Dimensions

• LT4H-W digital timer

(units: mm 

inch

)

Tolerance: 

±

1.0 

±

.039

• Dimensions for flush mount (with adapter installed)

• Dimensions for front panel installations

• Installation panel cut-out dimensions

The standard panel cut-out dimensions are shown
below. Use the mounting frame (AT8-DA4) and rub-
ber gasket (ATC18002).

• For connected installations

Note) 1: The installation panel thickness should be between 1

and 5 mm 

.039 and .197 inch

.

Note)

2: For connected installations, the waterproofing ability

between the unit and installation panel is lost.

LT4H-W

SET/LOCK

DOWN

T2

T1

LOCK

TIMER

RESET

T2

OP.

T1

m

UP

h

s

48

1.890

44.5

1.752

44.5

1.752

7.5

.295

5.5

55.6

14.5

.217

2.189

.571

(Same for 8-pin type)

5.5

64.5

.217

2.539

7.5

.295

Screw terminal type 

(Flush mount)

Screw terminal type

Pin type

Pin type 

(Flush mount/Surface mount)

UP

DOWN

SET/LOCK

RESET

TIMER

LOCK

T2

OP.

T1

T2

T1

m

h

s

LT4H-W

SET/LOCK

RESET

TIMER

T2

T2

LOCK

T1

OP.

T1

DOWN

UP

LT4H-W

m

h

s

Panel

Rubber gasket

ATC18002 (supplied)

48

1.890

48

1.890

48

1.890

1.890

50

1.969

1

63.5

2.500

66

2.598

50

1.969

66

2.598

1

44.5

1.752

Mounting frame 

AT8-DA4 (supplied)

48

Rubber gasket

ATC18002 (supplied)

Panel

AT8-DA4 (supplied)

90

3.543

(11p cap AT8-DP11
sold separately)

(8p cap AD8-RC
sold separately)

11-pin type

8-pin type

for flush mount

for flush mount

Mounting frame 

(    ) dimension is for 8-pin type.

(90.0)

95.5

(3.543)

3.760

AT8-DLA1
(sold separately)

Device installation rail

(11-pin type AT8-DF11K
sold separately)

DIN rail terminal block
(8-pin type AT8-DF8K
sold separately)

80min.

3.150min.

80min.

3.150min.

45

 0

+0.6

1.772

 0

+.024

45

 0

+0.6

1.772

 0

+.024

45

0

+0.6

1.772

0

+.024

A=(48 

×

 n – 2.5)

+0.6

 0

A=(1.890 

×

 n – .098)

+.024

 0

A

When n timers are continuously installed, the dimension
(A) is calculated according to the following formula (n:
the number of the timers to be installed):

LT4H-W

Applicable standard

Safety standard

EN61812-1

Pollution Degree 2/Overvoltage Category II

EMC

(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity

RF electromagnetic field immunity

EFT/B immunity

Surge immunity
Conductivity noise immunity
Power frequency magnetic field immunity
Voltage dip/Instantaneous stop/Voltage fluctuation immunity

EN55011 Group1 ClassA
EN55011 Group1 ClassA

EN61000-4-2    4 kV contact 

8 kV air 

EN61000-4-3    10 V/m AM modulation (80 MHz to 1 GHz) 

10 V/m pulse modulation (895 MHz to 905 MHz) 

EN61000-4-4    2 kV (power supply line) 

1 kV (signal line) 

EN61000-4-5    1 kV (power line) 
EN61000-4-6    10 V/m AM modulation (0.15 MHz to 80 MHz) 
EN61000-4-8    30 A/m (50 Hz) 
EN61000-4-11  10 ms, 30% (rated voltage)

100 ms, 60% (rated voltage)
1,000 ms, 60% (rated voltage)
5,000 ms, 95% (rated voltage)

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Содержание LT4H

Страница 1: ...Output Operating voltage Power down insurance Terminal type Part number 9 999 s 0 001 s 99 99 s 0 01 s 999 9 s 0 1 s 9999 s 1 s 99 min 59 s 1 s 999 9 min 0 1 min 99 h 59 min 1 min 999 9 h 0 1 h Power ON delay 1 Power ON delay 2 Signal ON delay Signal OFF delay Pulse One shot Pulse ON delay Signal Flicker Totalizing ON delay 8 modes Relay 1 c Transistor 1 a 100 to 240 V AC 24 V AC 100 to 240 V AC 2...

Страница 2: ...Shortened body 70 1 mm 2 760 inch underhead 4 Compliant with UL c UL and CE 48 1 890 48 1 890 64 5 2 539 UL File No E122222 C UL File No E122222 LT4H L Timers mm inch Product types Time range Product name Operating mode Output Operating voltage Power down insurance Terminal type Part number 9 999 s 0 001 s 99 99 s 0 01 s 999 9 s 0 1 s 9999 s 1 s 99 min 59 s 1 s 999 9 min 0 1 min 99 h 59 min 1 min ...

Страница 3: ... AC DC 50 60 Hz common Max 10 V A 100 mA 30 V DC 12 to 24 V DC Max 3 W DC type Transistor output type AC type AC DC type DC type Rating Time accuracy max Contact Life Electrical Mechanical Operating conditions Rated operating voltage Rated frequency Rated power consumption Rated control capacity Time range Time counting direction Operation mode Start Reset Stop input Lock input Input signal Indica...

