4
1.4.
How to Discharge the E.Capacitor on the Frame Unit
CAUTION:
1.
Make sure to discharge the E.capacitor on the Frame Unit.
2.
Be careful of the high voltage circuit on the Frame Unit when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and remove the necessary parts/unit.
2. Install the insulation tube onto the lead part of resistor (ERG5SJ102:1k
Ω
/5W).
(an equivalent type of resistor may be used.)
3. Place a resistor between both terminals of E.capacitor on the Frame Unit for approx. 5 seconds.
4. After discharging, confirm that the E.capacitor voltage is lower than 10V using a voltmeter.
Fig. F1
Содержание Lumix DMC-LZ30E
Страница 11: ...11 ...
Страница 15: ...15 Fig D3 Fig D4 Fig D5 Fig D6 ...
Страница 17: ...17 7 3 5 Battery Door Unit Fig D11 7 3 6 Removal of the Main P C B Fig D12 ...
Страница 18: ...18 Fig D13 ...
Страница 30: ...30 ...