87
7.9
PLC Link
Term
Command
Description (*)=Default
IP address and
port number of
Destination
PLC
IPPLC=xxx.xxx.xxx.xxx:
nnnn
Set the IP address and port number of Destination PLC
192.168.0.10: 9600
(*)
PLC Link
Start/Exit
PLCMODE=a
Start/Stop PLC Link function
a=0; Exit PLC link mode
(*)
a=1; Mitsubishi MELSEC Q/L SeriesUDP
MC protocol QnA compatible 3E frame(binary code)
a=2; Mitsubishi MELSEC Q/L Series 232C
MC protocol QnA compatible 3C frame(ASCII code)
a=3; OMRON SYSMAC series UDP
FINS command
a=4; OMRON SYSMAC series 232C
C mode command
a=5; Mitsubishi MELSEC FX series UDP
MC protocol A compatible1E frame(binary code)
a=6; Mitsubishi MELSEC FX series 232C
MC protocol A compatibleC frame(ASCII code)
a=7; KV series UDP
KV command mode
a=8; KEYENCE KV series 232C
KV command mode
Initial address
PLCDTA=a
Set the initial address
a=0-32767 0
(*)
Padding
character
PLCPAD=a
Set the padding character to add when the captured data
digits is odd
a=0 ( NULL[0x00] )
(*)
a=1(blank [0x20])
SYNC IN by
trigger area
PLCTRIG=a
Set the presence or absence of SYNC IN by PLC using
trigger area
a=0 Enable the SYNC IN by trigger area
(*)
a=1 Unable the SYNC IN by trigger area
Trigger area
Moniroting
time
PLCINTVL=a
Set the time interval from the monitoring completion of the
trigger area until the start of next monitoring
a=10 to 500 ; [Unit: ms] 10
(*)
Wait time of
Trigger area
monitoring time
PLCTIM=a
Set the time interval until the start of monitoring after the
trigger area monitoring is enabled.
a=5 to 20 ; [Unit: s] 10
(*)
Endian
PLCMCEND=a
Set the endian when PLCMODE=1 is set
a=0 Little endian
(*)
a=1Big endian
Satus
transmission
?PLC
Status transmission
(Settings for PLC link mode)