27 Troubleshooting
E263
Cause:
Unintended laser radiation was detected.
Remedy:
Contact our sales offices or representatives.
Applies to LP-RF, LP-RV only.
E264–E265
Cause:
• An error occurred in the laser oscillator.
• A power supply voltage error was detected in the laser oscillator.
• The signal cable or unit power cable is not connected correctly.
Remedy:
• Check the power supply.
• Check if the AC power line is affected by noise.
• Check the connection of cables and signal lines, and restart the laser
marking system.
E270–E275
Cause:
• An error occurred in the galvano scanner.
• The signal cable or unit power cable is not connected correctly.
Remedy:
• Check the power supply.
• Check if the AC power line is affected by noise.
• Check the connection of cables and signal lines, and restart the laser
marking system.
E276
Cause:
Marking data are too detailed for the scan speed configured.
Remedy:
Decrease the scan speed.
Applies to LP-GS, LP-RC only.
E277, E280–
E285
Cause:
• An error occurred in the galvano scanner.
• The signal cable or unit power cable is not connected correctly.
Remedy:
• Check the power supply.
• Check if the AC power line is affected by noise.
• Check the connection of cables and signal lines, and restart the laser
marking system.