Страница 4: ...gasket ATC18002 supplied Panel 63 5 2 500 48 1 890 66 2 598 50 1 969 48 1 890 LT4H TIMER UP OP RST LOCK DOWN LOCK RESET s m h Mounting frame for flush mount AT8 DA4 supplied Panel Rubber gasket ATC18002 supplied 1 039 11 pin type 11p cap AT8 DP11 sold separately 8 pin type 8p cap AD8 RC sold separately 48 1 890 90 3 543 48 1 890 66 2 598 50 1 969 DIN rail terminal block 8 pin type AT8 DF8K sold se...

Страница 5: ... OP TIMER LT4H Changing the set time 1 It is possible to change the set time with the up and down keys even dur ing time delay with the timer However be aware of the following points 1 If the set time is changed to less than the elapsed time with the time delay set to the addition direction time delay will continue until the elapsed time reaches full scale returns to zero and then reaches the new ...

Страница 6: ...ddition or stops at 0 sub traction Ignores start input Stops delay time operation at stop ON Restarts delay time operation at stop OFF 1 2 3 OFF OFF OFF Set the operation mode section of the DIP switches no s 1 2 and 3 on the side of the timer as shown Clears elapsed time value at power ON Time delay starts at start ON and elapsed time value or output resets at start OFF Instantaneous time delay s...

Страница 7: ...Stops delay time operation at stop ON Restarts delay time operation at stop OFF In order to have the time delay start at power ON or reset at power OFF short out the start input beforehand 1 2 3 OFF OFF ON Set the operation mode section of the DIP switches no s 1 2 and 3 on the side of the timer as shown Clears elapsed time value at power ON Time delay starts at start ON Ignores start input during...

Страница 8: ...and CE 9 Low Price All this at an affordable price to provide you with unmatched cost performance 48 1 890 48 1 890 64 5 2 539 8 pin type 11 pin type Screw terminal type Time range Operating mode Output Operating voltage Power down insurance Terminal type Part number 99 99s 999 9s 9999s 99min59s 999 9min 99h59min 999 9h 9999h Pulse input Delayed one shot OFF start flicker ON start flicker Integrat...

Страница 9: ...med out 1 Form A Open collector Min 107 ope At rated control voltage 12 to 24 V DC Max 3 W 100 to 240V AC 24V AC 50 60 Hz common Max 10 V A 100 mA 30 V DC 12 to 24 V DC Max 3 W DC type Transistor output type AC type DC type Rating Time accuracy max Contact Life Electrical Mechanical Operating conditions Rated operating voltage Rated frequency Rated power consumption Rated control capacity Time ran...

Страница 10: ...for flush mount for flush mount Mounting frame dimension is for 8 pin type 90 0 95 5 3 543 3 760 AT8 DLA1 sold separately Device installation rail 11 pin type AT8 DF11K sold separately DIN rail terminal block 8 pin type AT8 DF8K sold separately 80min 3 150min 80min 3 150min 45 0 0 6 1 772 0 024 45 0 0 6 1 772 0 024 45 0 0 6 1 772 0 024 A 48 n 2 5 0 6 0 A 1 890 n 098 024 0 A When n timers are conti...

Страница 11: ... N C 3 5 4 2 1 11 10 9 8 7 6 Reset Start Stop Lock 3 5 4 2 1 11 10 9 8 7 6 Operating voltage Reset Start Stop Lock Relay output type Transistor output type Screw terminal type 5 4 3 2 1 10 9 8 7 6 N O N C Operating voltage Reset Start Stop Lock 5 4 3 2 1 10 9 8 7 6 Reset Start Stop Lock Operating voltage Note For connecting the output leads of the transistor output type refer to 5 Transistor outpu...

Страница 12: ...h and the display returns to the normal condition 2 Setting changing the time 1 Pressing the SET LOCK key switches the set value display between T1 and T2 Display the timer T1 or T2 which is to be set or changed 2 After displaying the timer T1 or T2 which is to be set press the UP or DOWN key to change the time Checking the operation mode When the UP or DOWN key at the second digit is pressed with...

Страница 13: ...put ta Power T1 tc td T2 te tc td tf tg T2 T1 th t1 ta tb T1 t2 tg th T2 te tf T1 supply ON start flicker C Remarks and notes ON start repeating operation t1 T1 t2 T2 C PULSE Start Reset Stop Output Power supply ta tb T1 tc td T2 ta tb tc td t1 t2 T1 T1 T2 T1 T2 ON start repeating operation t1 T1 t2 T2 C INTEGRATION tb Stop Start Reset Output Power ta tc td T2 T1 tf tg tc td te t1 th T1 T2 ta tb T...

Страница 14: ...r opera tions use contacts with as short a bounce time as possible Also select a minimum input signal width of 20 ms 2 Non contact point input Connect with an open collector Use transistors whose characteristics satisfy the criteria given below VCEO 20 V min IC 20 mA min ICBO 6µA max Also use transistors with a residual volt age of less than 2 V when the transistor is on 8 pin type Screw terminal ...

Страница 15: ... load of the controlled output make sure that it is lower than the rated control capacity 4 Operation of LT4H digital timer 1 Turning on and off the power supply while operating in A2 Power on delay 2 or G Totalizing On delay will result in a timer error to be generated due to the characteristics of the internal circuitry Therefore use the start input or stop input Not related to the start input 2...

Страница 16: ...2 2 This timer employs a power supply without a transformer so the power and input signal terminals are not insulated 1 When a sensor is connected to the input circuit install double insulation on the sensor side 2 In the case of contact input use dual insulated relays etc 3 The load connected to the output con tact should have basic insulation This timer is protected with basic insula tion and ca...

Отзывы: