Specifications

No. digits

Measurement time range

Front reset

Input method

Part No.

7 digits

0 to 999999.9h/0 to 3999d23.9h switchable

Yes

Voltage input type (4.5 to 30 V DC)

LH2H-FE-DHK-DL-B

0 to 999h59m59s/0 to 9999h59.9m switchable

LH2H-FE-HMK-DL-B

No. digits

Measurement time range

Front reset

Input method

Part No.

7 digits

0 to 999999.9h/0 to 3999d23.9h switchable

Yes

Non-voltage input type

LH2H-F-DHK

0 to 999h59m59s/0 to 9999h59.9m switchable

LH2H-F-HMK

0 to 999999.9h/0 to 3999d23.9h switchable

Voltage input type (4.5 to 30 V DC)

LH2H-F-DHK-DL

0 to 999h59m59s/0 to 9999h59.9m switchable

LH2H-F-HMK-DL

0 to 999999.9h/0 to 3999d23.9h switchable

Free voltage input type (24 to 240 V AC/DC)

LH2H-F-DHK-FV

0 to 999h59m59s/0 to 9999h59.9m switchable

LH2H-F-HMK-FV

No. digits

Measurement time range

Front reset

Input method

Part No.

7 digits

0 to 999999.9h/0 to 3999d23.9h switchable

Yes

Voltage input type (4.5 to 30 V DC)

LH2H-F-DHK-DL-B

0 to 999h59m59s/0 to 9999h59.9m switchable

LH2H-F-HMK-DL-B

No. digits

Measurement time range

Front reset

Input method

Part No.

7 digits

0 to 999999.9h

No

Non-voltage input type

LH2H-C-H-N

0 to 9999h59.9m

LH2H-C-HM-N

1. Panel mounting type

Note) Only for installation frame type.

Type

Item

Standard type

Backlight type

Standard type

Non-voltage input

Voltage input

Free voltage type

No. digits

7 digits

External power supply

Not required (built-in battery)

Measurement time range

0 to 999999.9h/0 to 3999d23.9h (Switchable by switch)

0 to 999h59m59s/0 to 9999h59.9m (Switchable by switch)     Separate product type

Start 
input

Min. input signal width

200 ms

Input method (signal)

Non-voltage input using 

contacts or open collector 

connection

High level: 4.5 to 30 V DC

Low level: 0 to 2 V DC

High level: 

    24 to 240 V AC/DC

Low level: 

    0 to 2.4 V AC/DC

Input impedance

When shorted: 

Max. 10 k

When open: 

Max. 750 k

Approx. 4.7 k

Residual voltage

Max. 0.5 V

Reset 
input

Min. input signal width

100 ms

Input method (signal)

Non-voltage input using 

contacts or open collector 

connection

High level: 4.5 to 30 V DC

Low level: 0 to 2 V DC

Non-voltage input using 

contacts or open collector 

connection

Input impedance

When shorted: 

Max. 10 k

When open: 

Max. 750 k

Appox. 4.7 k

When shorted: 

Max. 10 k

When open: 

Max. 750 k

Residual voltage

Max 0.5 V

Max. 0.5 V

Display method

7-segment LCD

 7-segment LCD

 With green/red backlight

7-segment LCD

Breakdown voltage (initial)

Between charged and uncharged parts: 1,000 V AC for 1 minute.

Between charged and 

uncharged parts: 

2,000 V AC for 1 minute.

Insulation resistance (initial)

Min. 100 M

 (measured at 500 V DC) Measurement location same as for break down voltage.

Backlight power

24 V DC (±10%)

Protective construction (Note)

IEC Standard IP66 (only panel front: when using rubber gasket)

Accessories (Note)

Rubber gasket, mounting bracket

Battery life

10 years (at 25°C 

77°F

)

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Содержание LH2H-FE-DHK

Страница 1: ...h very easy one touch installation type and also installation frame type that uses the frame on the timer counter Choose a method that suits the application 5 Battery Replacement Easy on Environment To replace battery simply remove body for the one touch installation type and remove battery lid for the installation frame type 6 Screw Terminals Designed for Safety Built in finger protection 7 Panel...

Страница 2: ...input Voltage input Free voltage type No digits 7 digits External power supply Not required built in battery Measurement time range 0 to 999999 9h 0 to 3999d23 9h Switchable by switch 0 to 999h59m59s 0 to 9999h59 9m Switchable by switch Separate product type Start input Min input signal width 200 ms Input method signal Non voltage input using contacts or open collector connection High level 4 5 to...

Страница 3: ...h 200 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual voltage Max 0 5 V Reset input Min input signal width 10 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual power Max 0 5 V Break down voltage initial B...

Страница 4: ...ront reset button Terminal block side LCD side OFF ON Terminal block side LCD side 0 to 999999 9h 0 to 3999d23 9h Terminal block side LCD side 0 to 9999h59 9m 0 to 999h59m59s Dimensions 1 Panel mounting type External dimensions 1 One touch installation type mm inch General tolerance 1 0 039 Panel installation diagram Note When installing to a 4 5 mm 177 inch thick panel remove the rubber spacer fi...

Страница 5: ...low Use the mounting frame ATH3803 and the rubber packing ATH3804 Only installation frame type For connected installation sealed installation Only installation frame type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofing will be lost when installing repeatedly sealed installation 45 1 772 0 5 0 020 0 22 2 874 0 5 0 020 0 60 min 2 362 min 22 2 874 0 5 0 02...

Страница 6: ...ype Contact input Transistor input NPN transistor PNP transistor 2 PC board mounting type External dimensions Terminal layout and wiring diagrams General tolerance 1 0 039 mm inch PC board pattern BOTTOM VIEW General tolerance 0 1 004 Note The AXS212811K is recommended as a compatible connection socket LH2H HOUR METER 33 02 0 3 1 300 012 43 4 1 709 17 3 681 DIP switch 8 19 748 15 24 0 3 600 012 3 ...

Страница 7: ...ype Backlight connection Contact input Transistor input NPN transistor PNP transistor Reset input Start input 1 2 3 4 5 6 1 2 3 4 Reset input Start input V V 1 2 3 4 5 6 Reset input Start input V V 1 2 3 4 Green Red 24V DC 24V DC 5 6 1 2 3 4 5 6 1 Time measuring takes place when the start input is ON 2 When the elapsed measured time reaches full scale it returns to 0 and then measuring starts agai...

Страница 8: ... non voltage input 2 Be aware that the application of voltage that exceeds the voltage range of the H level to the start input terminal and the application of voltage to the reset input terminal can cause damage to the internal elements 3 Since the current flow is very small from reset input terminal 3 please use relays and switches with high contact reliability 4 When inputting a reset with an op...

Отзывы: