22 Laser settings
To improve the marking quality set a larger value for this parameter. A larger value results
in a longer marking time.
• “Corners”:
Set an adequate value to optimize the appearance at the corners of a character.
If you set a smaller value, the corners of a character are rounded off. A smaller value
reduces the marking time.
If you set a larger value, it will cause burn-ins at each vector point.
(1)
(2)
(3)
(4)
(5)
(1) Small value
(2) Round corners
(3) Optimal
(4) Dark (deep) corners
(5) Large value
• “Curve”:
With this parameter, you can optimize the shape of curved line segments.
If you set a smaller value, the curved line segments are deformed. A smaller value
reduces the marking time. A larger value results in darker lines.
(1)
(2)
(3)
(4)
(5)
(1) Small value
(2) Curved line segments are deformed
(3) Optimal
(4) Dark (deep) line
(5) Large value
• “Jump”:
With this parameter, you can adjust the time until the laser starts radiating at the start
point of the line. The setting applies only if the distance to the next line is too large. The
scanner requires a certain time to reach the set position.
To improve the marking quality set a larger value for this parameter. A larger value results
in a longer marking time.
• “Pre-scan time [ms]”:
Set this parameter to improve the marking result by correcting the deformation or
reducing deep marking at the start and end points.
A larger value results in a longer marking time.
ME-NAVIS2-OP-1
233