Code FWD to VM Ringback Tone Default 6 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the FWD to VM Ringback Tone c...

Страница 267: ...to accept the call This signals the Voice Mail port usually an Automated Attendant to let the caller leave a message Reference 1 3 System Features F G Integration VPS Parameter Integration Code FWD to Extension Ringback Tone Default 8 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the FWD to Extension Ringback Tone code Sent to the Voice Mail port when the extension...

Страница 268: ...set to Start by System Programming this command is sent to a VM port when an incoming CO call is answered by the VM port Reference 1 3 System Features F G Integration VPS Parameter Voice Mail Command VM Service Default 6 Value Range Up to 16 digits consisting of 0 9 or H Description Function Specifies the VM Voice Mail Service command This command is transmitted preceding the Get Message command a...

Страница 269: ...o assign optional parameters for VPS Integration Parameter DTMF signal duration Default 80 ms Value Range 1 80 ms 2 160 ms Description Function Specifies the duration of the DTMF signals sent to the Voice Mail ports Reference 1 3 System Features F G Integration VPS ...

Страница 270: ...nal RBT BT Default 1 5 s Value Range 1 0 5 s 2 1 0 s 3 1 5 s 4 2 0 s Description Function Specifies the length of time in seconds the system is to wait before sending Integration Code with DTMF signals System Voice Mail Extension Status Reference 1 3 System Features F G Integration VPS Parameter Turn off control of Message Waiting lamp Default System Value Range 1 System 2 Voice Mail Description F...

Страница 271: ...ension number 2 Programmed number Description Function Specifies whether an extension s mailbox number is substituted by the extension number or it is programmable free If a call is forwarded or rerouted to the Voice Mail port the system automatically transmits the mailbox number to the Voice Mail port to specify the extension user s mailbox To make it programmable select Programmed number then as...

Страница 272: ...Voice Mail port after forwarding a call to the Voice Mail port Reference 1 3 System Features F G Integration VPS Parameter Sending out Follow on ID after IRNA Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or not the system sends Follow on ID to a Voice Mail port after redirecting a call IRNA to the Voice Mail port Reference 1 3 System Features F G Integratio...

Страница 273: ... a telephone number for callback purposes Parameter Local Call Area Code Default Blank Value Range Up to 6 digits consisting of 0 9 Description Function Specifies the area code of the location where your KX TD500 system is installed Note This local area code is referenced to modify the telephone number Reference 1 5 Attended Features F G Caller ID Service ...

Страница 274: ...s consisting of 0 9 or Description Function Specifies the number to be added to the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for local call The number is added to the beginning of the received digits Reference 1 5 Attended Features F G Caller ID Service Parameter Long Distance Call Digits to delete Default 0 Value Range 0 9 Description Functi...

Страница 275: ... consisting of 0 9 or Description Function Specifies the number to be added to the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for long distance call The number is added to the beginning of the received digits Reference 1 5 Attended Features F G Caller ID Service ...

Страница 276: ...on the display PT allowing the called party to recognize the caller before answering a call If the network provides telephone number only the system searches for the matching name from the Caller ID Code Table If the matching name is found the system will display both the telephone number and the name Import from System Speed Dial Provides quick registration of Caller ID names and numbers Up to 10...

Страница 277: ... copying is finished 5 12 Caller ID Registration screen is displayed again Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which the Caller ID codes are assigned Required when Tenant Service is employed Reference 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Entry No Default 0001 0010 Value Range 0001 1000 in 10 codes increments Descript...

Страница 278: ...r by its ID Code or name If the name display is required use this program to give a name to a Caller ID code Reference 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Parameter Number Default Blank Value Range Up to 24 digits consisting of 0 9 or Description Function Specifies the identification code of the calling party Caller ID code to utilize Caller ID Service Reference 4 ...

Страница 279: ...g CO calls will be handled by the UCD Time Table procedure Up to 32 UCD Time Tables max 16 steps for each can be assigned Parameter Table No Default 1 Value Range 1 32 Description Function Specifies the UCD Time Table which you are going to program Reference 3 3 Extension Group P G 3 5 Incoming Group P G ...

Страница 280: ...1 S8 OGM 1 8 is sent to the caller if available If not wait until OGM 1 8 becomes available 3 1T 4T Callers are put in the waiting queue for N 1 4 8 seconds while hearing the ringback tone or music on hold 4 TR Transfers a call to the Overflow destination 5 RET Returns to the first step of the sequence 6 OFF Disconnects the call compulsorily Note If an unavailable OGM S 1 8 is assigned in the UCD ...

Страница 281: ...Toll Restriction Programming Guide 281 Section 6 Toll Restriction ...

Страница 282: ...Toll Restriction 282 Programming Guide 6 1 Toll Restriction Used to assign TRS Toll Restriction Deny Codes and TRS Exception Codes ...

Страница 283: ...r TRS Level Default 6 Value Range 2 6 Description Function Specifies a TRS toll restriction level Reference 1 6 Originating Features F G Toll Restriction Parameter Entry No Default 001 020 Value Range 001 400 in 20 entries increments Description Function Specifies a unit of 20 TRS Deny Codes which apply to the TRS level selected Reference 1 6 Originating Features F G Toll Restriction ...

Страница 284: ...ge Up to 10 digits consisting of 0 9 X or Description Function Specifies the leading 10 digits of the toll restricted telephone numbers Note X can be used as a wild card character which substitutes any digit in its position Reference 1 6 Originating Features F G Toll Restriction ...

Страница 285: ...des can be assigned Parameter TRS Level Default 6 Value Range 2 6 Description Function Specifies a TRS toll restriction level Reference 1 6 Originating Features F G Toll Restriction Parameter Entry No Default 001 020 Value Range 001 200 in 20 entries increments Description Function Specifies a unit of 20 TRS Exception codes which apply to the TRS level selected Reference 1 6 Originating Features F...

Страница 286: ...its consisting of 0 9 X or Description Function Specifies the leading 10 digits of the telephone numbers which are excepted from the toll restriction Note X can be used as a wild card character which substitutes any digit in its position Reference 1 6 Originating Features F G Toll Restriction ...

Страница 287: ...ARS Automatic Route Selection Programming Guide 287 Section 7 ARS Automatic Route Selection ...

Страница 288: ...ARS Automatic Route Selection 288 Programming Guide 7 1 ARS Automatic Route Selection Used to assign ARS parameters ...

Страница 289: ...tarting time of each zone according to the service hours and charges offered by your carriers Parameter Time A B C D SUN MON TUE WED THU FRI SAT Default Time A 8 00AM Time B 5 00PM Time C 9 00PM Time D Disable Value Range Hour 01 12 AM PM Disable Description Function Specifies starting time Hour 01 12 AM PM Disable of the applied Route List Reference 1 6 Originating Features F G Automatic Route Se...

Страница 290: ...call by analyzing the extension user dialed number Up to 800 Leading Digits entries can be programmed in the system Parameter Entry No Default 001 020 Value Range 001 800 in 20 entries increments Description Function Specifies the entry number which you are going to program Reference 1 6 Originating Features F G Automatic Route Selection ARS ...

Страница 291: ... ARS Plan 1 Leading Digits 1 ARS Plan 2 If the user dialed number is 1800 the system selects ARS Plan 1 Example 2 Leading Digits 1800 ARS Plan 1 Leading Digits 1 ARS Plan 2 If the user dialed number is 1800 the system selects ARS Plan 2 Reference 1 6 Originating Features F G Automatic Route Selection ARS Parameter Routing Plan No Default None Value Range None 1 48 Description Function Specifies th...

Страница 292: ...eter Plan No Default 1 Value Range 1 48 Description Function Specifies the Routing Plan Table 1 48 which you are going to program Reference 1 6 Originating Features F G Automatic Route Selection ARS Parameter Time A B C D Trunk Group No Default None Value Range None 1 48 Description Function Specifies the TRG Trunk Group 1 48 which is used for routing the call Up to 16 trunk groups can be entered ...

Страница 293: ...cation Table No Default None Value Range None 1 48 Description Function Specifies the MOD Modified Digit table 1 48 which is used to modify the user dialed number so that it matches the requirements of the carrier Reference 1 6 Originating Features F G Automatic Route Selection ARS ...

Страница 294: ... 8 entries increments Description Function Specifies the entry number of Digits Modification table which you are going to program Reference 1 6 Originating Features F G Automatic Route Selection ARS Parameter Digits to delete Default 0 Value Range 0 9 Description Function Specifies the number of digits to be deleted from the beginning of the user dialed number If you set to 0 no digit is deleted f...

Страница 295: ...Number to be added Default Blank Value Range Up to 20 digits consisting of 0 9 or P Pause Description Function Specifies the dialing number to be added to the beginning of the user dialed number Reference 1 6 Originating Features F G Automatic Route Selection ARS ...

Страница 296: ...ARS Automatic Route Selection 296 Programming Guide ...

Страница 297: ...Private Network Programming Guide 297 Section 8 Private Network ...

Страница 298: ...Private Network 298 Programming Guide 8 1 Private Network Used to assign parameters required to utilize TIE line service ...

Страница 299: ...e dialed number decide a routing pattern appropriate for each call Up to 36 routing patterns can be programmed in this table Parameter Entry No Default 01 08 Value Range 01 36 Description Function Specifies the entry number of Routing Table which you are going to program Reference 3 1 TIE Line Features F G TIE Line Service Parameter PBX Code Default Blank Value Range Up to 3 digits consisting of 0...

Страница 300: ...tion Specifies the number of digits to be deleted from the dialed digits Reference 3 1 TIE Line Features F G TIE Line Service Parameter Number to be added Default Blank Value Range Up to 20 digits consisting of 0 9 Description Function Specifies the dialing number to be added to the dialed digits Reference 3 1 TIE Line Features F G TIE Line Service Parameter Trunk Group No Default None Value Range...

Страница 301: ...DID Dial Programming Guide 301 Section 9 DID Dial ...

Страница 302: ...DID Dial 302 Programming Guide 9 1 DID Dial Used to assign parameters required to utilize DID MDN service ...

Страница 303: ...iption Function Specifies the entry number of DID MDN No which you are going to program Reference 1 5 Attended Features F G Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID Multiple Directory Number MDN Ringing Service Parameter Automatic Registration Default Value Range Description Function You can enter into Automatic Registration screen Section 9 2 2 by clickin...

Страница 304: ... 8 Description Function Specifies the tenant used for DID call when Enable is specified in VM Trunk Service for DID programming in Section 2 8 System Option Reference 1 5 Attended Features F G Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID 2 8 System Option P G VM Trunk Service for DID Parameter VPS Trunk Group No Default 1 Value Range 1 48 Description Function ...

Страница 305: ...Night mode respectively Reference 1 5 Attended Features F G Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID 2 3 Numbering Plan P G Other PBX 01 Other PBX 16 Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks Description Function Specifies the name for the destination extension where a DID call comes in Re...

Страница 306: ... 100 entries can be registered at once with a simple operation 1 Click on 9 1 DID Dial Registration screen Automatic Registration screen is displayed 2 Enter the appropriate parameters Programming Example Base Number Dial 123456 Additional Number Number of Registrations 100 Additional Number Number of Digits 2 Beginning Entry No 1 ...

Страница 307: ...e equal to or less than 16 digits Then the operation will be aborted If Beginning Entry No exceeds 991 the following error message will be displayed E9011 Beginning Entry No must be equal to or less than 991 Then the operation will be aborted The new entries will override the old ones if DID MDN numbers are already registered in the specified areas If the number of remaining Entry fields is less t...

Страница 308: ...ence None Parameter Additional Number Number of Digits Default 2 digits 00 99 Value Range 1 16 digits Description Function Specifies the number of digits to be added to the end of the Base Number Reference None Parameter Beginning Entry No Default 1 Entry No 1 Value Range 1 991 Description Function Specifies the first entry number for automatic registration This number corresponds to the DID MDN N...

Страница 309: ...Maintenance Programming Guide 309 Section 10 Maintenance ...

Страница 310: ...Maintenance 310 Programming Guide 10 1 Maintenance Used to assign parameters for system maintenance ...

Страница 311: ... remote system administration Parameter Manual Initialization Command 1 5 Default All Blank Value Range Up to 80 characters consisting of 0 9 A Z a z or the following marks Description Function Specifies Modem Manual Initialization Command Reference 1 3 System Features F G External Modem Control 4 3 36 External Modem Control U M ...

Страница 312: ...l of your modem must be disabled to communicate correctly It depends on the type of the modem you use In most cases hardware flow control can be disabled by sending the K0 command from the PBX to the external modem Please refer to the manual of the external modem you use for further information It is recommended to add this command to Automatic Initialization Command the command to initialize the ...

Страница 313: ...fies Connection Message from Modem Reference 1 3 System Features F G External Modem Control 4 3 36 External Modem Control U M Parameter Disconnection Message 1 5 Default Message 1 NO CARRIER Others Blank Value Range Up to 80 characters consisting of 0 9 A Z a z or the following marks Description Function Specifies Disconnection Message from Modem Reference 1 3 System Features F G External Modem Co...

Страница 314: ...R 1 2 Station Message Detail Recording SMDR automatically records detailed information for outside calls Parameter SMDR Connection Default No Value Range 1 Yes 2 No Description Function Enables or disables SMDR Reference 2 8 3 Personal Computer Printer I M ...

Страница 315: ...king on this screen Reference 1 3 System Features F G Station Message Detail Recording SMDR Parameter Print out Error Information Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or not the Error Information will be printed out by SMDR Reference 5 2 3 Troubleshooting via Error Log Records I M Parameter Format Page Length Default 24 lines Value Range 4 99 lines ...

Страница 316: ...age Length number and the Skip Perforation number Reference None Parameter Duration Log Outgoing Calls Default All Value Range 1 None 2 All 3 Toll Only Description Function Specifies the type of outgoing calls that will be printed out by SMDR 1 None No printout 2 All All calls 3 Toll Only Toll calls only Reference None Parameter Duration Log Incoming Calls Default On Value Range 1 On 2 Off Descrip...

Страница 317: ...ormation Default Disable Value Range 1 Number 2 Name 3 Disable Description Function Activates or deactivates printing out the DID number received from the Central Office Reference 1 5 Attended Features F G Direct Inward Dialing DID 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter Print out Incoming Call Start RC and Incoming Call Answer AN information Default Disable Value Range ...

Страница 318: ...ount Code Default Enable Last Entered Code Value Range 1 Enable First Entered Code Last Entered Code 2 Disable Description Function Specifies whether or not the Account Code will be printed out by SMDR If this is enabled SMDR will print out the first entered account code or the last entered account code when two or more different account codes are entered during a single call Reference 1 3 System ...

Страница 319: ... the time display mode 12 hour or 24 hour notation which will be printed out by SMDR Reference 1 3 System Features F G Station Message Detail Recording SMDR Parameter Print out supplementary digits ISDN only Default Disable Value Range 1 Enable 2 Disable Description Function Includes the SMDR printout of outgoing supplementary digits This is only available on ISDN calls Reference 1 3 System Featur...

Страница 320: ...of system power failure Parameter Trunk Card 1 24 Default None Value Range None XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the trunk card number and its type which will be used in case of Power Failure Transfer Reference 1 4 Fault Recovery Diagnostics F G Power Failure Transfer 2 9 1 Auxiliary Connection for Power Failure Transfer I M 1 2 Slot Assignment P G ...

Страница 321: ... case of Power Failure Transfer Notes DPTs and some APTs cannot be used during a power failure Auxiliary connections between the Trunk card and Extension card should be made as per System Programming so that conversation is maintained when power is restored or TSW is recovering Reference 1 4 Fault Recovery Diagnostics F G Power Failure Transfer 2 9 1 Auxiliary Connection for Power Failure Transfer...

Страница 322: ...mming and Maintenance mode the KX TD500 System provides the following four passwords with a different security level respectively Password System Programming Protection Level 1 Allows the administrator to access all System Programming and Maintenance features without restrictions Passwords are originally programmed at the factory but can be changed by System Programming available only when gaining...

Страница 323: ...kers e You have to take the following measures to find the system password when you forget the password Therefore please never forget the password If you have the backup system data you can find the password by loading the backup system data to your PC and check the Password with programming screen If you don t have the backup system data you have to program again or contact your Panasonic dealers...

Страница 324: ...d required for entering the System Programming and Maintenance mode from a PC Reference 3 5 Operational Mode I M 4 Utility I M Parameter Password System Programming Protection Level 3 Default 1234 Value Range 4 7 digits of alphanumeric characters Description Function Specifies the password required for entering the System Programming and Maintenance mode from a PC Reference 3 5 Operational Mode I ...

Страница 325: ...ce 1 2 System Administration F G User Programming with Proprietary Telephone 3 User Programming U M Parameter Password Walking COS Default 1234 Value Range 4 7 digits consisting of 0 9 Description Function Specifies the password required for using the Walking COS feature Reference 1 6 Originating Features F G Walking COS 4 3 84 Walking COS U M Parameter Serial Interface Port PROG Parity Default Di...

Страница 326: ...ed Reference None Parameter Serial Interface Port PROG Word Length Default Display only Value Range 8 bits Description Function Defines the number of bits in each byte or character Note Port 1 is fixed to 8 bits Reference None Parameter Serial Interface Port PROG Stop Bit Default Display only Value Range 1 bit Description Function A stop bit code indicates the end of a bit string which composes a ...

Страница 327: ...0 bps Value Range 1 2400 bps 2 4800 bps 3 9600 bps 4 19200 bps Description Function Specifies the data transmission speed from the system to the printer or personal computer Reference None Parameter Serial Interface Port SMDR Parity Default None Value Range 1 None 2 Mark 3 Space 4 Even 5 Odd Description Function A parity code indicates what type of parity is used to detect an error in the string o...

Страница 328: ...bits 2 8 bits Description Function Defines the number of bits in each byte or character Reference None Parameter Serial Interface Port SMDR Stop Bit Default 1 bit Value Range 1 1 bit 2 2 bits Description Function A stop bit code indicates the end of a bit string which composes a character Select an appropriate value depending on the requirements of your printer or personal computer Reference None ...

Страница 329: ...ystem resources Reference None Parameter Remote Connect Information Dial Number Default Blank Value Range Up to 40 digits consisting of 0 9 F P S or hyphen Description Function Specifies the dial number that is sent from the modem remote location You can see this dial number in the Batch Processing mode Reference 3 4 3 Remote Administration Remote Connection I M Parameter Remote Connect Informatio...

Страница 330: ...Maintenance 330 Programming Guide 10 7 System Time Used to assign System Time For information on the default values of summer time please refer to the table on the Page 331 ...

Страница 331: ...pr 03 2005 Oct 30 2006 Apr 02 2006 Oct 29 2007 Apr 01 2007 Oct 28 2008 Apr 06 2008 Oct 26 2009 Apr 05 2009 Oct 25 2010 Apr 04 2010 Oct 31 2011 Apr 03 2011 Oct 30 2012 Apr 01 2012 Oct 28 2013 Apr 07 2013 Oct 27 2014 Apr 06 2014 Oct 26 2015 Apr 05 2015 Oct 25 2016 Apr 03 2016 Oct 30 2017 Apr 02 2017 Oct 29 2018 Apr 01 2018 Oct 28 2019 Apr 07 2019 Oct 27 2020 Apr 05 2020 Oct 25 ...

Страница 332: ...ault Jan Value Range Jan Dec Description Function Selects the month by clicking the small triangle Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Day Default 01 Value Range 01 31 Description Function Specifies the date in two digits by entering the value dire...

Страница 333: ...ange 0 1 12 Description Function Specifies the hour in two digits by entering the value directly Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Minute Default 00 Value Range 00 59 Description Function Specifies the minute in two digits by entering the value d...

Страница 334: ...ay not work properly Parameter AM PM Default AM Value Range AM PM Description Function Selects AM PM by clicking the small triangle Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Setting Default Disable Value Range 1 Disable 2 Enable Description Function Enab...

Страница 335: ...e 01 31 Description Function Specifies the date in two digits by entering the value directly Reference None Parameter End Day Default Please refer to Default values of summer time Value Range 01 31 Description Function Specifies the date in two digits by entering the value directly Reference None Parameter Start Year Default Please refer to Default values of summer time Value Range 00 99 Descripti...

Страница 336: ...Maintenance 336 Programming Guide ...

Страница 337: ...Programming Error Messages Programming Guide 337 Section 11 Programming Error Messages ...

Страница 338: ...pen the data file XX that doesn t exist E0005 Illegal programming version Tried to open the data file that was made in the newer software version of PC programming than one being used at present E0006 Communication error A communication error occurred between your PC and the PBX Or the port parameters of your PC do not match the port parameters of the PBX E0007 Communication error of the modem XX ...

