18
7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP PCB)
1. Be sure to discharge the capacitor on FLASH TOP PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH TOP PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP PCB.
No.
Parts No.
Connection
Form
1
RFKZ0354
FP9103 (MAIN) - LCD UNIT
37PIN 0.3 FFC
2
VFK1974
FP9004 (MAIN) - LCD UNIT
4PIN 0.5 FFC
3
RFKZ0416
FP9001 (MAIN) - CCD UNIT
41PIN 0.3 FFC
4
RFKZ0477
FP9002 (MAIN) - LENS UNIT
45PIN 0.3 FFC
5
VFK1870
PP9001 (MAIN) - PS8001 (FLASH TOP)
30PIN B to B
Содержание Lumix DMC-LZ10E
Страница 11: ...11 4 Specifications ...
Страница 12: ...12 5 Location of Controls and Components ...
Страница 13: ...13 ...
Страница 19: ...19 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Страница 21: ...21 Fig D2 8 3 2 Removal of the LCD Unit Fig D3 ...
Страница 22: ...22 8 3 3 Removal of the SD Cover Fig D4 8 3 4 Removal of the Front Case Unit Fig D5 ...
Страница 23: ...23 8 3 5 Removal of the Top Case Unit Fig D6 8 3 6 Removal of the Flash Top P C B Fig D7 ...
Страница 50: ...S7 3 Packing Parts and Accessories Section S 18 204 211 207 206 200 203 Not Supplied 209 210 205 216 201 202 ...