12
6. Display Modes
6-1 Normal State
• This product has the following three mode views:
Normal state,
Remaining battery level, and
Operation
mode.
• The
Normal state displays the operating status of the system (stopped, grid operation, back-up operation, etc.)
as well as error codes in the event of system problems.
• The
Remaining battery level displays the current remaining capacity of the storage battery.
• The
Operation mode view displays the currently selected operation mode (Maximum self-consumption mode /
Programmed charge/discharge time mode / Back-up mode).
• Press “DATA (▲)” to switch between the display modes.
*
Remaining battery level and
Operation mode views automatically return to the
Normal state after five minutes of
inactivity.
* The mode views can be switched while the system is operating or stopped.
Normal state
Remaining battery level
Operation mode
Display of the status of battery
SELF: Maximum self-consumption mode
ProG: Programmed charge/discharge time mode
bu: Back-up mode
rc: Remote control
Depending upon the battery’s
condition the battery might
not be able to be discharged
down to 0%.
The following information is displayed in the normal state:
Stopped (Grid-connected)
Stopped via User’s command.
If “ON/OFF (CANCEL)” is
pressed for one second,
the system will start the grid
operation.
Generation with
Inspection notice
System shows the Inspection
notice. Period until inspection
added.
(See 10-3)
Stopped (Back-up)
Stopped via User’s command.
”PF” will display.
If “ON/OFF (CANCEL)” is
pressed for one second, the
system will start the back-up
operation.
In operation (Back-up)
The system in back-up
operation, indicates output
power and “PF”.
If “ON/OFF (CANCEL)” is
pressed for one second, the
system will stop.
In operation (Grid-connected)
The system in grid operation
display indicates charge or
discharge power.
If “ON/OFF (CANCEL)” is
pressed for one second, the
system will stop.
Error
The system has abnormally
stopped and indicates error
mode (F/H/U/P/E) and code.