Страница 339: ... INI is damaged Please refer to the description of E0015 E0017 Failed Reading of remote connection parameters Reading of remote connection parameters failed because file TD500 INI is damaged Please refer to the description of E0015 E0018 There is not enough space on your hard disk or floppy to save the system data Download is incomplete because there is not enough space on your hard disk or floppy...

Страница 340: ...he ports of the card become in service E1013 Cannot change the attribute of the port which is the paired extension of a DSS console The attribute of this port cannot be changed until it is de assigned as the paired extension of a DSS console Please change the attribute after de assignment E1014 You have exceeded the system limit of DSS consoles There is a limit of 64 consoles per system E1015 Inco...

Страница 341: ...te when currently assigned as VPS port under 1 4 VPS DPT Port Assignment When the port which is assigned to VPS DPT port is changed to extension port please change the port after deleting the assignment in 1 4 VPS DPT Port Assignment screen E1031 Assign the channel type before making the port INS In Service status The port of T1 card cannot be made INS In Service status when the channel type of th...

Страница 342: ...helf expansion shelf 1 and expansion shelf 2 E1054 The status of the card must be OUS Out of Service When you change the card properties of PRI23 or BRI card the status must be OUS Out of Service E1056 Value of Max must be larger than value of Min Detection time value of Tone ON Time Tone OFF Time Max must be larger than that of Tone ON Time Tone OFF Time Min E1058 Assign ISDN Ext under 1 8 BRI Po...

Страница 343: ...s and shouldn t be any conflicts The following are examples of feature number conflicts Examples N and NX NXX NM and NML NL is allowed E2011 Out of range Overflow Timer should be assigned in the range of Second 5 180 None shows that Overflow Timer doesn t work E2012 Trunk group number duplicated Each trunk group in the Local Hunt Sequence must have a unique number E2013 Invalid directory number fo...

Страница 344: ... be assigned as a Mailbox Number E4003 Invalid LCS playback password The LCS playback password must be 3 digits 0 9 E4004 Invalid Call Log lock password The Call Log lock password must be 3 digits 0 9 E4005 Invalid Station Lock password The Station Lock password must be 3 digits 0 9 E4006 Specify trunk line no Trunk line no must be specified when Single CO key is assigned E4007 Single CO key dupli...

Страница 345: ...ension can be assigned as a doorphone call destination E4021 Secret dial S must be placed at the beginning and end of desired secret numbers Cannot assign Secret Dialing S that is registered in One Touch dialing without being even number E4022 Cannot assign PDN key as Prime Line CO Please assign key number except for PDN key when the outgoing or incoming preferred line is set to Prime Line CO E402...

Страница 346: ...gned as the number of G FWD key E5001 Assign both name and number for Caller ID Cannot assign just the name for Caller ID E5002 Cannot use more than seven characters There can be a maximum of seven characters in an absent message E5003 User code format error Please assign the DISA TIE user code of 4 10 digits consisting of 0 9 E5004 User code duplicated Each code in the DISA TIE User Code must hav...

Страница 347: ...Namely this pattern must be followed Time A Time B Time C Time D E7002 Assign both trunk group number and modification table number Cannot assign just trunk group number or just modification table number Both must be assigned as a pair under ARS routing plan E9001 Invalid directory number for DID destination There are seven possible destinations for DID calls 1 An extension 2 an external pager TAF...

Страница 348: ...r duplicated Each DID MDN number in 9 1 DID Dial Registration screen must have a unique number E9010 Number of DID dial must be equal to or less than 16 digits The total digits of Base Number and Number of Digits are over 16 E9011 Beginning Entry No must be equal to or less than 991 Cannot specify the number 992 999 as the Beginning Entry No because Number of Registrations is set by 10 entries inc...

Страница 349: ...0 again W1001 Change the card XXX YYY status Please confirm whether or not to execute OUS Out of Service INS In Service command to the card XXX YYY XXX Slot No YYY Card Type The OUS Out of Service INS In Service command to the card is effective to the whole ports of the card W1002 Change the status of port XXXXX Please confirm whether or not to execute OUS Out of Service INS In Service command to ...

Страница 350: ...ted W5002 System Speed Dialing number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W5003 Emergency dial number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W5004 Quick Dial number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits ...

Страница 351: ... dial must not exceed 3 digits Truncate it Truncate means that the leading 3 digits are saved and the rest are deleted W8003 TIE additional dial must not exceed 20 digits Truncate it Truncate means that the leading 20 digits are saved and the rest are deleted W9001 DID dial must not exceed 16 digits Truncate it Truncate means that the leading 16 digits are saved and the rest are deleted W9002 DID ...

Страница 352: ...de Uploading the system programming data from PC to PBX is completed How to change PBX to on line mode 1 Set CPU Mode Rotary Switch position to 0 2 Then press Reset button I1000 Please set up VPS port in 1 4 VPS DPT Port Assignment screen The attribute s of extension s have been set up as VPS DPT Please set up the port s in 1 4 VPS DPT Port Assignment screen ...

Страница 353: ...Default Values Programming Guide 353 Section 12 Default Values ...

Страница 354: ...C ESLC DLC 1 2 4 Card Properties LCOT GCOT Program Default Card Type Blank Status Program Default Break Detection 16 96 ms Flash Detection Yes Program Default Break Detection 16 96 ms Flash Detection Yes LPR Version Display only Off hook Time 160 ms Flash Detection Timer 208 1016 ms Program Default First Dial Timer 1 0 s Break 60 Pulse Feedback Tone Yes Inter digit Pause 830 ms ...

Страница 355: ...ulse Break Time Adjustment 0 ms Bell Detection Time 144 ms DTMF Inter digit Pause Time 112 ms Bell Disappearance Timer 5 s Gain Adjustment 0 dB Program Default Caller ID Detection Check Detection Start Time 240 ms Carrier Detection Disable Detection Time 2000 ms Header Examination Enable LPR Version Display only Program Default Line Coding B8ZS Frame Sequence ESF ESF Frame Option C A D B First Dia...

Страница 356: ... ms Answer Decision Timer 32 ms Break Detection 16 96 ms Transmission of RAI No Program Default Network Type Display only DTMF Signal Duration 80 ms DTMF Signal Inter digit Pause 112 ms Status Message Enable Status Receive Disconnect Line Mode L1 Mode Display only Line Mode L2 Mode Display only Line Mode Access Mode Display only Line Mode TEI Display only Line Mode TE Power No check Disable Line M...

Страница 357: ...r digit Pause 112 ms Line Coding B8ZS Frame Sequence Extended Superframe ESF Software Information Display only Timer Setting Program Default T01 60 s T02 35 s T03 10 s T04 10 s T05 60 s T06 35 s T07 10 s CO Qsig Master PRI only Qsig Slave PRI only T200 1 s CO Qsig Master PRI only Qsig Slave PRI only T203 10 s CO Qsig Master PRI only Qsig Slave PRI only T302 10 s BRI 15 s PRI23 CO Qsig Master PRI o...

Страница 358: ...T3D3 10 s BRI 30 s PRI23 CO Qsig Master PRI only Qsig Slave PRI only T3D9 20 s Extension T200 1 s Extension T203 10 s Extension T302 10 s BRI 15 s PRI23 Extension T303 5 s BRI 2 s PRI23 Extension T304 0 s Extension T305 30 s BRI 4 s PRI23 Extension T306 30 s Extension T310 10 s BRI 40 s PRI23 Extension T3D3 30 s Extension T3D9 0 s BRI 20 s PRI23 Program Default CYCLIC Tone Detection Mode Standard ...

Страница 359: ...splay only Area Code Display only Program Default Option Card Status Conference Expansion Card Display only Option Card Status Digital OHCA Card Display only System Clock Status Display only Clock Configuration Mode External Clock Configuration Master Card No Display only Clock Configuration Priority 1 8 None or 101 314 T1 BRI PRI23 Program Default Card No Group No DID card 47 Others 1 Status Prog...

Страница 360: ...l Parallel XDP HLC card None Status DN Refer Program Default TVS No 1 VPS Card None Type None Jack No Display only Port No Blank Ext No 1 DN Blank Ext No 1 Group No Blank Ext No 2 DN Blank Ext No 2 Group No Blank Status DN Refer Program Default Card No Channel Type Undefined DN Blank Group No Blank Status DN Refer Program Default ...

Страница 361: ...em 2 2 Tenant Program Default Card No 1 8 Location Display only Card No 1 8 OGM Group No 1 Program Default Card No Type CO DN Blank Group No 1 Status DN Refer Program Default Card No Type CO DN Blank Group No 1 Status Program Default Tenant No 1 Operator FDN Blank Alert Extension Day Night Blank DAY NIGHT Switching Mode Manual ...

Страница 362: ...s 3 8 0 Automatic Route Selection No check External Paging Tone Check System Speed Dial TRS Level Override No check Confirmation Tone for Station or External Paging Check Program Default 1 1st Hundred Block Extension 10 2 2nd Hundred Block Extension 11 3 3rd Hundred Block Extension 12 4 4th Hundred Block Extension 13 5 5th Hundred Block Extension 14 6 6th Hundred Block Extension 20 7 7th Hundred B...

Страница 363: ...Call Pickup 40 30 Directed Call Pickup 41 31 Hold 50 32 Hold Retrieve Station 51 33 Hold Retrieve Trunk 53 34 Redial 35 Call Park Call Park Retrieve 52 36 Account Code 49 37 Door Open 55 38 External Feature Access 6 39 Station Program Clear 790 40 Message Waiting Set Cancel Call Back 70 41 OGM Playback Record 36 42 Call FWD Do Not Disturb Set Cancel 710 43 Dial Call Pickup Deny Set Cancel 720 44 D...

Страница 364: ...45 59 Automatic Callback Busy Cancel 46 60 Walking COS 47 61 MODEM Control 791 62 Reserved Reserved for future use Blank 63 70 Quick dial 1 Quick dial 8 Blank 71 Reserved Reserved for future use Blank 72 Remote DND 722 73 Remote FWD Cancel Once 723 74 Trunk Route Control 724 75 UCD Monitor Mode 725 76 TIE Line Access 77 77 92 Other PBX 01 Other PBX 16 Blank 93 Paging Deny Set Cancel 721 94 Trunk B...

Страница 365: ...p Setting TRS Level Day Night 1 Account Code Mode Optional Switching Day Night Mode Disable Call from TRS Level 7 Extension Enable Time Limit of Outside Calls No Transfer to CO Disable Call FWD to CO TIE Disable Off Hook Call Announcement OHCA Enable Call FWD Follow Me Enable Busy Override Disable DND Override Disable Busy Override Deny Enable Released Link Operation Disable Digits Restriction in ...

Страница 366: ...d from TRS Enable Transfer to TIE Disable Incoming Group FWD Disable Program Default Hold Recall Time 60 s Transfer Recall Time 12 rings Pickup Dial Waiting Time 1 s Call Duration Count Start Time 0 s First Digit Time 10 s Inter digit Time 5 s Call Forwarding No Answer Time 3 rings Extension to CO Line Call Duration Time 10 min CO to CO Line Call Duration Time 10 min Door Opener Time 5 s Program D...

Страница 367: ... 12 rings Night Lunch Break 0 ring Program Default Trunk Group No 01 1 Others None Program Default Source Trunk Group No 1 Destination Trunk Group No 1 48 No check Program Default 1 Sound source during transfer Music on Hold 2 SLT On hook with consulting held call Consulting Hold 3 FLASH button operation while CO talking Release the trunk 4 FLASH button operation when Don t release the trunk is se...

Страница 368: ...peration No limit 14 Dialing in DISA CO to CO talking Disconnect and make a new call 15 Special dial tone after setting feature Enable 17 Destination Busy DISA Send busy tone 18 Destination Busy DID Send busy tone 19 Destination Busy TIE Send busy tone 20 Off hook Monitor Enable Program Default 21 Illegal Number DISA Send reorder tone 22 Illegal Number DID Send reorder tone 23 Illegal Number TIE S...

Страница 369: ...ut Process Don t release the trunk 41 Fixed Feature Number Type 1 42 DPT Ringer OFF Enable 43 LCD Time Display Mode 12h 46 Date Display M D Y 47 Tone Type for Outgoing Calls Busy Reorder 48 Call Pickup with DSS S CO key Disable 49 LCD Display Mode while CO talking Caller ID Program Default 56 Redial with ISDN Do not send dials entered during conversation 57 VPS Auto Configuration Mode Create mailb...

Страница 370: ...le 65 Alert Ringing Disable 67 Sending DID Number to VPS Disable Program Default PRI Inter digit Timer 1 5 s PRI Inter digit Timer 2 3 s Dial counter for PRI Inter digit Timer 2 7 digits PRI TRG Assignment All No check Program Default Group No 1 Copy Intercept Destination Day Night Blank Pause Time before Flash Signal 512 ms Max Dial No after EFA Signal 0 Line Hunting Order Reverse Tenant No 1 Fla...

Страница 371: ...utgoing Public Default Type of Number Outgoing Private Default Type of Number Incoming Public Default Type of Number Incoming Private Default Cyclic Signal Detection Check Continuous Signal Detection No check Silence Detection Check Program Default ISDN Progress Tone Mode Automatic IRNA for TIE Line Disable Program Default Group No 1 Copy FDN Blank DN Refer Tenant No 1 Overflow Setting Destination...

Страница 372: ...nitor Disable UCD Setting UCD Call Waiting Enable Operator Setting Call Priority CO Call 1 Intercept Routing 2 Recall 3 Extension Call 4 Operator Setting Ringing Type Single Program Default Paging Group No 1 Extension Group No Paging Group No 1 No 1 1 No 2 128 Others None Paging Groups No 2 16 All None Program Default Group No 1 Copy FDN Blank DN Refer Group Type DIL 1 N Overflow Setting Destinati...

Страница 373: ...g Supervisor Extension Blank UCD Setting UCD Call Waiting Enable Operator Setting Call Priority CO Call 1 Intercept Routing 2 Recall 3 Extension Call 4 Operator Setting Ringing Type Single Program Default Destinations DN Blank Destinations Ringing Type Immediate Program Default Group No 1 FDN Blank DN Refer Tenant No 1 OGM Type DISA Security Mode Trunk DISA built in Automated Attendant Tables Dial...

Страница 374: ...Night 1001 Lunch Break Blank Subscriber Blank DID TIE Digits to delete 0 DID TIE Number to be added Blank Digit to receive DID 4 DID T1 DID card 16 BRI PRI23 card Wink Signal Time out 1024 ms Start Signal Type Wink Answer Wait Timer None CPC Signal OUT Detection Enable DID card Disable ELCOT GCOT LCOT T1 GCO T1 LCO card CPC Signal OUT Detection Detection Time 400 ms CPC Signal IN Detection Enable ...

Страница 375: ...y 1 Preferred Line Outgoing Prime Line ICM PDN Preferred Line Outgoing Key No Blank Preferred Line Incoming Ringing Line Preferred Line Incoming Key No Blank Pickup Dialing Mode Disable Pickup Dialing Dial Display only LCS Setting Status Inactive LCS Setting Operation Mode Hands free LCS Setting Recording Mode Stop Rec LCS Setting LCS Password Blank Data Line Mode No Call Waiting Tone Type Tone 1 ...

Страница 376: ...r Private Blank Call Log Incoming Overwrite Mode Yes Call Log Incoming Lock Password Blank Program Default Key Type CO 01 Loop CO Others Not Stored Program Default Key Type Not Stored Program Default Intercept Destination Day Night Blank Call Forwarding No Answer Time 0 ring Program Default Paired Extension DSS Console 1 8 Port No Display only DSS Console 1 8 Model T7440 DSS Key PF Key Copy Progra...

Страница 377: ...rnal Paging 4 7 ISDN Extension Line Program Default Key Type Not Stored Program Default Key Type Not Stored Program Default Card No Port No 1 Tenant No 1 Destination Day Night Blank Program Default Pager No Display only Tenant No 1 FDN Blank BGM No check BGM Source MUS1 DN Refer Program Default Card No Port No Group No Display only Name Blank ...

Страница 378: ...c Numbering Plan ID Default Type of Number Default CLIP Number Public Blank CLIP Number Private Blank COS No Primary 1 COS No Secondary 1 Program Default Tenant No 1 Entry No 000 019 Max Entry Display only Current Registration Display only Name Blank Number Blank Program Default Entry No 001 048 FDN Blank DN Refer Program Default Dial 1 911 Others Blank Program Default ...

Страница 379: ... Program Default Dial All Blank Program Default Tenant No 1 Entry No 0001 0020 Code Blank TRS Level None Program Default Code Blank Program Default Message MSG1 Will Return Soon MSG2 Gone Home MSG3 At Ext Extension No MSG4 Back at Hour Minute MSG5 Out Until Month Day MSG6 In a Meeting MSG7 9 Blank Program Default Code All Blank COS All 96 ...

Страница 380: ...WD to VM Ringback Tone 6 Integration Code FWD to VM Busy Tone 7 Integration Code FWD to Extension Ringback Tone 8 Voice Mail Command Voice Mail Command Leave Message H Voice Mail Command Get Message H Voice Mail Command AA Service 8 Voice Mail Command VM Service 6 Program Default DTMF signal duration 80 ms Pause timing before sending DTMF signal Follow on ID 1 5 s Pause timing before sending DTMF ...

Страница 381: ...ollow on ID after IRNA Disable Program Default Local Call Area Code Blank Local Call Digits to delete No 1 3 Others 0 Local Call Number to be added Blank Long Distance Call Digits to delete 0 Long Distance Call Number to be added 1 Program Default Tenant No 1 Entry No 0001 0010 Import from Sys Speed Dial Name Blank Number Blank Program Default Table No 1 Command Sequence 1 16 None Program Default ...

Страница 382: ...S Automatic Route Selection 7 2 Time Table 7 3 Leading Digits Table Program Default TRS Level 6 Entry No 001 020 Dial Blank Program Default TRS Level 6 Entry No 001 020 Dial Blank Program Default Time A B C D SUN MON TUE WED THU FRI SAT Time A 8 00AM Time B 5 00PM Time C 9 00PM Time D Disable Program Default Entry No 001 020 Dial Blank Routing Plan No None ...

Страница 383: ...l Registration 9 2 1 DID Dial Registration Program Default Plan No 1 Time A B C D Trunk Group No None Time A B C D Modification Table No None Program Default Entry No 01 08 Digits to delete 0 Number to be added Blank Program Default Entry No 01 08 PBX Code Blank Leading Digit Blank Digits to delete 0 Number to be added Blank Trunk Group No None Program Default Entry No 0001 0010 ...

Страница 384: ...Night Blank Name Blank Program Default Base Number Dial Blank Additional Number Number of Registrations 10 entries Additional Number Number of Digits 2 digits 00 99 Beginning Entry No 1 Entry No 1 Program Default Manual Initialization Command 1 5 All Blank Automatic Initialization Command AT F0Q0E0V1S0 1X0 D0 Program Default Connection Message 1 5 Message 1 CONNECT Others Blank Disconnection Messa...

Страница 385: ...ing Calls All Duration Log Incoming Calls On Print out Caller ID Information Number Print out DID Information Disable Print out Incoming Call Start RC and Incoming Call Answer AN information Disable Print out Timed Reminder Information Disable Print out Account Code Enable Last Entered Code Print out LOGIN LOGOUT Disable Time Display Mode 12h Program Default Print out supplementary digits ISDN onl...

Страница 386: ... Port PROG Parity Display only Serial Interface Port PROG NL Code CR LF Serial Interface Port PROG Word Length Display only Serial Interface Port PROG Stop Bit Display only Serial Interface Port PROG Baud Rate 9600 bps Serial Interface Port SMDR Port 2 Serial Interface Port SMDR Parity None Serial Interface Port SMDR NL Code CR LF Serial Interface Port SMDR Word Length 8 bits Serial Interface Port...

Страница 387: ... Sat Hour 12 Minute 00 AM PM AM Summer Time Daylight saving Time Setting Setting Disable Start Month Please refer to Default values of summer time End Month Please refer to Default values of summer time Start Day Please refer to Default values of summer time End Day Please refer to Default values of summer time Start Year Please refer to Default values of summer time Program Default ...

Страница 388: ...sonic Communications Co Ltd All Rights Reserved This manual is copyrighted by Panasonic Communications Co Ltd PCC You may print out this manual solely for internal use with this model Except above you may not reproduce this manual in any form in whole or part without the prior written consent of PCC and its licensee Copyright PSQX1889SA Ave 65 de Infantería Km 9 5 San Gabriel Industrial Park Carol...

Отзывы: